Reduction of motion blurring artifacts using respiratory gated CT in sinogram space: A quantitative evaluation

被引:17
|
作者
Lu, W
Parikh, PJ
Hubenschmidt, JP
Politte, DG
Whiting, BR
Bradley, JD
Mutic, S
Low, DA [1 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Dept Radiol, St Louis, MO 63110 USA
关键词
motion artifact; CT; respiratory gating; sinogram;
D O I
10.1118/1.2074187
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Techniques have been developed for reducing motion blurring artifacts by using respiratory gated computed tomography (CT) in sinogram space and quantitatively evaluating the artifact reduction. A synthetic sinogram was built from multiple scans intercepting a respiratory gating window. A gated CT image was then reconstructed using the filtered back-projection algorithm. Wedge phantoms, developed for quantifying the motion artifact reduction, were scanned while being moved using a computer-controlled linear stage. The resulting artifacts appeared between the high and low density regions as an apparent feature with a Hounsfield value that was the average of the two regions. A CT profile through these regions was fit using two error functions, each modeling the partial-volume averaging characteristics for the unmoving phantom. The motion artifact was quantified by determining the apparent distance between the two functions. The blurring artifact had a linear relationship with both the speed and the tangent of the wedge angles. When gating was employed, the blurring artifact was reduced systematically at the air-phantom interface. The gated image of phantoms moving at 20 mm/s showed similar blurring artifacts as the nongated image of phantoms moving at 10 mm/s. Nine patients were also scanned using the synchronized respiratory motion technique. Image artifacts were evaluated in the diaphragm, where high contrast interfaces intercepted the imaging plane. For patients, this respiratory gating technique reduced the blurring artifacts by 9%-41% at the lung-diaphragm interface. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:3295 / 3304
页数:10
相关论文
共 50 条
  • [1] Reduction of motion blurring artifact using respiratory gated CT: A quantitative evaluation
    Lu, W
    Parikh, P
    Hubenschmidt, J
    Politte, D
    Whiting, B
    Bradley, J
    Low, D
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2056 - 2056
  • [2] Investigation of gated cone-beam CT to reduce respiratory motion blurring
    Kincaid, Russell E., Jr.
    Yorke, Ellen D.
    Goodman, Karyn A.
    Rimner, Andreas
    Wu, Abraham J.
    Mageras, Gig S.
    [J]. MEDICAL PHYSICS, 2013, 40 (04)
  • [3] Investigation of Gated Cone-Beam CT to Reduce Respiratory Motion Blurring
    Kincaid, R.
    Yorke, E.
    Rimner, A.
    Mageras, G.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [4] Reduction of CT artifacts due to respiratory motion in a slowly rotating SPECT/CT
    Erlandsson, Kjell
    Nunez, Margarita
    Kruppa, Declan
    Hutton, Brian F.
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3050 - 3053
  • [5] Motion correction for gated PET using sinogram registration
    Detorie, Nicole C.
    Dahlbom, Magnus
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3577 - 3582
  • [6] Reduction of in-plane breathing motion artifacts using optimized-angle sinogram reconstruction
    Low, D.
    Parikh, P.
    Whiting, B.
    Mutic, S.
    Hubenschmidt, J.
    Malinowski, K.
    Lu, W.
    Bradley, J.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2346 - 2346
  • [7] Investigation of Gated Cone-Beam CT to Reduce Respiratory Motion Blurring in Images of Thorax and Abdomen
    Kincaid, R.
    Yorke, E.
    Goodman, K.
    Rimner, A.
    Wu, A.
    Mageras, G.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3904 - 3904
  • [8] INVESTIGATION OF A GATED CONE-BEAM CT TECHNIQUE TO REDUCE RESPIRATORY MOTION BLURRING IN ABDOMINAL SITES
    Kincaid, R.
    Yorke, E.
    Goodman, K.
    Wu, A.
    Mageras, G.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S152 - S153
  • [9] Evaluation and reduction of respiratory motion artifacts in small animal SPECT with GATE
    Lee, C. -L.
    Park, S. -J.
    Kim, H. -J.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10
  • [10] Reduction of irregular breathing artifacts in respiration-correlated CT images using a respiratory motion model
    Hertanto, Agung
    Zhang, Qinghui
    Hu, Yu-Chi
    Dzyubak, Oleksandr
    Rimner, Andreas
    Mageras, Gig S.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3070 - 3079