Revision of the well fixed Birmingham Hip Resurfacing acetabular component - Results using a novel device

被引:0
|
作者
Sandiford, Nemandra A.
Muirhead-Allwood, Sarah
Skinner, John
机构
[1] London Hip Unit, London, England
[2] Royal Natl Orthopaed Hosp, Stanmore HA7 4LP, Middx, England
来源
ACTA ORTHOPAEDICA BELGICA | 2012年 / 78卷 / 01期
关键词
hip resurfacing; revision; well fixed; acetabular cup; REMOVAL; ARTHROPLASTY;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Revision of well fixed uncemented Birmingham Hip Resurfacing (BHR) acetabular components is challenging due to their dual radius design and their stabilising fins. These features preclude use of the standard Explant (TM) device. We investigated a novel device designed to simplify revision of this socket. This prospective study included 6 male and 14 female patients. The reasons for revision, technique of revision and the scientific basis for use of this device are discussed. The sizes of revised and implanted components were measured and the amount of bone loss was calculated. Patient satisfaction was assessed as well as pre and post operative hip scores. Six men and fourteen women were included. Average ages were 58 and 62.3 years respectively. The average diameters of the explanted and re-implanted sockets were 50.7 and 54.6 mm respectively. Average time for revision of the cup was less than 5 minutes. The average duration of follow-up was 13.2 months. All patients were satisfied with their outcomes. This device simplifies the use of the Explant (TM) in removing well fixed BHR sockets with predictably minimal loss of host bone.
引用
收藏
页码:49 / 54
页数:6
相关论文
共 50 条
  • [1] Removal of the Well-Fixed Hip Resurfacing Acetabular Component
    Taylor, Paul R. P.
    Stoffel, K. K.
    Dunlop, D. G.
    Yates, P. J.
    [J]. JOURNAL OF ARTHROPLASTY, 2009, 24 (03): : 484 - 486
  • [2] Revision of well-fixed infected Birmingham hip resurfacing using the Explant system and cement mould: an useful technique
    Kapoor, Aditya
    Luscombe, John C.
    Reading, A. D.
    [J]. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2007, 17 (04): : 381 - 383
  • [3] Birmingham hip resurfacing - Is acetabular bone conserved?
    Moonot, P.
    Singh, P. J.
    Cronin, M. D.
    Kalairajah, Y. E.
    Kavanagh, T. G.
    Field, R. E.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (03): : 319 - 323
  • [4] A technique for removing a well-fixed cemented acetabular component in revision total hip arthroplasty
    Sabboubeh, A
    Al Khatib, M
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (06): : 800 - 801
  • [5] Results of Isolated Femoral Component Revision With Well-Fixed Acetabular Implant Retention
    Park, Kyung Soon
    Yoon, Taek Rim
    Song, Eun Kyoo
    Lee, Keun Bae
    [J]. JOURNAL OF ARTHROPLASTY, 2010, 25 (08): : 1188 - 1195
  • [6] Using the Explant Acetabular Cup Removal System for removing a well-fixed resurfacing cementless acetabular component
    Bhutta, M. A.
    Gambhir, A.
    [J]. ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2009, 91 (04) : 344 - 344
  • [7] Revision of a Well-fixed Brimingham Hip Resurfacing Cup-Modified Use of Explant Device
    Kumar, Narinder
    [J]. TECHNIQUES IN ORTHOPAEDICS, 2015, 30 (04) : E13 - E14
  • [8] REVISION TOTAL HIP-ARTHROPLASTY USING A CEMENTLESS ACETABULAR COMPONENT - TECHNIQUE AND RESULTS
    SILVERTON, CD
    ROSENBERG, AG
    SHEINKOP, MB
    KULL, LR
    GALANTE, JO
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (319) : 201 - 208
  • [9] Revision arthroplasty of the hip - Acetabular component
    Gollwitzer, H.
    von Eisenhart-Rothe, R.
    Holzapfel, B. M.
    Gradinger, R.
    [J]. CHIRURG, 2010, 81 (04): : 284 - +
  • [10] Results of the Birmingham Hip Resurfacing dysplasia component in severe acetabular insufficiency - A six- to 9.6-year follow-up
    McMinn, D. J. W.
    Daniel, J.
    Ziaee, H.
    Pradhan, C.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (06): : 715 - 723