Geometrical and Monte Carlo projectors in 3D PET reconstruction

被引:36
|
作者
Aguiar, Pablo [1 ]
Rafecas, Magdalena [2 ]
Enrique Ortuno, Juan [3 ]
Kontaxakis, George [3 ]
Santos, Andres [3 ]
Pavia, Javier [4 ]
Ros, Domenec [5 ]
机构
[1] Univ Santiago de Compostela, Dept Fis Particulas, Complexo Hosp Univ Santiago de Compostela, Fdn IDICHUS IDIS, Santiago De Compostela, Spain
[2] Univ Valencia, CSIC, Inst Fis Corpuscular, Valencia, Spain
[3] Univ Politecn Madrid, Dept Ingn Elect, E-28040 Madrid, Spain
[4] Hosp Clin Barcelona, IDIBAPS, Serv Med Nucl, Barcelona, Spain
[5] Univ Barcelona, IDIBAPS, Fac Med, Unitat Biofis, E-08007 Barcelona, Spain
关键词
3D PET; iterative reconstruction; list-mode reconstruction; ray-tracing techniques; Monte Carlo simulation; system response matrix; ITERATIVE IMAGE-RECONSTRUCTION; SYSTEM MATRIX; SCATTER; SIMULATION; ALGORITHM; IMPLEMENTATION; MODEL; EM;
D O I
10.1118/1.3501884
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In the present work, the authors compare geometrical and Monte Carlo projectors in detail. The geometrical projectors considered were the conventional geometrical Siddon ray-tracer (S-RT) and the orthogonal distance-based ray-tracer (OD-RT), based on computing the orthogonal distance from the center of image voxel to the line-of-response. A comparison of these geometrical projectors was performed using different point spread function (PSF) models. The Monte Carlo-based method under consideration involves an extensive model of the system response matrix based on Monte Carlo simulations and is computed off-line and stored on disk. Methods: Comparisons were performed using simulated and experimental data of the commercial small animal PET scanner rPET. Results: The results demonstrate that the orthogonal distance-based ray-tracer and Siddon ray-tracer using PSF image-space convolutions yield better images in terms of contrast and spatial resolution than those obtained after using the conventional method and the multiray-based S-RT. Furthermore, the Monte Carlo-based method yields slight improvements in terms of contrast and spatial resolution with respect to these geometrical projectors. Conclusions: The orthogonal distance-based ray-tracer and Siddon ray-tracer using PSF image-space convolutions represent satisfactory alternatives to factorizing the system matrix or to the conventional on-the-fly ray-tracing methods for list-mode reconstruction, where an extensive modeling based on Monte Carlo simulations is unfeasible. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3501884]
引用
收藏
页码:5691 / 5702
页数:12
相关论文
共 50 条
  • [1] Implementation of 3D Monte Carlo PET Reconstruction Algorithm on GPU
    Wirth, A.
    Cserkaszky, A.
    Kari, B.
    Legrady, D.
    Feher, S.
    Czifrus, Sz
    Domonkos, B.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 4106 - +
  • [2] Fast projectors for iterative 3D PET reconstruction
    Cho, Sanghee
    Li, Quanzheng
    Ahn, Sangtae
    Leahy, Richard M.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1933 - 1937
  • [3] Comparison of basis functions for 3D PET reconstruction using a Monte Carlo system matrix
    Cabello, Jorge
    Rafecas, Magdalena
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (07): : 1759 - 1777
  • [4] Data rebinning and reconstruction in 3D PET/CT oncological studies: a Monte Carlo evaluation
    Rizzo, G
    Castiglioni, I
    Russo, G
    Gilardi, MC
    Panzacchi, A
    Fazio, F
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3109 - 3112
  • [5] A Monte Carlo model of noise components in 3D PET
    Castiglioni, I
    Cremonesi, O
    Gilardi, MC
    Savi, A
    Bettinardi, V
    Rizzo, G
    Bellotti, E
    Fazio, F
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2036 - 2039
  • [6] Targeted Fully 3D Monte Carlo Reconstruction in SPECT
    El Bitar, Ziad
    Petegnief, Yolande
    Hill, David
    Breton, Vincent
    Buvat, Irene
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3410 - 3413
  • [7] Assessment of a fully 3D Monte Carlo reconstruction method for preclinical PET with iodine-124
    Moreau, M.
    Buvat, I.
    Ammour, L.
    Chouin, N.
    Kraeber-Bodere, F.
    Cherel, M.
    Carlier, T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (06): : 2475 - 2491
  • [8] Accelerated Monte Carlo Scatter Correction for 3D PET.
    Holdsworth, CH
    Levin, CS
    Dahlbom, M
    Farquhar, TH
    Hoffman, EJ
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 195P - 195P
  • [9] Scatter correction techniques in 3D PET: A Monte Carlo evaluation
    Castiglioni, I
    Cremonesi, O
    Gilardi, MC
    Bettinardi, V
    Rizzo, G
    Savi, A
    Bellotti, E
    Fazio, F
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) : 2053 - 2058
  • [10] Scatter correction techniques in 3D PET: a Monte Carlo evaluation
    Castiglioni, I.
    Cremonesi, O.
    Gilardi, M.C.
    Bettinardi, V.
    Rizzo, G.
    Savi, A.
    Bellotti, E.
    Fazio, F.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 1 : 738 - 742