Robustness comparative study of dose-volume-histogram prediction models for knowledge-based radiotherapy treatment planning

被引:2
|
作者
Wu, Aiqian [1 ]
Li, Yongbao [2 ]
Qi, Mengke [1 ]
Jia, Qiyuan [1 ]
Guo, Futong [1 ]
Lu, Xingyu [1 ]
Zhou, Linghong [1 ]
Song, Ting [1 ]
机构
[1] Southern Med Univ, Dept Biomed Engn, Guangzhou, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, State Key Lab Oncol South China, Collaborat Innovat Ctr Canc Med, Dept Radiat Oncol,Canc Ctr, Guangzhou, Guangdong, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Robustness comparison; DVH prediction model; knowledge-based radiotherapy; MODULATED RADIATION-THERAPY; IMRT; HEAD; NECK;
D O I
10.1080/16878507.2020.1745387
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: To compare the robustness of three dose-volume-histogram (DVH) prediction models for knowledge-based treatment planning (KBP) for radiation therapy. Methods: Three models proposed by Zhu et al. (Zmodel), Lindsey et al. (Lmodel), and Satomi et al. (Smodel) were selected, and compared based on identified archived radiation therapy plan cohorts (including 50 prostate cancer (PC) and 29 nasopharynx cancer (NPC) cases). Robustness comparison was performed by observing changes in prediction accuracy in relation to training example size, and further analyzing the number of training samples required for each model. In addition, a robustness comparison of models on different case applications was conducted to verify the applicability of models on different tumor sites. The error of model predictions was measured by the difference between predicted and clinical DVH. Results: The minimum necessary datasets required to train the model are 35, 40, and 45 for Lmodel, Zmodel, and Smodel, respectively. Smodel has high accuracy on both PC and NPC databases, achieving a median prediction error of 0.0257 on the training dataset and 0.0446 on the evaluation dataset. In a specific case, Smodel and Zmodel exhibit the best result on PC (with prediction errors of 0.0464) and NPC case applications (with prediction errors of 0.0228), respectively. Conclusions: Lmodel needs the least number of samples necessary for training. Smodel and Zmodel are optimal for the PC and NPC cases, respectively. In different case applications, Smodel performs more stable. Planners or researchers should carefully select an appropriate method under specific requirements.
引用
收藏
页码:390 / 397
页数:8
相关论文
共 50 条
  • [41] Knowledge-based inverse treatment planning for low-dose-rate prostate brachytherapy
    Guthier, Christian V.
    Orio, Peter F., III
    Buzurovic, Ivan
    Cormack, Robert A.
    MEDICAL PHYSICS, 2021, 48 (05) : 2108 - 2117
  • [42] A two-step treatment planning strategy incorporating knowledge-based planning for head-and-neck radiotherapy
    Liu, Han
    Sintay, Benjamin
    Wiant, David
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (06):
  • [43] Knowledge-Based Automatic Treatment Planning for Prostate IMRT Using 3-Dimensional Dose Prediction and Threshold-Based Optimization
    Folkerts, M.
    Long, T.
    Radke, R.
    Lu, W.
    Jia, X.
    Gu, X.
    Chen, M.
    Jiang, S.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [44] A geometry and dose-volume based performance monitoring of artificial intelligence models in radiotherapy treatment planning for prostate cancer
    De Kerf, Geert
    Claessens, Michael
    Raouassi, Fadoua
    Mercier, Carole
    Stas, Daan
    Ost, Piet
    Dirix, Piet
    Verellen, Dirk
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 28
  • [45] A Knowledge-Based Organ Dose Prediction Tool for Brachytherapy Treatment of Cervical Cancer Patients
    Yusufaly, T. I.
    Simon, A.
    Hild, S.
    Brown, D.
    Scanderbeg, D.
    Mayadev, J.
    Moore, K. L.
    Meyers, S. M.
    MEDICAL PHYSICS, 2019, 46 (06) : E248 - E249
  • [46] Pilot study in the treatment of endometrial carcinoma with 3D image based high-dose-rate brachytherapy using modified Heyman packing:: Clinical experience and dose-volume-histogram analysis
    Weitmann, H. D.
    Poetter, R.
    Waldhaeusl, C.
    Nechvile, E.
    Kirisits, Ch.
    Knocke, T. H.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 197 - 197
  • [47] A dose-volume histogram based decision-support system for dosimetric comparison of radiotherapy treatment plans
    J. C. L. Alfonso
    M. A. Herrero
    L. Núñez
    Radiation Oncology, 10
  • [48] A dose-volume histogram based decision-support system for dosimetric comparison of radiotherapy treatment plans
    Alfonso, J. C. L.
    Herrero, M. A.
    Nunez, L.
    RADIATION ONCOLOGY, 2015, 10
  • [49] A deep learning-based dose prediction method for evaluation of radiotherapy treatment planning
    Liu, Jiping
    Zhang, Xiang
    Cheng, Xiaolong
    Sun, Long
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2024, 17 (01)
  • [50] Enhancing Hypo-Fractionated Prostate Cancer Radiotherapy in Nigeria: A Knowledge-Based Treatment Planning Approach
    Adeneye, S. O.
    Joseph, A.
    Miracle, M. C.
    Ibitoye, A.
    Lehmann, J.
    Avery, S. M.
    Mkhize, T.
    Kisukari, J. Dachi
    Mallum, A.
    Alabi, A.
    Oderinde, O.
    Taiwo, M. D.
    Dinyo, A.
    Olatunji, E.
    Graef, K.
    Wijesooriya, K.
    Huq, M. S.
    Swanson, W. J.
    Li, H.
    Patel, S.
    Ajose, A.
    Ngoma, T.
    Ngwa, W. F.
    Weygand, J.
    MEDICAL PHYSICS, 2024, 51 (10) : 7815 - 7816