Modelling of cross-flow membrane contactors: physical mass transfer processes

被引:42
|
作者
Dindore, VY
Brilman, DWF
Versteeg, GF
机构
[1] Inst Kjemisk Proc Teknol, NTNU, N-7491 Trondheim, Norway
[2] Univ Twente, Fac Chem Technol, Design & Dev Ind Proc, NL-7500 AE Enschede, Netherlands
[3] Sasol Technol Netherlands BV, NL-7522 NB Enschede, Netherlands
关键词
hollow fiber membranes; membrane contactors; CO(2) absorption; cross-flow; modelling;
D O I
10.1016/j.memsci.2004.11.017
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Traditionally, hollow fiber membrane contactors used for gas-liquid contacting were designed in a shell and tube configuration with shellside fluid flowing parallel to the fiber-side fluid, either in co-current or counter-current pattern. The primary limitations of these so-called 'parallel flow' contactors are the shell-side flow channeling or mal-distribution due to non-uniform packing of the hollow fibers, higher shellside pressure drop and relatively lower mass transfer coefficients. These limitations can be eliminated or reduced substantially by placing hollow fibers perpendicular to the flow direction. In these cross-flow membrane contactors the concentrations of both fluids vary in both directions i.e. in the direction of the flow as well as in the direction perpendicular to the flow. Hence, unlike parallel flow contactors, simple logarithmic averaging of the concentration driving force cannot be used to predict performance of the cross-flow membrane contactors. Similar chances in the driving force are also found in the cross-flow shell and tube heat exchanger. An analytical expression based on heat transfer analogy is derived in this work to describe the mass transfer in these hollow fiber cross-flow contactors. However, it was found that when the change in the volumetric flow of the compressible fluid is significant heat transfer analogy cannot be used to predict the performance of the cross-flow gas-liquid membrane contactor. Therefore, a detailed numerical model is developed to analyze the performance of the cross-flow membrane contactor in such cases. The model takes into account the shell-side mixing, change in concentration driving force in all direction as well as cascading two or more cross-flow modules to give overall co- or counter-current flow arrangement. To validate the model and developed analytical expression, carbon dioxide absorption experiments were carried out in cross-flow membrane contactor using water as a solvent. The predictions of the developed numerical model were found to be in good agreement with the experimental results. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:209 / 222
页数:14
相关论文
共 50 条
  • [22] MASS-TRANSFER EFFICIENCY OF SCREEN PACKINGS WITH GAS CROSS-FLOW
    BOGATYKH, KF
    MINNULLIN, MN
    ARTEMEV, AF
    CHEMISTRY AND TECHNOLOGY OF FUELS AND OILS, 1987, 23 (9-10) : 426 - 428
  • [23] Simulation of heat and mass transfer with cross-flow hollow fiber vacuum membrane distillation: The influence of fiber arrangement
    Liu, Jun
    Wang, Qin
    Han, Lei
    Li, Baoan
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2017, 119 : 12 - 22
  • [24] Conjugate heat and mass transfer in a cross-flow hollow fiber membrane contactor for liquid desiccant air dehumidification
    Zhang, Li-Zhi
    Huang, Si-Min
    Pei, Li-Xia
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (25-26) : 8061 - 8072
  • [25] HYDRAULIC PERMEABILITY, MASS-TRANSFER, AND RETENTION OF PEGS IN CROSS-FLOW ULTRAFILTRATION THROUGH A SYMMETRICAL MICROPOROUS MEMBRANE
    PRADANOS, P
    ARRIBAS, JI
    HERNANDEZ, A
    SEPARATION SCIENCE AND TECHNOLOGY, 1992, 27 (15) : 2121 - 2142
  • [26] Transient performance of coupled heat and mass transfer in cross-flow hollow fiber membrane module for air dehumidification
    Zhang, Ning
    Yin, Shao-You
    Yang, Hong-Hai
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 108 : 190 - 199
  • [27] Experimental Study of Heat and Mass Transfer Coefficients in a Cross-Flow Heating Tower
    Zhang, Xiao-Song (rachpe@seu.edu.cn), 2017, Science Press (38):
  • [28] INFLUENCE OF INCREASED MASS CROSS-FLOW ON HEAT-TRANSFER DURING VAPORIZATION
    MILITZER, KE
    ZAHN, M
    CHEMISCHE TECHNIK, 1977, 29 (11): : 646 - 646
  • [29] Experimental study of heat and mass transfer characteristics in a cross-flow heating tower
    Huang, Shifang
    Lv, Zhenyu
    Liang, Caihua
    Zhang, Xiaosong
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 77 : 116 - 127
  • [30] Three-dimensional turbulent flow and conjugate heat and mass transfer in a cross-flow hollow fiber membrane bundle for seawater desalination
    Li, Guo-Pei
    Zhang, Li-Zhi
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 120 : 328 - 341