Improvement of precision in quantitative measurements of radioactivity with an imaging plate

被引:5
|
作者
Suzuki, T
Mori, C
Miyahara, H
Uritani, A
Yoshida, M
Takahashi, F
机构
[1] Nagoya Univ, Dept Nucl Engn, Chikusa Ku, Nagoya, Aichi 46401, Japan
[2] Japan Atom Energy Res Inst, Tokai Estab, Dept Hlth Phys, Tokai, Ibaraki 31911, Japan
关键词
D O I
10.1016/S0969-8043(97)10032-X
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
To obtain a high precision in radiation or radioactivity measurements with an imaging plate, the photo-stimulated luminescence intensity must be large. To get the highest intensity, we reread an imaging plate repeatedly and summed each intensity for the purpose of reducing the variation of the measured intensities. A great improvement of the precision in the measurement was achieved with the method of repeated readings when the time interval between each reading is more than about 1 h. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1127 / 1130
页数:4
相关论文
共 50 条
  • [21] Quantitative imaging of assays in miniaturized plate formats
    Sun, G
    Ramm, P
    [J]. SYSTEMS AND TECHNOLOGIES FOR CLINICAL DIAGNOSTICS AND DRUG DISCOVERY, PROCEEDINGS OF, 1998, 3259 : 219 - 227
  • [22] EVALUATION OF PRECISION OF QUANTITATIVE MOLECULAR ABSORPTION SPECTROMETRIC MEASUREMENTS
    INGLE, JD
    CROUCH, SR
    [J]. ANALYTICAL CHEMISTRY, 1972, 44 (08) : 1375 - &
  • [23] Quantitative ultrasound measurements: Short and long term precision
    Ingle, BM
    Eastell, R
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1996, 11 (11) : P59 - P59
  • [24] Increasing the Precision of Quantitative CBED Structure Factor Measurements
    Nakashima, Philip
    [J]. ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2005, 61 : C457 - C457
  • [25] Validation of Quantitative Measurements in Cardiovascular Imaging
    van Ooijen, Peter M. A.
    Francone, Marco
    Lotz, Joachim
    Rasche, Volker
    [J]. BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [26] Beam profile measurements with a phosphor imaging plate
    Weissman, L
    Hass, M
    Popov, V
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 400 (2-3): : 409 - 413
  • [27] An alternative method for radioactivity measurement in quantitative bone SPECT/CT imaging
    Ishihara, Masaru
    Kato, Yasuaki
    Onoguchi, Masahisa
    Shibutani, Takayuki
    [J]. SCIENCE PROGRESS, 2021, 104 (03)
  • [28] Effect of background radiation shielding on natural radioactivity distribution measurement with imaging plate
    Mori, C
    Suzuki, T
    Koido, S
    Uritani, A
    Miyahara, H
    Yanagida, K
    Miyahara, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 369 (2-3): : 544 - 546
  • [29] The precision improvement of the scanner in optical scanning imaging system
    Xiang, JY
    Wu, Z
    Zhang, P
    Huang, DX
    Wei, GS
    [J]. OPTICS AND LASER TECHNOLOGY, 1998, 30 (02): : 109 - 112
  • [30] Towards precision medicine: from quantitative imaging to radiomics
    Acharya, U. Rajendra
    Hagiwara, Yuki
    Sudarshan, Vidya K.
    Chan, Wai Yee
    Ng, Kwan Hoong
    [J]. JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B, 2018, 19 (01): : 6 - 24