Front end readout electronics for the CMS Hadron Calorimeter

被引:0
|
作者
Shaw, TM [1 ]
Baumbaugh, A [1 ]
Boubekeur, A [1 ]
Elias, JE [1 ]
Hoff, J [1 ]
Holm, S [1 ]
Los, S [1 ]
Rivetta, C [1 ]
Ronzhin, A [1 ]
Whitmore, J [1 ]
Zimmerman, T [1 ]
Yarema, RJ [1 ]
机构
[1] Fermilab Natl Accelerator Lab, Batavia, IL 60510 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The front-end electronics for the CMS Hadron Calorimeter provides digitized data at the beam interaction rate of 40 MHz, Analog signals provided by hybrid photodiodes (HPDs) or photomultiplier tubes (PMTs) are digitized and the data is sent off board through serialized fiber optic links running at 1600 Mbps. In order to maximize the input signal, the front-end electronics are housed on the detector in close proximity to the scintillating fibers or phototubes. To fit the electronics into available space, custom crates, backplanes and cooling methods have had to be developed. During the expected ten-year lifetime, the front-end readout electronics will exist in an environment where radiation levels approach 330 rads and the neutron fluence will be 1.3E11 n/cm(2). For this reason, the design approach relies heavily upon custom radiation tolerant ASICs. This paper will present the system architecture of the front-end readout crates and describe our results with early prototypes.
引用
收藏
页码:194 / 197
页数:4
相关论文
共 50 条
  • [31] Performance study of HGCROC-v2: the front-end electronics for the CMS High Granularity Calorimeter
    Thienpont, D.
    de la Taille, C.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (04):
  • [32] Front-end electronics for the readout of CdZnTe sensors
    Moraes, Danielle
    Nygard, Einar
    Rudge, Alan
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 348 - 352
  • [33] Physics capabilities of the CMS hadron calorimeter
    Wu, WM
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2000, : 394 - 403
  • [34] Overview of the readout of the CMS electromagnetic calorimeter
    Ille, B
    PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 1998, : 439 - 450
  • [35] Silicon photomultipliers for the CMS hadron calorimeter
    Freeman, Jim
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3): : 393 - 395
  • [36] Readout electronics for the CMS Phase II Endcap Calorimeter: system overview and prototyping experience
    Strobbe, N.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (04):
  • [37] Selective readout in the CMS electromagnetic calorimeter
    Monteiro, T
    PROCEEDINGS OF THE FIFTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 1999, : 247 - 250
  • [38] On-beam system test of the new readout electronics for the CMS Electromagnetic Calorimeter upgrade
    Campana, Mattia
    JOURNAL OF INSTRUMENTATION, 2024, 19 (02)
  • [39] A HADRON CALORIMETER WITH WAVELENGTH SHIFTER READOUT
    BOTNER, O
    DAGAN, S
    FABJAN, CW
    JEFFREYS, P
    KESSELER, G
    MOLZON, W
    OREN, Y
    ROSSELET, L
    SMITH, SD
    VANDERLANS, J
    WANG, CJ
    WILLIS, WJ
    WITZELING, W
    WOODY, C
    NUCLEAR INSTRUMENTS & METHODS, 1981, 179 (01): : 45 - 54
  • [40] A CONCEPT FOR A HADRON CALORIMETER WITH PHOTODIODE READOUT
    DIETL, H
    EIGEN, G
    FONSECA, V
    LORENZ, E
    MAGERAS, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 235 (02): : 314 - 318