X-ray scatter in a clinical CBCT system

被引:0
|
作者
Li, H. [1 ]
Mohan, R. [1 ]
Zhu, X. [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
10.1118/1.2760519
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the magnitude of x‐ray scatter, and to evaluate the effects of scatter related artifacts on a clinical cone‐beam CT (CBCT) system. Method and Materials: The scattered to primary energy fluence ratio (SPR) was measured as a function of cone angle using lead disks of 3 mm thickness placed on a stack of solid water phantom with thickness of 0, 5, 10, 18, 29 cm, representing air (couch only), extremity, chest, abdomen, and pelvis, respectively. The measurement was repeated with and without bowtie filter in the x‐ray beam. The variation of scatter was evaluated by comparing the measurements with the lead disk placed at different positions in the x‐ray field. The effectiveness of increase air‐gap to reduce SPR was also tested using thickness of 18 and 29 cm of solid water phantom. The air‐gap was increased from the minimum allowance of a clinical scan of about 30 cm to the maximum achievable approximately 42 cm for 18 cm phantom and 38 cm for 29 cm phantom. Results: SPR of the CBCT system increases with thickness of the phantom, from 8% for couch only, to 64% for 29 cm depth of solid water phantom at the maximum cone angle with bowtie. For the depth of 29 cm, SPR varies from 26% at 2° cone angle to 64% at 12° with bowtie. The scatter fluence at different locations of the x‐ray field remains constant without a bowtie filter, indicating the scatter kernel is space invariant. However, when using the half‐fan geometry, the scatter increases with fan angles. As the air‐gap increases, the SPR decreases almost linearly. Conclusion: In CBCT imaging, scatter degrades image quality, especially for large body size, even with an anti‐scatter grid. Scatter removal or correction is necessary for quantitative CBCT measurements. Conflict of Interest: Supported by Varian. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2371 / 2371
页数:1
相关论文
共 50 条
  • [41] X-RAY REFLECTOMETER FOR OPTICAL EFFICIENCY AND SCATTER MEASUREMENTS
    REYNOLDS, JM
    FIELDS, SA
    HOLLAND, RL
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1978, 49 (12): : 1667 - 1669
  • [42] X-Ray Scatter Reduction in Tomosynthesis Imaging of the Breast
    Sechopoulos, I.
    Feng, S.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [43] IMPROVED SCATTER SHIELD FOR PICKER X-RAY DIFFRACTOMETER
    KATZ, G
    BLUMENTHAL, R
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1971, 42 (04): : 519 - +
  • [44] THE EFFECTS OF SCATTER IN X-RAY COMPUTED-TOMOGRAPHY
    JOSEPH, PM
    SPITAL, RD
    [J]. MEDICAL PHYSICS, 1982, 9 (04) : 464 - 472
  • [45] Analysis Model of X-ray Coherent Scatter Images
    Liu, Taihui
    Li, Yanhong
    Liu, Jingxin
    Qiao, Shuang
    Song, Jianzhong
    [J]. 2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 102 - 105
  • [46] SCATTER FIELD INFLUENCE ON X-RAY GRID CHARACTERIZATION
    BERNSTEIN, H
    MUNTZ, EP
    [J]. PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1982, 347 : 198 - 210
  • [47] On scatter in megavoltage x-ray transmission imaging (in English)
    Spies, L
    [J]. MEDICAL PHYSICS, 2000, 27 (03) : 624 - 624
  • [48] X-Ray Scatter Estimation Using Deep Splines
    Roser, Philipp
    Birkhold, Annette
    Preuhs, Alexander
    Syben, Christopher
    Felsner, Lina
    Hoppe, Elisabeth
    Strobel, Norbert
    Kowarschik, Markus
    Fahrig, Rebecca
    Maier, Andreas
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (09) : 2272 - 2283
  • [49] Radiochromic film dosimetry for x-ray scatter imaging
    Dydula, Christopher
    Beaton-Green, Lindsay A.
    Johns, Paul C.
    Wardlaw, Graeme
    [J]. MEDICAL PHYSICS, 2021, 48 (08) : 4695 - 4695
  • [50] The principles and effectiveness of X-ray scatter correction software for diagnostic X-ray imaging: A scoping review
    Sayed, Mohammad
    Knapp, Karen M.
    Fulford, Jon
    Heales, Christine
    Alqahtani, Saeed J.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2023, 158