Automated cerebral arteries segmentation and diameter measurement of aneurysm from MR angiograms

被引:0
|
作者
Aoyama, M
Kawashita, I
Naruse, Y
Asada, N
Awai, K
机构
[1] Hiroshima City Univ, Dept Intelligent Syst, Asaminami Ku, Hiroshima 7313194, Japan
[2] Kinki Univ, Sch Med, Dept Radiol, Higashiosaka, Osaka 577, Japan
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
An automated computerized scheme has been developed for cerebral arteries segmentation and diameter measurement of aneurysm from magnetic resonance (MR) angiograms. An MR angiogram was three dimensional image consisted of tomograms. In this method, cerebral arteries were segmented first automatically by region growing method. The cerebral arteries image was converted to two kinds of images, distance and thin line images for diameter measurement of aneurysm and blood vessel. The location of aneurysm was indicated by a user and the diameter was measured by a computer. This method can use quantitative analysis of aneurysm and blood vessel.
引用
收藏
页码:402 / 409
页数:8
相关论文
共 50 条
  • [11] AUTOMATED MEASUREMENT OF ARTERY DIAMETER FROM ARTERIOGRAMS
    KIRKEEIDE, RL
    SMALLING, RW
    GOULD, KL
    [J]. CIRCULATION, 1982, 66 (04) : 325 - 325
  • [12] Automated Semantic Segmentation and Stenosis Detection of Coronary Arteries on Invasive Coronary Angiograms Using Hypergraph Matching and Information Fusion
    Zhao, Chen
    Esposito, Michele
    Jiang, Jingfeng
    Xu, Zhihui
    Zhou, Weihua
    [J]. CIRCULATION, 2023, 148
  • [13] MEASUREMENT OF INTERNAL CAROTID-ARTERY STENOSIS FROM SOURCE MR ANGIOGRAMS
    ANDERSON, CM
    LEE, RE
    LEVIN, DL
    ALONSO, SD
    SALONER, D
    [J]. RADIOLOGY, 1994, 193 (01) : 219 - 226
  • [14] Stable Automated Segmentation of Liver MR Elastography Images for Clinical Stiffness Measurement
    Dzyubak, Bogdan
    Venkatesh, Sudhakar K.
    Glaser, Kevin
    Yin, Meng
    Talwalkar, Jayant
    Chen, Jun
    Manduca, Armando
    Ehman, Richard L.
    [J]. MEDICAL IMAGING 2013: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2013, 8672
  • [15] Artery and Vein Diameter Ratio Measurement Based on Improvement of Arteries and Veins Segmentation on Retinal Images
    Hatanaka, Yuji
    Tachiki, Hirokazu
    Ogohara, Kazunori
    Muramatsu, Chisako
    Okumura, Susumu
    Fujita, Hiroshi
    [J]. 2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 1336 - 1339
  • [16] Segmentation of cerebral vessels and aneurysms from MR angiography data
    Wilson, DL
    Noble, JA
    [J]. INFORMATION PROCESSING IN MEDICAL IMAGING, 1997, 1230 : 423 - 428
  • [17] Numerical Validation of MR-Measurement-Integrated Simulation of Blood Flow in a Cerebral Aneurysm
    Kenichi Funamoto
    Yoshitsugu Suzuki
    Toshiyuki Hayase
    Takashi Kosugi
    Haruo Isoda
    [J]. Annals of Biomedical Engineering, 2009, 37
  • [18] Numerical Validation of MR-Measurement-Integrated Simulation of Blood Flow in a Cerebral Aneurysm
    Funamoto, Kenichi
    Suzuki, Yoshitsugu
    Hayase, Toshiyuki
    Kosugi, Takashi
    Isoda, Haruo
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (06) : 1105 - 1116
  • [19] Numerical Evaluation of MR-Measurement-Integrated Simulation of Unsteady Hemodynamics in a Cerebral Aneurysm
    Funamoto, K.
    Suzuki, Y.
    Hayase, T.
    Kosugi, T.
    Isoda, H.
    [J]. 13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 2188 - +
  • [20] Automated segmentation of the individual branches of the carotid arteries in contrast-enhanced MR angiography using DeepMedic
    Magnus Ziegler
    Jesper Alfraeus
    Mariana Bustamante
    Elin Good
    Jan Engvall
    Ebo de Muinck
    Petter Dyverfeldt
    [J]. BMC Medical Imaging, 21