Investigating the Dialysis Treatment Using Hollow Fiber Membrane: A New Approach by CFD

被引:3
|
作者
Magalhaes, Hortencia L. F. [1 ]
Gomez, Ricardo S. [2 ]
Leite, Boniek E. [3 ]
Nascimento, Jessica B. S. [3 ,4 ]
Brito, Mirenia K. T. [3 ]
Araujo, Morgana, V [3 ]
Cavalcante, Daniel C. M. [5 ]
Lima, Elisiane S. [3 ]
Lima, Antonio G. B. [2 ,3 ]
Neto, Severino R. Farias [1 ,3 ]
机构
[1] Univ Fed Campina Grande, Dept Chem Engn, BR-58429900 Campina Grande, Paraiba, Brazil
[2] Univ Fed Campina Grande, Dept Mech Engn, BR-58429900 Campina Grande, Paraiba, Brazil
[3] Univ Fed Campina Grande, Dept Proc Engn, BR-58429900 Campina Grande, Paraiba, Brazil
[4] Univ Estadual Santa Cruz, Dept Exact Sci & Technol, BR-46662900 Ilheus, BA, Brazil
[5] Fed Inst Educ Sci & Technol Sertao Pernambucano, BR-56915899 Serra Talhada, Brazil
关键词
computational fluid dynamics; hemodialysis; membrane; MASS-TRANSFER; SOLUTE REMOVAL; TRANSPORT; SIMULATION;
D O I
10.3390/membranes12070710
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Due to the increase in the number of people affected by chronic renal failure, the demand for hemodialysis treatment has increased considerably over the years. In this sense, theoretical and experimental studies to improve the equipment (hemodialyzer) are extremely important, due to their potential impact on the patient's life quality undergoing treatment. To contribute to this research line, this work aims to study the fluid behavior inside a hollow fiber dialyzer using computational fluid dynamics. In that new approach, the blood is considered as multiphase fluid and the membrane as an extra flow resistance in the porous region (momentum sink). The numerical study of the hemodialysis process was based on the development of a mathematical model that allowed analyzing the performance of the system using Ansys (R) Fluent software. The predicted results were compared with results reported in the literature and a good concordance was obtained. The simulation results showed that the proposed model can predict the fluid behavior inside the hollow fiber membrane adequately. In addition, it was found that the clearance decreases with increasing radial viscous resistance, with greater permeations in the vicinity of the lumen inlet region, as well as the emergence of the retrofiltration phenomenon, characteristic of this type of process. Herein, velocity, pressure, and volumetric fraction fields are presented and analyzed.
引用
收藏
页数:23
相关论文
共 50 条
  • [31] Effect of the inlet manifold on the performance of a hollow fiber membrane module-A CFD study
    Zhuang, Liwei
    Guo, Hanfei
    Dai, Gance
    Xu, Zhen-liang
    JOURNAL OF MEMBRANE SCIENCE, 2017, 526 : 73 - 93
  • [32] Direct Membrane Filtration for Wastewater Treatment Using an Intermittent Rotating Hollow Fiber Module
    Ruigomez, Ignacio
    Gonzalez, Enrique
    Rodriguez-Gomez, Luis
    Vera, Luisa
    WATER, 2020, 12 (06)
  • [33] Treatment of Waste Carwash Water by Flocculation and Filtration Using Submerged Hollow Fiber Membrane
    Hamada, Toyozo
    Waki, Toshinori
    Watabe, Tomoichi
    Nakatsuka, Shuji
    KAGAKU KOGAKU RONBUNSHU, 2009, 35 (01) : 111 - 116
  • [34] Spiral wound, hollow fiber membrane modules: A new approach to higher mass transfer efficiency
    Crowder, ML
    Gooding, CH
    JOURNAL OF MEMBRANE SCIENCE, 1997, 137 (1-2) : 17 - 29
  • [35] Purification of Palm Oil by Using Hollow Fiber Membrane
    Arahman, Nasrul
    Erika, Cut
    Putra, Alfian
    AGRITECH, 2013, 33 (01): : 32 - 37
  • [36] Odor control using hollow fiber membrane modules
    Tan, XY
    Li, K
    Teo, WK
    AICHE JOURNAL, 2005, 51 (05) : 1367 - 1376
  • [37] METAL COLLECTION USING CHELATING HOLLOW FIBER MEMBRANE
    TSUNEDA, S
    SAITO, K
    FURUSAKI, S
    SUGO, T
    OKAMOTO, J
    JOURNAL OF MEMBRANE SCIENCE, 1991, 58 (02) : 221 - 234
  • [38] PLASMA SEPARATION USING A HOLLOW FIBER MEMBRANE DEVICE
    BUCHHOLZ, DH
    LIN, A
    SNYDER, E
    MCCULLOUGH, J
    PORTEN, J
    ANDERSON, M
    SMITH, J
    DALMASSO, A
    HELPHINGSTINE, C
    PATH, M
    TRANSFUSION, 1986, 26 (02) : 145 - 150
  • [39] CFD simulation of acetone separation from an aqueous solution using supercritical fluid in a hollow-fiber membrane contactor
    Miramini, Seyed Abolfazl
    Razavi, S. M. R.
    Ghadiri, Mehdi
    Mandavi, S. Z.
    Moradi, Sadegh
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2013, 72 : 130 - 136
  • [40] Biogas Conditioning Using Hollow Fiber Membrane Contactors
    Vogler, Steffen
    Braasch, Axel
    Buse, Gerhard
    Hempel, Soeren
    Schneider, Juergen
    Ulbricht, Martin
    CHEMIE INGENIEUR TECHNIK, 2013, 85 (08) : 1254 - 1258