Efficiency response of an aged PIPS detector used in high-resolution alpha-particle spectrometry

被引:6
|
作者
Huynh Nguyen Phong Thu [1 ,2 ]
Nguyen Van Thang [1 ]
Le Cong Hao [1 ,2 ]
机构
[1] Univ Sci, VNU HCM, Nucl Tech Lab, Linh Trung Campus Linh Trung Ward, Ho Chi Minh City, Vietnam
[2] Univ Sci, VNU HCM, Fac Phys & Engn Phys, Dept Nucl Phys & Nucl Engn, 227 Nguyen Van Cu St,Dist 5, Ho Chi Minh City, Vietnam
关键词
Alpha-particle spectrometry; Counting efficiency; Resolution; PIPS detector; Dead layer; SRIM; DEAD LAYER; ELECTRODEPOSITION; SIMULATION; ACTINIDES; THORIUM; URANIUM; WATER;
D O I
10.1016/j.nima.2018.08.044
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The experimental characterization of an aged PIPS detector used in an alpha-particle spectrometry is performed using a standard mixed source of U-238, U-234, Pu-239, and Am-241. The variations in the detector efficiency and resolution (FWHM) at the main energy lines of the U-238, U-234, Pu-239, and Am-241 source were investigated at all possible source-detector distances under chamber air pressure of similar to 1.33 Pa. Finding shows that on average, the counting efficiency data obtained from measurements are lower than those obtained by theoretical data and Monte Carlo simulation (SOLANG and AASI) methods. A combination of polymeric strippable coating and both traditional wiping and cleaning method for the detector decontamination works only show a significant reduction in the background activity. The counting efficiency improvement process by an increase of the higher voltages within the recommended range results in a good agreement in the counting efficiency comparison and a slight decrease of the detector dead layer thickness. Novel method to evaluate the dead layer thickness for PIPS detector via the variations in experimental energy loss with respect source to detector distance using alpha standard sources of (PU)-P-242 has been proposed. This method can help to predict a default dead layer thickness value which will be as close as it was originally, is less than 50 nm from the manufacturer.
引用
收藏
页码:128 / 135
页数:8
相关论文
共 50 条
  • [1] High-resolution alpha-particle spectrometry of 238U
    Pomme, S.
    Garcia-Torano, E.
    Marouli, M.
    Crespo, M. T.
    Jobbagy, V.
    Van-Ammel, R.
    Paepen, J.
    Stroh, H.
    [J]. APPLIED RADIATION AND ISOTOPES, 2014, 87 : 315 - 319
  • [2] Activity determination without tracers in high-resolution alpha-particle spectrometry
    Roy Pöllänen
    Teemu Siiskonen
    Sakari Ihantola
    Harri Toivonen
    Andreas Pelikan
    Kenneth Inn
    Jerome La Rosa
    Balazs Bene
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2011, 290 : 551 - 555
  • [3] Activity determination without tracers in high-resolution alpha-particle spectrometry
    Pollanen, Roy
    Siiskonen, Teemu
    Ihantola, Sakari
    Toivonen, Harri
    Pelikan, Andreas
    Inn, Kenneth
    La Rosa, Jerome
    Bene, Balazs
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 290 (03) : 551 - 555
  • [4] High-resolution alpha-particle spectrometry of the 230U decay series
    Marouli, M.
    Pomme, S.
    Paepen, J.
    Van Ammel, R.
    Jobbagy, V.
    Dirican, A.
    Suliman, G.
    Stroh, H.
    Apostolidis, C.
    Abbas, K.
    Morgenstern, A.
    [J]. APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 2270 - 2274
  • [5] High-resolution alpha-particle spectrometry using silicon carbide semiconductor detectors
    Ruddy, Frank H.
    Seidel, John G.
    Chen, Haoqian
    Dulloo, Abdul R.
    Ryu, Sei-Hyung
    [J]. 2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1231 - 1235
  • [6] Diamond detector for alpha-particle spectrometry
    Duenas, J. A.
    de la Torre Perez, J.
    Martin Sanchez, A.
    Martel, I.
    [J]. APPLIED RADIATION AND ISOTOPES, 2014, 90 : 177 - 180
  • [7] HIGH-RESOLUTION ALPHA-PARTICLE SPECTROSCOPY USING CR-39 PLASTIC TRACK DETECTOR
    FEWS, AP
    HENSHAW, DL
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 197 (2-3): : 517 - 529
  • [8] HIGH-RESOLUTION ALPHA-PARTICLE SPECTROSCOPY USING CR-39 PLASTIC TRACK DETECTOR
    FEWS, AP
    HENSHAW, DL
    [J]. NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1981, 5 (04): : 387 - 387
  • [9] HIGH-RESOLUTION ALPHA-PARTICLE SPECTROSCOPY USING CR-39 PLASTIC TRACK DETECTOR
    FEWS, AP
    HENSHAW, DL
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 223 (2-3): : 609 - 616
  • [10] An SiC/GaN Detector/Front-End Detection System for High-Resolution Alpha-Particle Spectroscopy
    Pullia, A.
    Bertuccio, G.
    Maiocchi, D.
    Caccia, S.
    Zocca, F.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (06) : 3736 - 3740