Low-dose, 4D myocardial perfusion with x-ray micro-CT

被引:0
|
作者
Clark, D. P. [1 ]
Badea, C. T. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Ctr In Vivo Microscopy, Durham, NC 27710 USA
关键词
micro-CT; preclinical; myocardial first-pass perfusion; cardiac function; ITERATIVE IMAGE-RECONSTRUCTION; VIEW;
D O I
10.1117/12.2254548
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray CT is widely used, both clinically and pre-clinically, for fast, high-resolution, anatomic imaging; however, compelling opportunities exist to expand its use in functional imaging applications. For instance, temporally-resolved CT data can detail cardiac motion and blood flow dynamics for one-stop cardiovascular CT imaging procedures. In previous work, we demonstrated efficient, low-dose projection acquisition and reconstruction strategies for cardiac micro-CT imaging and for multiple-injection micro-CT perfusion imaging. Here, we extend this previous work with regularization based on rank-sparse kernel regression and on filtration with the Karhunen-Loeve transform. Using a dual source, prospectively gated sampling strategy which produces an approximately uniform distribution of projections, we apply this revised algorithm to the assessment of both myocardial perfusion and cardiac functional metrics from the same set of projection data. We test the algorithm in simulations using a modified version of the MOBY mouse phantom which contains realistic perfusion and cardiac dynamics. The proposed algorithm reduces the reconstruction error by 81% relative to unregularized, algebraic reconstruction. The results confirm our ability to simultaneously solve for cardiac temporal motion and perfusion dynamics. In future work, we will apply the algorithm and sampling protocol to small animal cardiac studies.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Micro-CT of small insects by projection X-ray microscopy
    Tanisako, Akira
    Tsuruta, Susumu
    Hori, Ayumi
    Okumura, Aya
    Miyata, Chikara
    Kuzuryu, Chiaki
    Obi, Takashi
    Yoshimura, Hideyuki
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [22] Micro-CT scanner with a focusing polycapillary x-ray optic
    Jorgensen, SM
    Reyes, DA
    MacDonald, CA
    Ritman, EL
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 158 - 166
  • [23] Imaging of metallic foams using X-ray micro-CT
    Saadatfar, M.
    Garcia-Moreno, F.
    Hutzler, S.
    Sheppard, A. P.
    Knackstedt, M. A.
    Banhart, J.
    Weaire, D.
    [J]. COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2009, 344 (1-3) : 107 - 112
  • [24] Research and Development on X-ray Micro-CT System for MEMS
    Fu Jian
    Li Bin
    Zhou Zhenggan
    Wei Dongbo
    Zhou Xingyu
    [J]. ISTM/2009: 8TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, 2009, : 1947 - 1950
  • [25] Micro-CT of Pseudocneorhinus bifasciatus by projection X-ray microscopy
    Tanisako, A
    Hori, A
    Okumura, A
    Miyata, C
    Kuzuryu, C
    Obi, T
    Yoshimura, H
    [J]. JOURNAL OF ELECTRON MICROSCOPY, 2005, 54 (04): : 379 - 383
  • [26] X-ray Dose Quantification for Various Scanning Protocols with the GE eXplore 120 micro-CT
    Bretin, Florian
    Bahri, Mohamed A.
    Warnock, Geoffrey I.
    Luxen, Andre
    Seret, Alain
    Plenevaux, Alain
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3775 - 3777
  • [27] Convolutional regularization methods for 4D, x-ray CT reconstruction
    Clark, D. P.
    Badea, C. T.
    [J]. MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [28] Efficient 4D Non-local Tensor Total-Variation for Low-Dose CT Perfusion Deconvolution
    Fang, Ruogu
    Ni, Ming
    Huang, Junzhou
    Li, Qianmu
    Li, Tao
    [J]. MEDICAL COMPUTER VISION: ALGORITHMS FOR BIG DATA, 2016, 9601 : 168 - 179
  • [29] Trimodal low-dose X-ray tomography
    Zanette, I.
    Bech, M.
    Rack, A.
    Le Duc, G.
    Tafforeau, P.
    David, C.
    Mohr, J.
    Pfeiffer, F.
    Weitkamp, T.
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2012, 109 (26) : 10199 - 10204
  • [30] Adaptive Combined Denoising Based Low-dose X-ray CT Reconstruction
    Wang, Hangzhong
    Ma, Huizhu
    [J]. PROCEEDINGS OF 2012 IEEE 11TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING (ICSP) VOLS 1-3, 2012, : 1650 - 1653