Supraspinatus tendon measurement using high frequency ultrasound in Sudanese pediatrics

被引:1
|
作者
Elgyoum, Ala M. A. [1 ]
Mohammed, Marwa H. [2 ]
Abdelrahim, Ahmed [2 ]
Zidan, Mogahid M. A. [1 ]
Alsaadi, Mohammed [3 ]
Salih, Mohammed [4 ]
Elhaj, Mona [5 ]
Davidson, Rob [6 ]
Mahmoud, Mustafa Z. [3 ,6 ]
机构
[1] Natl Ribat Univ, Fac Radiol & Nucl Med Sci, Khartoum, Sudan
[2] Alzaiem Alazhari Univ, Fac Radiol Sci & Med Imaging, Khartoum, Sudan
[3] Prince Sattam Bin Abdulaziz Univ, Coll Appl Med Sci, Radiol & Med Imaging Dept, Al Kharj, Saudi Arabia
[4] Univ Hail, Coll Appl Med Sci, Diagnost Radiol Dept, Haiil, Saudi Arabia
[5] Taif Univ, Coll Appl Med Sci, Dept Radiol Sci, At Taif, Saudi Arabia
[6] Univ Canberra, Fac Hlth, Canberra, ACT, Australia
关键词
Pediatrics; musculoskeletal; supraspinatus tendon; ultrasound; ROTATOR CUFF; ANATOMY; DIMENSIONS; THICKNESS; ANTERIOR;
D O I
10.1080/16878507.2021.1999718
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The frequency of rotator cuff diseases makes shoulder ultrasound (US) one of the most prevalent musculoskeletal ultrasound (MSK US) applications. Sudanese children's supraspinatus tendon thickness and width were measured as part of this study to help with the early detection of supraspinatus tendon disease. Between August and December 2020, researchers conducted this cross-sectional investigation. There were 114 participants in the study, ranging in age from 4 to 14 years, with 81 males (71.1%) and 33 females (28.9%) participating. Study variables were incorporated into a customized data collection sheet used to gather the information. The supraspinatus tendons were found to be 5.31 +/- 0.69 mm in thickness and 26.91 +/- 2.06 mm in width. While the supraspinatus tendon thickness was correlated significantly (p < 0.01) to age (r = 0.280), weight (r = 0.254), and height (r = 0.335) in terms of their p-values, it was not correlated significantly to body mass index (BMI) (p > 0.05). A significant correlation (p < 0.01) was found between the supraspinatus tendon's width and age (r = 0.519), weight (r = 0.507), height (r = 0.489), and BMI (r = 0.309). Standard reference values for supraspinatus tendon measures were found in Sudanese children. US musculoskeletal assessments of the supraspinatus tendons are proposed as a method for detecting anomalies in these tendons.
引用
收藏
页码:502 / 506
页数:5
相关论文
共 50 条
  • [31] Characterization of the extensor digitorum communis tendon using high-frequency ultrasound shear wave elastography
    Hsiao, Yan-Yi
    Yang, Tai-Hua
    Chen, Pei-Yu
    Hsu, Hsiu-Yun
    Kuo, Li-Chieh
    Su, Fong-Chin
    Huang, Chih-Chung
    MEDICAL PHYSICS, 2020, 47 (04) : 1609 - 1618
  • [32] ANALYSIS OF COLLAGEN FIBER ORGANIZATION IN MOUSE ACHILLES TENDON USING HIGH-FREQUENCY ULTRASOUND IMAGING
    Riggin, Corinne N.
    Sarver, Joseph J.
    Freedman, Benjamin R.
    Thomas, Stephen J.
    Soslowsky, Louis J.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT B, 2014,
  • [33] Supraspinatus tendon repair using anchors: a biomechanical evaluation in the rabbit
    Louati, Hakim
    Uhthoff, Hans K.
    Culliton, Kathryn
    Laneuville, Odette
    Lapner, Peter
    Trudel, Guy
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [34] Ultrasonographic Measurement of the Achilles and Supraspinatus Tendon Thicknesses in Patients with Chronic Lead Exposure
    Baki, A. E.
    Yildizgoren, M. T.
    Kara, M.
    Ekiz, T.
    Tutkun, E.
    Ozcakar, L.
    WEST INDIAN MEDICAL JOURNAL, 2015, 64 (04): : 384 - 387
  • [35] Supraspinatus tendon repair using anchors: a biomechanical evaluation in the rabbit
    Hakim Louati
    Hans K. Uhthoff
    Kathryn Culliton
    Odette Laneuville
    Peter Lapner
    Guy Trudel
    Journal of Orthopaedic Surgery and Research, 13
  • [36] Ultrasound changes after rotator cuff repair: is supraspinatus tendon thickness related to pain?
    Tham, Elizabeth R. X.
    Briggs, Lisa
    Murrell, George A. C.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (08) : E8 - E15
  • [37] Inter-rater reliability in the classification of supraspinatus tendon tears using 3D ultrasound - a question of experience?
    Tamborrini, Giorgio
    Marx, Christian
    Micheroli, Raphael
    JOURNAL OF ULTRASONOGRAPHY, 2016, 16 (66) : 252 - 259
  • [38] Ultrasound Measures of Supraspinatus Tendon Thickness and Acromiohumeral Distance in Rotator Cuff Tendinopathy Are Reliable
    McCreesh, Karen M.
    Anjum, Shakeel
    Crotty, James M.
    Lewis, Jeremy S.
    JOURNAL OF CLINICAL ULTRASOUND, 2016, 44 (03) : 159 - 166
  • [39] QUANTITATIVE MEASUREMENT OF RESIDUAL POROSITY OF SURGICAL CEMENTS USING HIGH-FREQUENCY ULTRASOUND
    PERNOD, P
    DELEBARRE, C
    HERNIGOU, P
    FRANCES, H
    JOURNAL DE PHYSIQUE IV, 1994, 4 (C5): : 1239 - 1242
  • [40] Quantitative Ultrasound Facilitates the Exploration of Morphological Association of the Long Head Biceps Tendon with Supraspinatus Tendon Full Thickness Tear
    Chang, Ke-Vin
    Chen, Wen-Shiang
    Wang, Tyng-Guey
    Hung, Chen-Yu
    Chien, Kuo-Liong
    PLOS ONE, 2014, 9 (11):