X-ray scatter in a clinical CBCT system

被引:0
|
作者
Li, H. [1 ]
Mohan, R. [1 ]
Zhu, X. [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
10.1118/1.2760519
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the magnitude of x‐ray scatter, and to evaluate the effects of scatter related artifacts on a clinical cone‐beam CT (CBCT) system. Method and Materials: The scattered to primary energy fluence ratio (SPR) was measured as a function of cone angle using lead disks of 3 mm thickness placed on a stack of solid water phantom with thickness of 0, 5, 10, 18, 29 cm, representing air (couch only), extremity, chest, abdomen, and pelvis, respectively. The measurement was repeated with and without bowtie filter in the x‐ray beam. The variation of scatter was evaluated by comparing the measurements with the lead disk placed at different positions in the x‐ray field. The effectiveness of increase air‐gap to reduce SPR was also tested using thickness of 18 and 29 cm of solid water phantom. The air‐gap was increased from the minimum allowance of a clinical scan of about 30 cm to the maximum achievable approximately 42 cm for 18 cm phantom and 38 cm for 29 cm phantom. Results: SPR of the CBCT system increases with thickness of the phantom, from 8% for couch only, to 64% for 29 cm depth of solid water phantom at the maximum cone angle with bowtie. For the depth of 29 cm, SPR varies from 26% at 2° cone angle to 64% at 12° with bowtie. The scatter fluence at different locations of the x‐ray field remains constant without a bowtie filter, indicating the scatter kernel is space invariant. However, when using the half‐fan geometry, the scatter increases with fan angles. As the air‐gap increases, the SPR decreases almost linearly. Conclusion: In CBCT imaging, scatter degrades image quality, especially for large body size, even with an anti‐scatter grid. Scatter removal or correction is necessary for quantitative CBCT measurements. Conflict of Interest: Supported by Varian. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2371 / 2371
页数:1
相关论文
共 50 条
  • [1] Spatial Frequency Spectrum of the X-Ray Scatter Distribution in CBCT
    Bootsma, G.
    Verhaegen, F.
    Jaffray, D.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [2] The effects of compensator and imaging geometry on the distribution of x-ray scatter in CBCT
    Bootsma, G. J.
    Verhaegen, F.
    Jaffray, D. A.
    [J]. MEDICAL PHYSICS, 2011, 38 (02) : 897 - 914
  • [3] Spatial frequency spectrum of the x-ray scatter distribution in CBCT projections
    Bootsma, G. J.
    Verhaegen, F.
    Jaffray, D. A.
    [J]. MEDICAL PHYSICS, 2013, 40 (11)
  • [4] Scatter Correction for X-ray Imaging Using Primary Modulation: A Phantom Study for CBCT
    Zhu, Lei
    Bennett, Robert
    Fahrig, Rebecca
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1372 - +
  • [5] System tuning for x-ray scatter measurements in explosive detection
    Speller, R
    Malden, C
    Ng, E
    Horrocks, J
    Luggar, R
    Lacey, R
    [J]. PHYSICS-BASED TECHNOLOGIES FOR THE DETECTION OF CONTRABAND, 1997, 2936 : 191 - 200
  • [6] Multimodal x-ray scatter imaging
    Bunk, O.
    Bech, M.
    Jensen, T. H.
    Feidenhans'l, R.
    Binderup, T.
    Menzel, A.
    Pfeiffer, F.
    [J]. NEW JOURNAL OF PHYSICS, 2009, 11
  • [7] X-RAY SCATTER REMOVAL BY DECONVOLUTION
    SEIBERT, JA
    BOONE, JM
    [J]. MEDICAL PHYSICS, 1986, 13 (05) : 782 - 782
  • [8] X-ray scatter in projection radiography
    Ylimaula, Satu
    Rasanen, Lasse
    Hurskainen, Miia
    Peuna, Arttu
    Julkunen, Petro
    Nieminen, Miika Tapio
    Hanni, Matti
    [J]. RADIATION PROTECTION DOSIMETRY, 2024, 200 (02) : 120 - 129
  • [9] X-RAY SCATTER REMOVAL BY DECONVOLUTION
    SEIBERT, JA
    BOONE, JM
    [J]. MEDICAL PHYSICS, 1988, 15 (04) : 567 - 575
  • [10] Independent component analysis for removing x-ray scatter in x-ray images
    Chen, Yen-Wei
    Han, Xianhua
    Oikawa, Shiro
    Fujita, Akinori
    [J]. 2007 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2007, : 2327 - +