摘要
Beam size estimates made using beam-beam deflections are used for optimization of the Stanford Linear Collider (SLC) electron-positron beam sizes. Typical beam sizes and intensities expected for 1996 operations are 2.1 x 0.6 mu m (x,y) at 4.0 x 10(10) particles per pulse. Conventional profile monitors, such as scanning wires, fail at charge densities well below this. The laser-based profile monitor uses a finely-focused 350-nm wavelength tripled YLF laser pulse that traverses the particle beam path about 29 cm away from the e(+)/e(-) IF. Compton scattered photons and degraded e(+)/e(-) are detected as the beam is steered across the laser pulse. The laser pulse has a transverse size of 380 nm and a Rayleigh range of about 5 mu m.
引用
收藏
页码:363 / 365
页数:3
相关论文
共 50 条
  • [31] A LASER-BASED HIGHWAY-SPEED ROAD PROFILE MEASURING SYSTEM
    PREM, H
    VEHICLE SYSTEM DYNAMICS, 1988, 17 : 300 - 304
  • [32] The effect of the laser beam intensity profile in laser-based directed energy deposition: A high-fidelity thermal-fluid modeling approach
    Sattari, Mohammad
    Ebrahimi, Amin
    Luckabauer, Martin
    Romex, Gert-Willem R. B. E.
    ADDITIVE MANUFACTURING, 2024, 86
  • [33] Effect of Laser Beam Profile on Thermal Transfer, Fluid Flow and Solidification Parameters during Laser-Based Directed Energy Deposition of Inconel 718
    Chen, Bo
    Bian, Yanhua
    Li, Zhiyong
    Dong, Binxin
    Li, Shaoxia
    Tian, Chongxin
    He, Xiuli
    Yu, Gang
    MATERIALS, 2023, 16 (12)
  • [34] Weak FEL gain detection with a modulated laser-based beam heater
    Emma, P
    Huang, Z
    Wu, J
    2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 2371 - 2373
  • [35] Evaluating specifications of laser beam quality based on beam profile
    Li, Xiaoming
    Shen, Xueju
    Li, Gang
    Liu, Xun
    Zhongguo Jiguang/Chinese Journal of Lasers, 2015, 42 (05):
  • [36] A CVD-diamond based beam profile monitor for undulator radiation
    Schulze-Briese, C
    Ketterer, B
    Pradervand, C
    Brönnimann, C
    David, C
    Horisberger, R
    Puig-Molina, A
    Graafsma, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 230 - 234
  • [37] Suggested parameter to estimate the region probed by photons in laser-based measurements
    Dagdug, L
    Weiss, GH
    JOURNAL OF MODERN OPTICS, 2004, 51 (04) : 469 - 478
  • [38] A BEAM INTENSITY PROFILE MONITOR BASED ON SECONDARY-ELECTRON EMISSION
    BERDOZ, AR
    BIRCHALL, J
    CAMPBELL, JR
    DAVIS, CA
    DAVISON, NE
    GREEN, PW
    KNOLL, M
    KORKMAZ, E
    MISCHKE, RE
    MOSSCROP, DR
    PAGE, SA
    RAMSAY, WD
    ROY, G
    SEKULOVICH, AM
    SOUKUP, J
    STINSON, GM
    STEWART, J
    VANOERS, WTH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 307 (01): : 26 - 34
  • [39] Laser wire beam profile monitor in the spallation neutron source (SNS) superconducting linac
    Liu, Y.
    Aleksandrov, A.
    Assadi, S.
    Blokland, W.
    Deibele, C.
    Grice, W.
    Long, C.
    Pelaia, T.
    Webster, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 612 (02): : 241 - 253
  • [40] A SIMPLE METHOD TO MONITOR THE INTENSITY PROFILE OF A PULSED-LASER BEAM WITH MICROMETER RESOLUTION
    HUTHFEHRE, T
    WESTMAN, A
    SUNDQVIST, BUR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (02): : 511 - 512