Fluence verification for patient specific quality assurance in ion beam therapy. Use of an a-Si flat panel detector

被引:0
|
作者
Horn, J. [1 ]
Ackermann, B. [1 ]
Brons, S. [1 ]
Lahrmann, S. [1 ]
Lampe, C. [1 ]
Ellerbrock, M. [1 ]
Jaekel, O. [2 ]
机构
[1] Heidelberg Univ Hosp, Heidelberg Ion Beam Therapy Ctr, Heidelberg, Germany
[2] German Canc Res Ctr, Dept Med Phys Radiotherapy, Heidelberg, Germany
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PO-0861
引用
收藏
页码:S438 / S438
页数:1
相关论文
共 39 条
  • [1] Investigations of a flat-panel detector for quality assurance measurements in ion beam therapy
    Hartmann, Bernadette
    Telsemeyer, Julia
    Huber, Lucas
    Ackermann, Benjamin
    Jaekel, Oliver
    Martisikova, Maria
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (01): : 51 - 68
  • [2] Electron beam verification with an a-Si flat panel electronic portal imaging device
    Aubin, M
    Faddegon, B
    Pouliot, J
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 549 - 557
  • [3] Development of a three-dimensional scintillation detector for pencil beam verification in proton therapy patient-specific quality assurance
    Frelin, Anne-Marie
    Daviau, Gautier
    Bui, My Hoang Hoa
    Fontbonne, Cathy
    Fontbonne, Jean-Marc
    Lebhertz, Dorothee
    Mainguy, Erwan
    Moignier, Cyril
    Thariat, Juliette
    Vela, Anthony
    MEDICAL PHYSICS, 2024,
  • [4] Source strength verification and quality assurance of preloaded brachytherapy needles using a CMOS flat panel detector
    Golshan, Maryam
    Spadinger, Ingrid
    Chng, Nick
    MEDICAL PHYSICS, 2016, 43 (06) : 3008 - 3018
  • [5] Demonstration of dual resolution cone beam CT technique with an a-Si/a-Se flat panel detector
    Shen, Youtao
    Zhong, Yuncheng
    Chen, Lingyun
    Lai, Chao-Jen
    Liu, Xinming
    Han, Tao
    Yi, Ying
    You, Zhicheng
    Ge, Shuaiping
    Wang, Tianpeng
    Shaw, Chris C.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [6] Trend lines on patient specific quality assurance in ion beam therapy with protons and carbon ions
    Schafasand, M.
    Kragl, G.
    Osorio, J.
    Vatnitsky, S.
    Stock, M.
    Carlino, A.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S748 - S748
  • [7] Analysis of ion beam teletherapy patient-specific quality assurance
    Liu, Xiaoli
    Deng, Yu
    Schlegel, Nicki
    Huang, Zhijie
    Moyers, Michael F.
    MEDICAL DOSIMETRY, 2019, 44 (01) : 43 - 50
  • [8] A silicon strip detector array for energy verification and quality assurance in heavy ion therapy
    Debrot, Emily
    Newall, Matthew
    Guatelli, Susanna
    Petasecca, Marco
    Matsufuji, Naruhiro
    Rosenfeld, Anatoly B.
    MEDICAL PHYSICS, 2018, 45 (02) : 953 - 962
  • [9] Characterization of a 14" x 17" flat panel detector based on ion shower doped a-Si:H PIN diodes
    Kim, HJ
    Cho, G
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 931 - 935
  • [10] Verification of patient specific quality assurance system for volumetric modulated arc therapy (VMAT)
    Amoabeng, Kwame Anokye
    Marthinsen, Anne Beate Langeland
    Hasford, Francis
    Tagoe, Samuel Nii Adu
    Anaafi, Evelyn
    HEALTH AND TECHNOLOGY, 2022, 12 (04) : 779 - 786