Measurement of targeting accuracy in focused ultrasound functional neurosurgery

被引:35
|
作者
Moser, David [1 ]
Zadicario, Eyal [2 ]
Schiff, Gilat [2 ]
Jeanmonod, Daniel [1 ]
机构
[1] Ctr Ultrasound Funct Neurosurg, CH-4500 Solothurn, Switzerland
[2] InSightec Ltd, Tirat Carmel, Israel
关键词
anterior commissure; posterior commissure; stereotactic atlas; targeting accuracy; thalamoventricular border; transcranial magnetic resonance-guided focused ultrasound;
D O I
10.3171/2011.10.FOCUS11246
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Israel The object of this study was to describe a method of measuring targeting accuracy in functional neurosurgery using MR imaging and the Stereotactic Atlas of the Human Thalamus and Basal Ganglia. This method should be useful for any functional procedure using these tools or similar ones, and is described here in the specific context of focused ultrasound surgery. The authors describe the atlas coordinate system used, the different relevant targeting and accuracy definitions, the tools used, the intraoperative target determination, the postoperative target reconstructions, and the calculation of the therapeutic lesion volume. The proposed method has been applied to the specific situation of measuring targeting accuracy in focused ultrasound functional neurosurgery. The authors found mean absolute global targeting accuracies between 0.54 and 0.72 mm (SDs between 0.34 and 0.42 mm), with 85% of measured coordinates within 1 mm. The proposed method may be particularly useful in the context of functional neurosurgical procedures implying therapeutic ablations, be they through radiofrequency, focused ultrasound, or any other technique. This method allows an ongoing control of the targeting precision, a basic requirement in any functional neurosurgical procedure. (http://thejns.org/doi/abs/10.3171/2011.10.FOCUS11246)
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Focused Ultrasound for Ablation in Neurosurgery-Present Use and Future Directions
    Yoh, Nina
    De Los Santos, Genesis
    Tazhibi, Masih
    Englander, Zachary
    Lignelli-Dipple, Angela
    Wu, Cheng-Chia
    Baltuch, Gordon
    APPLIED RADIOLOGY, 2023, 52 (04) : 14 - 19
  • [32] Effect of High-Intensity Focused Ultrasound on Daily Practice in Neurosurgery
    Ulrich, Nils H.
    Bozinov, Oliver
    WORLD NEUROSURGERY, 2010, 74 (01) : 12 - 13
  • [33] High-intensity focused ultrasound: past, present, and future in neurosurgery
    Quadri, Syed A.
    Waqas, Muhammad
    Khan, Inamullah
    Khan, Muhammad Adnan
    Suriya, Sajid S.
    Farooqui, Mudassir
    Fiani, Brian
    NEUROSURGICAL FOCUS, 2018, 44 (02)
  • [34] Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
    Li, Ke
    Bai, Jingfeng
    Chen, Yazhu
    Ji, Xiang
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (145):
  • [35] Variations in targeting techniques of focused ultrasound for use in neuromodulation
    Spivak, Norman M.
    Kuhn, Taylor P.
    BRAIN STIMULATION, 2019, 12 (06) : 1595 - 1596
  • [36] MEASUREMENT OF MIXING IN POLYMER MELTS BY FOCUSED ULTRASOUND
    DOHNER, J
    ERWIN, L
    PLASTICS ENGINEERING, 1984, 40 (03) : 50 - 50
  • [37] American Society for Stereotactic and Functional Neurosurgery Position Statement on Magnetic Resonance-Guided Focused Ultrasound for the Management of Essential Tremor
    Pouratian, Nader
    Baltuch, Gordon
    Elias, W. Jeff
    Gross, Robert
    NEUROSURGERY, 2020, 87 (02) : E126 - E129
  • [38] The potential applications of high-intensity focused ultrasound (HIFU) in vascular neurosurgery
    Serrone, Joseph
    Kocaeli, Hasan
    Mast, T. Douglas
    Burgess, Mark T.
    Zuccarello, Mario
    JOURNAL OF CLINICAL NEUROSCIENCE, 2012, 19 (02) : 214 - 221
  • [39] MEASUREMENT OF MIXING IN POLYMER MELTS BY FOCUSED ULTRASOUND
    ERWIN, L
    DOHNER, J
    POLYMER ENGINEERING AND SCIENCE, 1984, 24 (16): : 1277 - 1282
  • [40] FUNCTIONAL EFFECTS OF FOCUSED ULTRASOUND ON MAMALIAN NERVES
    YOUNG, RR
    SCIENCE, 1961, 134 (348) : 1521 - &