An off-line gating method for suppressing motion artifacts in ICUS sequence

被引:11
|
作者
Sun Zheng [1 ]
Yan Qi [2 ]
机构
[1] N China Elect Power Univ, Dept Elect & Commun Engn, Baoding 071003, Peoples R China
[2] Hebei Univ, Affiliated Hosp, Dept Internal Med, Baoding 071003, Peoples R China
关键词
Coronary artery; Intracoronary ultrasound (ICUS); Motion artifact; Gating; Image property; INTRACORONARY ULTRASOUND IMAGES;
D O I
10.1016/j.compbiomed.2010.09.006
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Intracoronary ultrasound (ICUS) imaging, an invasive catheter-based imaging modality, has been widely used in clinical diagnosis of coronary artery diseases. Motion artifacts due to cyclic cardiac motion and pulsatile blood are the main factors that hinder the visualization of ICUS longitudinal cut and 3D vessel reconstruction from ICUS image sequence. The aim of this work is to propose an off-line gating method based on ICUS image properties to suppress motion artifacts for continuous pullback ICUS image sequences acquired in vivo covering several cardiac cycles without the help of ECG signals. Based on analysis of intensity features of each ICUS frame, a difference matrix is firstly constructed. Then, potential information about cardiac cycle is extracted from the matrix and the correspondence of each ICUS frame in successive cardiac cycles is obtained through finding a globally optimal path with the lowest cumulative difference value in the matrix. Finally, a subsequence of frames each acquired at the end-diastole of each cardiac cycle is selected to obtain the gated sequence. The main advantage of this method is that it is applicable to those ICUS sequences where the subject's heart rate may be irregular during image acquisition. Also, any high-level image analysis performed to ICUS images is not needed. Results are given for clinical image data of patients in order to validate the proposed method. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:860 / 868
页数:9
相关论文
共 50 条
  • [1] An off-line gating method for suppressing motion artifacts in intracoronary ultrasound image sequence
    Sun, Zheng
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2010, 21 (04): : 632 - 638
  • [2] Off-Line Development of Robot Motion Programs
    Moody, Dale R.
    WELDING JOURNAL, 2008, 87 (08) : 44 - 47
  • [3] The time course of off-line motor sequence learning
    Press, DZ
    Casement, MD
    Pascual-Leone, A
    Robertson, EM
    COGNITIVE BRAIN RESEARCH, 2005, 25 (01): : 375 - 378
  • [4] OFF-LINE METHODS FOR DETECTION AND CORRECTION OF EEG ARTIFACTS OF VARIOUS ORIGIN
    HATSKEVICH, CW
    ITKIS, ML
    MALOLETNEV, VI
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 1992, 12 (02) : 179 - 185
  • [5] OFF-LINE HANDLING WILL SET YOUR WORK IN MOTION
    DRURY, J
    METALWORKING PRODUCTION, 1979, 123 (09) : 192 - &
  • [6] Concept for an off-line gain stabilisation method
    Pommé, S
    Sibbens, G
    APPLIED RADIATION AND ISOTOPES, 2004, 60 (2-4) : 151 - 154
  • [7] A Robust Off-line Writer Identification Method
    Chen S.-M.
    Wang Y.-S.
    Zidonghua Xuebao/Acta Automatica Sinica, 2020, 46 (01): : 108 - 116
  • [8] Sequence Skill Acquisition and Off-Line Learning in Normal Aging
    Brown, Rachel M.
    Robertson, Edwin M.
    Press, Daniel Z.
    PLOS ONE, 2009, 4 (08):
  • [9] An Effective Simulated Annealing for Off-line Robot Motion Planning
    Figueroa, Andrea
    Montero, Elizabeth
    Riff, Maria-Cristina
    2017 IEEE 29TH INTERNATIONAL CONFERENCE ON TOOLS WITH ARTIFICIAL INTELLIGENCE (ICTAI 2017), 2017, : 967 - 971
  • [10] OFF-LINE PROGRAMMED MOTION PLANNING FOR INDUSTRIAL ROBOTS ON THE BASIS OF A FAULT COMPENSATED IDENTIFICATION METHOD
    BEHRENS, A
    THATER, G
    ROBOTERSYSTEME, 1992, 8 (04): : 209 - 219