Optimization of fiber optic probe distance for biomedical spectroscopy

被引:0
|
作者
Wang, Bowen [1 ]
Tang, Yan [2 ]
Zhang, Xiaolei [2 ]
Fan, Shuzhen [2 ]
机构
[1] Hosp Shandong Univ, 91 Shanda Bei Rd, Jinan 250100, Peoples R China
[2] Shandong Univ, Sch Informat Sci & Engn, Jinan 250100, Peoples R China
关键词
biomedical spectroscopy; fiber optic probes; probe distance; reflectance; fluorescence; Raman; COLLECTION EFFICIENCY; CANCER; TISSUE;
D O I
10.1117/12.871675
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present a theoretical model to maximize the illumination and collection efficiency in designing fiber optic probes for biomedical spectroscopy measurement. This model is in general applicable to probes with single or multiple fibers. We investigated a number of probe configurations and find that contact measurement is very inefficient for multi-fiber probes. Contact measurement is a good choice for single-fiber probes, but for multi-fiber probes, there is an optimal probe distance. By carefully choosing the probe and sample distance, the signal can be enhanced by 5-10 fold. Experiments demonstrate the distance dependence of collection efficiency in multi-fiber probes.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Fiber optic probes for biomedical optical spectroscopy
    Utzinger, U
    Richards-Kortum, RR
    JOURNAL OF BIOMEDICAL OPTICS, 2003, 8 (01) : 121 - 147
  • [2] Optical fiber probe for biomedical Raman spectroscopy
    Motz, JT
    Hunter, M
    Galindo, LH
    Gardecki, JA
    Kramer, JR
    Dasari, RR
    Feld, MS
    APPLIED OPTICS, 2004, 43 (03) : 542 - 554
  • [3] Optimization of Fiber radius and Sensor probe-reflector Distance of Trifurcated Fiber Optic Angular Displacement Sensor
    Laddha, R. S.
    Buchade, P. B.
    Shaligram, A. D.
    EMERGING TECHNOLOGIES: MICRO TO NANO (ETMN-2017), 2018, 1989
  • [4] Raman spectroscopy with a fiber-optic probe and multichannel detection
    Vickers, TJ
    Pecha, J
    Mann, CK
    JOURNAL OF CHEMICAL EDUCATION, 2001, 78 (12) : 1674 - 1675
  • [5] Dialysis-assisted fiber optic spectroscopy for in situ biomedical sensing
    Blazkiewicz, P
    Blazkiewicz, K
    Verhaege, A
    Anissimov, YG
    Roberts, MS
    Zvyagin, AV
    JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (01)
  • [6] OPTIMIZATION OF SENSOR PROBE TAPER ANGLE FOR A FIBER OPTIC BIOSENSOR
    ANDERSON, GP
    GOLDEN, JP
    SHRIVERLAKE, LC
    LIGLER, FS
    FASEB JOURNAL, 1992, 6 (01): : A169 - A169
  • [7] Fiber optic probe
    Shah, NA
    PHOTONICS SPECTRA, 1998, 32 (05) : 82 - 82
  • [8] Diffuse reflectance spectroscopy with a self-calibrating fiber optic probe
    Yu, Bing
    Fu, Henry
    Bydlon, Torre
    Bender, Janelle E.
    Ramanujam, Nirmala
    OPTICS LETTERS, 2008, 33 (16) : 1783 - 1785
  • [9] A Self-Calibrating Fiber Optic Probe for Tissue Optical Spectroscopy
    Yu, Bing
    Fu, Henry
    Bydlon, Torre
    Bender, Janelle
    Ramanujam, Nimmi
    2008 CONFERENCE ON LASERS AND ELECTRO-OPTICS & QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE, VOLS 1-9, 2008, : 947 - 948
  • [10] RAMAN-SPECTROSCOPY USING A FIBER OPTIC PROBE WITH SUBWAVELENGTH APERTURE
    TSAI, DP
    OTHONOS, A
    MOSKOVITS, M
    UTTAMCHANDANI, D
    APPLIED PHYSICS LETTERS, 1994, 64 (14) : 1768 - 1770