Measuring Saccade Latency Using Smartphone Cameras

被引:19
|
作者
Lai, Hsin-Yu [1 ]
Saavedra-Pena, Gladynel [1 ]
Sodini, Charles G. [2 ,3 ]
Sze, Vivienne [1 ,4 ]
Heldt, Thomas [2 ,4 ]
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[2] MIT, Dept Elect Engn & Comp Sci, Inst Med Engn & Sci, Cambridge, MA 02139 USA
[3] MIT, Microsyst Technol Lab, Cambridge, MA 02139 USA
[4] MIT, Res Lab Elect, Cambridge, MA 02139 USA
关键词
Diseases; Cameras; Task analysis; Visualization; Portable computers; Biomedical measurement; Face; Eye tracking; convolutional neural networks; health monitoring; saccade latency; mobile imaging; FRONTOTEMPORAL LOBAR DEGENERATION; MENTAL-STATE-EXAMINATION; TEST-RETEST RELIABILITY; EYE-MOVEMENTS; COGNITIVE IMPAIRMENT; OCULOMOTOR FUNCTION; PARKINSONS-DISEASE; RESPONSE-TIMES; DEMENTIA; VARIABILITY;
D O I
10.1109/JBHI.2019.2913846
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Objective: Accurate quantification of neurodegenerative disease progression is an ongoing challenge that complicates efforts to understand and treat these conditions. Clinical studies have shown that eye movement features may serve as objective biomarkers to support diagnosis and tracking of disease progression. Here, we demonstrate that saccade latency-an eye movement measure of reaction time-can be measured robustly outside of the clinical environment with a smartphone camera. Methods: To enable tracking of saccade latency in large cohorts of patients and control subjects, we combined a deep convolutional neural network for gaze estimation with a model-based approach for saccade onset determination that provides automated signal-quality quantification and artifact rejection. Results: Simultaneous recordings with a smartphone and a high-speed camera resulted in negligible differences in saccade latency distributions. Furthermore, we demonstrated that the constraint of chinrest support can be removed when recording healthy subjects. Repeat smartphone-based measurements of saccade latency in 11 self-reported healthy subjects resulted in an intraclass correlation coefficient of 0.76, showing our approach has good to excellent test-retest reliability. Additionally, we conducted more than 19 000 saccade latency measurements in 29 self-reported healthy subjects and observed significant intra- and inter-subject variability, which highlights the importance of individualized tracking. Lastly, we showed that with around 65 measurements we can estimate mean saccade latency to within less-than-10-ms precision, which takes within 4 min with our setup. Conclusion and Significance: By enabling repeat measurements of saccade latency and its distribution in individual subjects, our framework opens the possibility of quantifying patient state on a finer timescale in a broader population than previously possible.
引用
收藏
页码:885 / 897
页数:13
相关论文
共 50 条
  • [21] LATER predicts saccade latency distributions in reading
    Carpenter, R. H. . S.
    McDonald, Scott A.
    EXPERIMENTAL BRAIN RESEARCH, 2007, 177 (02) : 176 - 183
  • [22] Revisiting Autofocus for Smartphone Cameras
    Abuolaim, Abdullah
    Punnappurath, Abhijith
    Brown, Michael S.
    COMPUTER VISION - ECCV 2018, PT 15, 2018, 11219 : 545 - 559
  • [23] The influence of the number of decision branches on saccade latency
    Yokoi, Hiroyuki
    Ishii, Masahiro
    I-PERCEPTION, 2011, 2 (04): : 336 - 336
  • [24] The spatial impact of visual distractors on saccade latency
    McSorley, Eugene
    McCloy, Rachel
    Lyne, Clare
    VISION RESEARCH, 2012, 60 : 61 - 72
  • [25] Saccade Latency and Fixation Stability: Repeatability and Reliability
    Vikesdal, Gro Horgen
    Langaas, Trine
    JOURNAL OF EYE MOVEMENT RESEARCH, 2016, 9 (02):
  • [26] Measuring 2D:4D finger length ratios with Smartphone Cameras
    Sandnes, Frode Eika
    2014 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN AND CYBERNETICS (SMC), 2014, : 1697 - 1701
  • [27] Using smartphone thermal cameras to engage students' misconceptions about energy
    Kubsch, Marcus
    Nordine, Jeffrey
    Hadinek, David
    PHYSICS TEACHER, 2017, 55 (08): : 504 - 505
  • [28] Dynamic Offset Correction for Smartphone Thermal Cameras Using a Wristband Sensor
    Yoshikawa, Hiroki
    Uchiyama, Akira
    Higashino, Teruo
    2019 IEEE INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING AND COMMUNICATIONS WORKSHOPS (PERCOM WORKSHOPS), 2019, : 165 - 170
  • [29] Towards Reduced Latency in Saccade Landing Position Prediction Using Velocity Profile Methods
    Griffith, Henry
    Biswas, Subir
    Komogortsev, Oleg
    PROCEEDINGS OF THE FUTURE TECHNOLOGIES CONFERENCE (FTC) 2018, VOL 1, 2019, 880 : 79 - 91
  • [30] Measuring magnification of virtual images using digital cameras
    Kutzner, Mickey D.
    Snelling, Samantha
    PHYSICS TEACHER, 2016, 54 (08): : 503 - 503