Study on the performance of open-circuit failure gas discharge tube under the context of DC short-circuit

被引:3
|
作者
Zheng, Chuanxiao [1 ]
Lu, Hao [1 ,2 ]
Xu, Yongzhong [2 ]
Wang, Yanlin [3 ]
机构
[1] Xinjiang Univ, Sch Elect Engn, Urumqi 830047, Peoples R China
[2] Xinjiang Univ, Sch Future Technol, Urumqi 830047, Peoples R China
[3] Shenzhen Ruilongyuan Elect Co Ltd, Shenzhen 818000, Peoples R China
基金
中国国家自然科学基金;
关键词
Short-circuit current; Gas discharge tube; Response arc extinguishing time;
D O I
10.1016/j.epsr.2022.108777
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Protective devices are used at every single port of electrical equipment, such as gas discharge tube(GDT), metal oxide varistors(MOV), and transient voltage suppressors diodes(TVS). These devices are capable to absorb lightning, surge, static electricity and other burst waves by directly spanning across both ends of the circuit or grounding mode. When the protective devices overabsorb these burst waves, short-circuit failure will result. The short-circuit failure of protective devices is one of the potential hazards that would cause combustion. In order to avoid the fault combustion of GDT caused by short-circuit, an open-circuit failure gas discharge tube (OGDT) with the capacity of open-circuit failure is proposed by improving the existing GDT with a high and low temperature sealing solder. This paper focuses on exploring the structure and working mechanism of OGDT, with the open-circuit failure response arc extinguishing time of the OGDT measured by coupling the DC power supply with an 8/20 mu s impact current generator. The impact of short-circuit current and DC voltage on OGDT response arc extinguishing time is analyzed by conducting experiments and the effect of OGDT is verified by adjusting the area of low temperature weld. The results show that with the rise of short-circuits current, the open-circuit response arc extinguishing time of OGDT first decreases and then increases. A larger area of the low-temperature welding solder leads to a shorter the response arc extinguishing time. Besides, the higher the applied DC voltage, the shorter the response arc extinguishing time. When the short-circuit current reaches 10 A, the optimal response arc extinguishing time is 300 ms. When the short-circuit current falls below 25 A, the response arc extinguishing time of OGDT can reach a lower level than 1000 ms. The OGDT open-circuit failure action screen is captured by a high-speed camera to verify its outcome. The high-speed camera captures the OGDT open-circuit failure and excision failure at 300 ms, which is consistent with the experimental waveform results. The research results provide practical guidance on the selection of OGDT.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Effect of doping on the short-circuit current and open-circuit voltage of polymer solar cells
    Zhao, Yong
    Liang, Chunjun
    Sun, Mengjie
    Liu, Qian
    Zhang, Fujun
    Li, Dan
    He, Zhiqun
    JOURNAL OF APPLIED PHYSICS, 2014, 116 (15)
  • [22] OPEN-CIRCUIT TO SHORT-CIRCUIT SWITCHING - METHOD FOR LIFETIME MEASUREMENT IN SOLAR-CELLS
    DHARIWAL, SR
    BASU, N
    GADRE, R
    ELECTRONICS LETTERS, 1979, 15 (15) : 456 - 458
  • [23] THEOREM ON OPEN-CIRCUIT AND SHORT-CIRCUIT DRIVING-POINT IMPEDANCE MATRICES OF A PASSIVE MULTIPORT
    IMAMURA, K
    OONO, Y
    ELECTRONICS & COMMUNICATIONS IN JAPAN, 1974, 57 (02): : 54 - 62
  • [24] Design of Pole Detection Coils for Open-Circuit and Short-Circuit Faults in Multiphase Brushless Exciter
    Sun Y.
    Du W.
    Gui L.
    Duan X.
    Hao L.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2022, 37 (14): : 3542 - 3554
  • [25] Offline Fault Diagnosis for 2-Level Inverter: Short-Circuit and Open-Circuit Detection
    Hyon, Byong Jo
    Hwang, Dae Yeon
    Jang, Pooreum
    Noh, Yong-Su
    Kim, Jin-Hong
    ELECTRONICS, 2024, 13 (09)
  • [26] A Superlattice Solar Cell With Enhanced Short-Circuit Current and Minimized Drop in Open-Circuit Voltage
    Wang, Yunpeng
    Wen, Yu
    Sodabanlu, Hassanet
    Watanabe, Kentaroh
    Sugiyama, Masakazu
    Nakano, Yoshiaki
    IEEE JOURNAL OF PHOTOVOLTAICS, 2012, 2 (03): : 387 - 392
  • [27] Other origins for the fluorescence modulation of single dye molecules in open-circuit and short-circuit devices
    Teguh, Jefri S.
    Kurniawan, Michael
    Wu, Xiangyang
    Sum, Tze Chien
    Yeow, Edwin K. L.
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2013, 15 (01) : 90 - 93
  • [28] A Novel Method for Measuring the Open-circuit Loss and Short-circuit Loss of Distribution Transformers Online
    Li Xia
    Chen Min-You
    Cheng Shan
    MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION IV, PTS 1 AND 2, 2012, 128-129 : 473 - 477
  • [29] Fault Tolerant Active Neutral Point Clamped Inverter: Short-Circuit and Open-Circuit Failures
    de Lacerda, Antonio Isaac L.
    da Silva, Edison Roberto C.
    2015 IEEE 24TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2015, : 1068 - 1073
  • [30] Universal Short-Circuit and Open-Circuit Fault Protection and Detection for a Power Converters Power Device
    Brown, Buck F., III
    Zhang, Zheyu
    Enslin, Johan H.
    Wan, Cheng
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2025, 61 (01) : 527 - 536