Aliquoting on the centrifugal microfluidic platform based on centrifugo-pneumatic valves

被引:79
|
作者
Mark, Daniel [1 ]
Weber, Patrick [2 ]
Lutz, Sascha [1 ]
Focke, Maximilian [2 ]
Zengerle, Roland [1 ,2 ,3 ]
von Stetten, Felix [1 ,2 ]
机构
[1] HSG IMIT, D-78052 Villingen Schwenningen, Germany
[2] Univ Freiburg, Dept Microsyst Engn IMTEK, Lab MEMS Applicat, D-79110 Freiburg, Germany
[3] Univ Freiburg, Ctr Biol Signalling Studies BIOSS, D-79110 Freiburg, Germany
关键词
Lab-on-a-chip; Centrifugal microfluidics; Aliquoting; Multiplexing; PCR; Pneumatic; POLYMERASE-CHAIN-REACTION; WHOLE-BLOOD ANALYZER; LAB;
D O I
10.1007/s10404-010-0759-0
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We present a new method for aliquoting liquids on the centrifugal microfluidic platform. Aliquoting is an essential unit operation to perform multiple parallel assays ("geometric multiplexing") from one individual sample, such as genotyping by real-time polymerase chain reactions (PCR), or homogeneous immunoassay panels. Our method is a two-stage process with an initial metering phase and a subsequent transport phase initiated by switching a centrifugo-pneumatic valve. The method enables aliquoting liquids into completely separated reaction cavities. It includes precise metering that is independent on the volume of pre-stored reagents in the receiving cavities. It further excludes any cross-contamination between the receiving cavities. We characterized the performance for prototypes fabricated by three different technologies: micro-milling, thermoforming of foils, and injection molding. An initial volume of similar to 90 mu l was split into 8 aliquots of 10 mu l volume each plus a waste reservoir on a thermoformed foil disk resulting in a coefficient of variation (CV) of the metered volumes of 3.6%. A similar volume of similar to 105 mu l was split into 16 aliquots of 6 mu l volume each on micro-milled and injection-molded disks and the corresponding CVs were 2.8 and 2.2%, respectively. Thus, the compatibility of the novel aliquoting structure to the aforementioned prototyping and production technologies is demonstrated. Additionally, the important question of achievable volume precision of the aliquoting structure with respect to the production tolerances inherent to each of these production technologies is addressed experimentally and theoretically. The new method is amenable to low cost mass production, since it does not require any post-replication surface modifications like hydrophobic patches.
引用
收藏
页码:1279 / 1288
页数:10
相关论文
共 50 条
  • [1] Aliquoting on the centrifugal microfluidic platform based on centrifugo-pneumatic valves
    Daniel Mark
    Patrick Weber
    Sascha Lutz
    Maximilian Focke
    Roland Zengerle
    Felix von Stetten
    Microfluidics and Nanofluidics, 2011, 10 : 1279 - 1288
  • [2] Centrifugo-pneumatic multi-liquid aliquoting-parallel aliquoting and combination of multiple liquids in centrifugal microfluidics
    Schwemmer, F.
    Hutzenlaub, T.
    Buselmeier, D.
    Paust, N.
    von Stetten, F.
    Mark, D.
    Zengerle, R.
    Kosse, D.
    LAB ON A CHIP, 2015, 15 (15) : 3250 - 3258
  • [3] Centrifugo-pneumatic valve for metering of highly wetting liquids on centrifugal microfluidic platforms
    Mark, Daniel
    Metz, Tobias
    Haeberle, Stefan
    Lutz, Sascha
    Ducree, Jens
    Zengerle, Roland
    von Stetten, Felix
    LAB ON A CHIP, 2009, 9 (24) : 3599 - 3603
  • [4] Centrifugo-pneumatic valving utilizing dissolvable films
    Gorkin, Robert, III
    Nwankire, Charles E.
    Gaughran, Jennifer
    Zhang, Xin
    Donohoe, Gerard G.
    Rook, Martha
    O'Kennedy, Richard
    Ducree, Jens
    LAB ON A CHIP, 2012, 12 (16) : 2894 - 2902
  • [5] Centrifugo-pneumatic sedimentation, re-suspension and transport of microparticles
    Zhao, Y.
    Schwemmer, F.
    Zehnle, S.
    von Stetten, F.
    Zengerle, R.
    Paust, N.
    LAB ON A CHIP, 2015, 15 (21) : 4133 - 4137
  • [6] Density-Gradient Mediated Band Extraction of Leukocytes from Whole Blood Using Centrifugo-Pneumatic Siphon Valving on Centrifugal Microfluidic Discs
    Kinahan, David J.
    Kearney, Sinead M.
    Kilcawley, Niamh A.
    Early, Philip L.
    Glynn, Macdara T.
    Ducree, Jens
    PLOS ONE, 2016, 11 (05):
  • [7] Network simulation-based optimization of centrifugo-pneumatic blood plasma separation
    Zehnle, S.
    Rombach, M.
    Zengerle, R.
    von Stetten, F.
    Paust, N.
    BIOMICROFLUIDICS, 2017, 11 (02):
  • [8] Centrifugo-dynamic inward pumping of liquids on a centrifugal microfluidic platform
    Zehnle, Steffen
    Schwemmer, Frank
    Roth, Guenter
    von Stetten, Felix
    Zengerle, Roland
    Paust, Nils
    LAB ON A CHIP, 2012, 12 (24) : 5142 - 5145
  • [9] GRAPHENE-OXIDE ENABLED CENTRIFUGO-PNEUMATIC ROUTING OF FLOWS
    Gaughran, Jennifer
    Ducree, Jens
    2015 TRANSDUCERS - 2015 18TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2015, : 331 - 334
  • [10] Secure Air Traffic Control at the Hub of Multiplexing on the Centrifugo-Pneumatic Lab-on-a-Disc Platform
    Ducree, Jens
    MICROMACHINES, 2021, 12 (06)