beta-gamma coincidence; mu-gamma anticoincidence; High resolution; High-purity germanium; Silicon surface barrier; Radioxenon; Multi-parameter; List mode; Conversion electron; TEST-BAN TREATY; INTERNATIONAL MONITORING-SYSTEM; RADIOACTIVE XENON ISOTOPES; ACCIDENTAL COINCIDENCES; QUANTIFICATION LIMITS; DELAYED COINCIDENCE; PHOSWICH DETECTORS; COUNTING SYSTEM; GAS; RADIONUCLIDES;
D O I
10.1016/j.nima.2010.06.227
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A high-resolution beta-gamma coincidence measurement system has been developed by combining a high-purity broad energy germanium and a silicon surface barrier detector. The system is intended for calibration of reference spikes and re-measurement of CTBT samples, by detection of coincident beta-gamma or conversion electron and X-ray radiation of the four radioxenon isotopes (131m)Xe, (133m)Xe, (133)Xe and (135)Xe. The use of a high-resolution, list-mode, multi-parameter data acquisition system allows off-line setup and optimization of the (anti)coincidence. A (166m)Ho beta-gamma source has been produced and validated for energy calibration and system check. The beta-gamma coincidence has been further enhanced by a cosmic muon veto based on six plastic scintillation detectors. The mu-gamma anticoincidence has been implemented using a 50 ns resolution real-time clock for time spectroscopy. This method has been verified by running conventional TAC-ADC (combined time-amplitude and analog-digital converter) based time spectroscopy in parallel. The whole measurement system has been characterized, by measuring various radioxenon spikes and backgrounds with and without (anti)coincidence. Peak efficiencies and minimum detectable activities (MDA) for the main radioxenon isotopes have been determined. Application of mu-gamma anticoincidence reduced the MDA by about a factor of two for all four radioxenon isotopes. Complementary adoption of beta-gamma coincidence further reduced the MDA for the metastable isotopes by more than an order of magnitude. The MDA for (135)Xe reaches about 6 mBq after 1 day of measurement. For (131m)Xe, (133)Xe and (133m)Xe a MDA of about 2 mBq is obtained after one week measurement. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:478 / 488
页数:11
相关论文
共 50 条
  • [11] Design of Multi-Parameter Embedded Biological Information Measurement System
    Zhao Jinchuang
    Zhang Hao
    Fu Wenli
    Zou Xingxing
    PROCEEDINGS OF THE 2016 12TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2016, : 473 - 476
  • [12] Multi-parameter and multi-point measurement
    Hanson, R.K.
    Baer, D.S.
    McMillin, B.K.
    Arroyo, P.
    Berichte der Bunsengesellschaft fuer Physikalische Chemie, 1993, 97 (12):
  • [13] Multi-parameter measurement of a multi-point high-frequency vibration signal in an OFDR system
    Song, Muping
    Chen, Ge
    Cui, Enxue
    Zhang Yuxin
    APPLIED OPTICS, 2022, 61 (19) : 5675 - 5680
  • [14] Convex Optimization of Coincidence Time Resolution for a High-Resolution PET System
    Reynolds, Paul D.
    Olcott, Peter D.
    Pratx, Guillem
    Lau, Frances W. Y.
    Levin, Craig S.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (02) : 391 - 400
  • [15] MULTI-PARAMETER SURFACE TEXTURE MEASUREMENT
    FREYBERG, DW
    RESEARCH-DEVELOPMENT, 1974, 25 (05): : 41 - &
  • [16] High spatial resolution distributed fiber system for multi-parameter sensing based on modulated pulses
    Zhang, Jingdong
    Zhu, Tao
    Zhou, Huan
    Huang, Shihong
    Liu, Min
    Huang, Wei
    OPTICS EXPRESS, 2016, 24 (24): : 27482 - 27493
  • [17] Determination of trace elements using multi-parameter coincidence spectrometry
    Hatsukawa, Y.
    Toh, Y.
    Oshima, M.
    Kimura, A.
    Gharaie, M. Hosein Mahmudy
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 271 (01) : 43 - 45
  • [18] Determination of trace elements using multi-parameter coincidence spectrometry
    Y. Hatsukawa
    Y. Toh
    M. Oshima
    A. Kimura
    M. Hosein Mahmudy Gharaie
    Journal of Radioanalytical and Nuclear Chemistry, 2007, 271 : 43 - 45
  • [19] A HIGH-RESOLUTION SYSTEM FOR PARTICLE-GAMMA COINCIDENCE MEASUREMENTS
    AMEZQUITA, J
    MOORE, CF
    LIEB, KP
    KULLECK, JG
    KOIKE, M
    WATSON, CE
    NUCLEAR PHYSICS A, 1970, A146 (01) : 26 - +
  • [20] Design of a small marine multi-parameter measurement system based on Rpi
    Liu Wei
    Zhang Yu-jie
    Zhang Zi-qi
    Zou Da-peng
    INTERNATIONAL CONFERENCE ON SENSORS AND INSTRUMENTS (ICSI 2021), 2021, 11887