Absolute Measurement and Relative Measurement of Ultrasonic Nonlinear Parameters

被引:25
|
作者
Kim, Jongbeom [1 ]
Song, Dong-Gi [1 ]
Jhang, Kyung-Young [2 ]
机构
[1] Hanyang Univ, Dept Mech Convergence Engn, Seoul, South Korea
[2] Hanyang Univ, Sch Mech Engn, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Al6061-T6; absolute parameter; fused silica; relative parameter; ultrasonic nonlinear parameter; ACOUSTIC HARMONIC-GENERATION; TRANSDUCER; AMPLITUDES; SOLIDS; WAVES;
D O I
10.1080/09349847.2016.1174322
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The ultrasonic nonlinear parameter is measured from the amplitudes of the harmonic frequency components generated during the propagation of ultrasonic waves in a material. There are two definitions for this parameter: absolute and relative. The absolute parameter is defined by the displacement amplitude; however, it is difficult to measure because of the very small displacement amplitude of the harmonic components. Conversely, the relative parameter is defined by the amplitude of the detected signal, regardless of displacement. Many researchers use the relative parameter because it is easier to measure, although it is only available for a relative comparison of different materials. However, it has not yet been verified that the ratio of the relative parameters between two materials is identical to that of the absolute parameters. In this study, we make it clear that the ratio of the relative parameters is inherently not identical to that of the absolute parameters, but that they can be identical to each other by compensating for material-dependent differences, such as detection-sensitivity and wavenumber. For verification, the absolute and relative parameters were measured for two different materials. The results showed that the ratios of absolute and relative parameters were in good agreement after compensation.
引用
收藏
页码:211 / 225
页数:15
相关论文
共 50 条
  • [31] On Absolute Measurement
    Dorsey, N. Ernest
    Eisenhart, Churchill
    SCIENTIFIC MONTHLY, 1953, 77 : 103 - 109
  • [32] MEASUREMENT OF ULTRASONIC NONLINEAR PARAMETER IN EXCISED FAT TISSUES
    ERRABOLU, RL
    SEHGAL, CM
    BAHN, RC
    GREENLEAF, JF
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1988, 14 (02): : 137 - 146
  • [33] Ultrasonic nonlinear parameter measurement: critical investigation of the instrumentation
    Haumesser, L.
    Fortineau, J.
    Parenthoine, D.
    Goursolle, T.
    Meulen, F. Vander
    ULTRASONIC WAVE PROPAGATION IN NON HOMOGENEOUS MEDIA, 2009, 128 : 387 - 397
  • [34] Measurement of dynamic parameters of frozen soil by ultrasonic techniques
    Wang, DY
    Zhu, YL
    Peng, WW
    Zhao, SP
    Li, HP
    PERMAFROST, VOLS 1 AND 2, 2003, : 1207 - 1210
  • [35] ULTRASONIC MEASUREMENT OF NONLINEARITY PARAMETERS OF COPPER SINGLE CRYSTALS
    GAUSTER, WB
    BREAZEALE, MA
    PHYSICAL REVIEW, 1968, 168 (03): : 655 - +
  • [36] ULTRASONIC MEASUREMENT OF TEMPERATURE DEPENDENCE OF NONLINEARITY PARAMETERS OF COPPER
    PETERS, RD
    BREAZEALE, MA
    PARE, VK
    PHYSICAL REVIEW B-SOLID STATE, 1970, 1 (08): : 3245 - +
  • [37] Ultrasonic measurement method of atmospheric meteorological and turbulence parameters
    Zhou Menglian
    Liu Jingru
    Cai Yue
    Yao Dongsheng
    Cheng Deyan
    Proceedings of the First International Symposium on Test Automation & Instrumentation, Vols 1 - 3, 2006, : 895 - 898
  • [38] Absolute measurement of ultrasonic non-linearity parameter at contact interface
    Yuan, Maodan
    Lee, Taekgyu
    Kang, To
    Zhang, Jianhai
    Song, Sung-Jin
    Kim, Hak-Joon
    NONDESTRUCTIVE TESTING AND EVALUATION, 2015, 30 (04) : 356 - 372
  • [39] MEASUREMENT SPECTRA AND ABSOLUTE CONTINUOUS MEASUREMENT
    MEYER, Y
    STUDIA MATHEMATICA, 1968, 30 (01) : 87 - &
  • [40] ULTRASONIC COUPLED-SHUTTERS EXPERIMENT FOR MEASUREMENT OF THE EARTHS ABSOLUTE VELOCITY
    MARINOV, S
    SPECULATIONS IN SCIENCE AND TECHNOLOGY, 1978, 1 (03) : 235 - 238