Design of a lightweight passive orthosis for tremor suppression

被引:22
|
作者
Fromme, Nicolas Philip [1 ]
Camenzind, Martin [1 ]
Riener, Robert [2 ,3 ]
Rossi, Rene M. [1 ]
机构
[1] Empa, Swiss Fed Labs Mat Sci & Technol, Lab Biomimet Membranes & Text, Lerchenfeldstr 5, CH-9014 St Gallen, Switzerland
[2] Swiss Fed Inst Technol, Sensory Motor Syst Lab, Dept Hlth Sci & Technol, Inst Robot & Intelligent Syst, Tannenstr 1,TAN E 5, CH-8092 Zurich, Switzerland
[3] Univ Zurich, Spinal Cord Injury Ctr, Univ Hosptial Balgrist, Fac Med, Lengghalde 5, CH-8008 Zurich, Switzerland
关键词
Tremor; Suppression; Wearable; Upper limb; Orthosis; Comfort; Textile integrated; Laser welding; Soft; Variable stiffness; PARKINSONS-DISEASE; CONSENSUS STATEMENT; TASK-FORCE; PREVALENCE; COMFORT; PERFORMANCE; WRIST;
D O I
10.1186/s12984-020-00673-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background Tremor is the most common movement disorder with the highest prevalence in the upper limbs. The mechanical suppression of involuntary movements is an alternative and additional treatment to medication or surgery. Here we present a new, soft, lightweight, task asjustable and passive orthosis for tremor suppression. Methods A new concept of a manual, textile-based, passive orthosis was designed with an integrated, task adjustable, air-filled structure, which can easily be inflated or deflated on-demand for a certain daily activity. The air-filled structure is placed on the dorsal side of the wrist and gets bent and compressed by movements when inflated. In a constant volume air-filled structure, air pressure increases while it is inflating, creating a counterforce to the compression caused by bending. We characterised the air-filled structure stiffness by measuring the reaction torque as a function of the angle of deflection on a test bench. Furthermore, we evaluated the efficacy of the developed passive soft orthosis by analysing the suppression of involuntary movements in the wrist of a tremor-affected patient during different activities of daily living (i.e. by calculating the power spectral densities of acceleration). Results By putting special emphasis on the comfort and wearability of the orthosis, we achieved a lightweight design (33 g). The measurements of the angular deflection and resulting reaction torques show non-linear, hysteretic, behaviour, as well as linear behaviour with a coefficient of determination (R-2) between 0.95 and 0.99. Furthermore, we demonstrated that the soft orthosis significantly reduces tremor power for daily living activities, such as drinking from a cup, pouring water and drawing a spiral, by 74 to 82% (p = 0.03); confirmed by subjective tremor-reducing perception by the patient. Conclusion The orthosis we developed is a lightweight and unobtrusive assistive technology, which suppresses involuntary movements and shows high wearability properties, with the potential to be comfortable. This air-structure technology could also be applied to other movement disorders, like spasticity, or even be integrated into future exoskeletons and exosuits for the implementation of variable stiffness in the systems.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Design and Fabrication of a Passive Pelvic Orthosis for Treadmill Walking Rehabilitation
    Ali Mokhtarian
    Abbas Fattah
    Mehdi Keshmiri
    Journal of Bionic Engineering, 2023, 20 : 1036 - 1048
  • [22] Parametric Design of an Active Ankle Foot Orthosis with Passive Compliance
    Carberry, James
    Hinchly, Graham
    Buckerfield, James
    Tayler, Edward
    Burton, Thomas
    Madgwick, Sebastian
    Vaidyanathan, Ravi
    2011 24TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS), 2011,
  • [23] Mechanical Design of a Lightweight Compliant and Adaptable Active Ankle Foot Orthosis
    Moltedo, Marta
    Bacek, Tomislav
    Junius, Karen
    Vanderborght, Bram
    Lefeber, Dirk
    2016 6TH IEEE INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2016, : 1224 - 1229
  • [24] Tremor suppression strategy of the tremor suppression robot
    赵杰
    李军强
    樊继壮
    臧希喆
    Journal of Harbin Institute of Technology(New series), 2012, (01) : 1 - 6
  • [25] Tremor suppression strategy of the tremor suppression robot
    赵杰
    李军强
    樊继壮
    臧希喆
    Journal of Harbin Institute of Technology, 2012, 19 (01) : 1 - 6
  • [26] Upper limb tremor suppression in ADL via an orthosis incorporating a controllable double viscous beam actuator
    Loureiro, RCV
    Belda-Lois, JM
    Lima, ER
    Pons, JL
    Sanchez-Lacuesta, JJ
    Harwin, WS
    2005 IEEE 9TH INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS, 2005, : 119 - 122
  • [27] Design and Evaluation of a Hybrid Passive and Active Gravity Neutral Orthosis (GNO)
    Koo, Benjamin
    Montes, Jacqueline
    Gamarnik, Viktor
    Yeager, Keith
    Marra, Jonathan
    Dunaway, Sally
    Montgomery, Megan
    De Vivo, Darryl C.
    Strauss, Nancy
    Konofagou, Elisa
    Kaufmann, Petra
    Morrison, Barclay
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 1573 - +
  • [28] Design of Parallel Exoskeleton System for Wrist Tremor Suppression
    Janakaraj, Sudarsana Jayandan
    Barry, Oumar
    IFAC PAPERSONLINE, 2023, 56 (03): : 289 - 294
  • [29] Design and validation of a rehabilitation robotic exoskeleton for tremor assessment and suppression
    Rocon, E.
    Belda-Lois, J. M.
    Ruiz, A. F.
    Manto, M.
    Moreno, J. C.
    Pons, J. L.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2007, 15 (03) : 367 - 378
  • [30] Design and Preliminary Performance Assessment of a Wearable Tremor Suppression Glove
    Zhou, Yue
    Ibrahim, Anas
    Hardy, Kenneth G.
    Jenkins, Mary E.
    Naish, Michael D.
    Trejos, Ana Luisa
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (09) : 2846 - 2857