Experimental study of fire plume temperature and radiant heat flux of a horizontal jet flame impinging a wall

被引:8
|
作者
Wang, Chen [1 ]
Ji, Jie [1 ]
机构
[1] Univ Sci & Technol China, State Key Lab Fire Sci, JinZhai Rd 96, Hefei 230026, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Horizontal jet flame; Impinging the wall; Fire plume temperature; Radiant heat flux; CEILING JET; UNINTENDED RELEASES; VELOCITY DISTRIBUTIONS; MERGING BEHAVIORS; DIFFUSION FLAMES; BARRIER WALLS; TUNNEL; SPREAD; MODEL; APPROXIMATION;
D O I
10.1016/j.firesaf.2022.103550
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Jet fire usually appears in natural gas fuel production and transportation due to uncontrolled fuel leakage. Jet fire can impinge on equipment surface or a passive firewall to make the fire plume temperature and the radiant heat flux complex. Experiments of a horizontal jet flame impinging a wall under various fuel initial velocity and nozzle-wall spacing were carried out. Results show the changing relationship between the amount of oxygen required and the actual amount of oxygen results in the different temperature distribution of fire plume on the wall surface. A new dimensionless number is proposed to determine the maximum rising temperature of fire plume on the wall surface. The fire plume volume and the distance between a certain position and fire plume within the viewing angle range of the radiometer, as two important factors, can explain the trend of radiant heat flux well. A virtual total radiant heat flux Q(v,tr) received by a core area of the horizontal jet fire impinging the wall is estimated. Q(v,tr) firstly increases, and then decreases with Z(n-w) increasing. Increasing fire plume volume and increasing distance between the wall and the fire plume have the opposite effect on controlling Q(v,tr) together.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Experimental study of the temperature profile induced by the tunnel wall fire plume at various source-ceiling heights
    Fang, Xiang
    Huang, Yajun
    Ren, Fei
    Zhang, Hao
    Li, Congcong
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2024, 60
  • [43] Experimental and computational study of heat transfer and flow structure of slotted impinging jet
    Illyas, S. Mohamed
    Bapu, B. R. Ramesh
    Manokar, A. Muthu
    [J]. JOURNAL OF THERMAL ENGINEERING, 2024, 10 (05): : 1275 - 1291
  • [44] Experimental study on flame radiant heat flux from two heptane storage pools and its application to estimating safety distance
    Wan, Huaxian
    Gao, Zihe
    Ji, Jie
    Zhang, Yongming
    [J]. ENERGY, 2019, 182 : 11 - 20
  • [45] Experimental Study of Heat Transfer from Impinging Jet with Upstream and Downstream Crossflow
    Thibault, Daniel
    Fenot, Matthieu
    Lalizel, Gildas
    Dorignac, Eva
    [J]. HEAT TRANSFER RESEARCH, 2010, 41 (08) : 889 - 900
  • [46] An experimental study of fluid in an impinging mechanics and heat transfer slot jet flow
    Narayanan, V
    Seyed-Yagoobi, J
    Page, RH
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (8-9) : 1827 - 1845
  • [47] Experimental study on the condensation and heat transfer of impinging steam jet on the water surface
    Cha, Jinho
    Kim, Taejoon
    Lim, Seungho
    Lee, Haneol
    Shin, Weon Gyu
    [J]. ANNALS OF NUCLEAR ENERGY, 2019, 133 : 458 - 468
  • [48] Quenching distance, wall heat flux and CO/NO thermochemical states in the wall vicinity of laminar premixed biogas-hydrogen impinging flame
    Wei, Zhilong
    Liu, Hu
    Chen, Zhenbin
    Liu, Zihao
    Zhen, Haisheng
    [J]. FUEL, 2022, 307
  • [49] Experimental study of the effect of a radiant tube on the temperature distribution in a horizontal heating furnace
    Xu, H. T.
    Liao, X. W.
    Qu, Z. G.
    Li, Y. Z.
    Chen, J.
    [J]. APPLIED THERMAL ENGINEERING, 2017, 113 : 1 - 7
  • [50] Experimental study on the ceiling jet characteristics caused by carriage fire in an inclined tunnel: Temperature distribution and flame extension
    Xu, Tong
    Tang, Fei
    Zhang, Jianping
    [J]. PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2024, 40 (1-4)