Layer-by-layer self-assembly of functionalized graphene nanoplates for glucose sensing in vivo integrated with on-line microdialysis system

被引:76
|
作者
Gu, Hui [1 ,2 ]
Yu, Yanyan [1 ,2 ]
Liu, Xiaoqian [1 ,2 ]
Ni, Bing [3 ]
Zhou, Tianshu [4 ]
Shi, Guoyue [1 ,2 ]
机构
[1] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
[2] E China Normal Univ, Shanghai Key Lab Green Chem & Chem Proc, Shanghai 200062, Peoples R China
[3] E China Normal Univ, Dept Life Sci, Shanghai 200062, Peoples R China
[4] E China Normal Univ, Dept Environm Sci, Shanghai 200062, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2012年 / 32卷 / 01期
基金
中国国家自然科学基金;
关键词
{IL-RGO/S-RGO}(n); Functionalized graphene; On-line microdialysis system; Glucose biosensor; In vivo; ELECTROCHEMICAL METHOD; LARGE-AREA; FILMS; GRAPHITE; OXIDE; NANOSTRUCTURES; BIOSENSOR; LACTATE; SHEETS; CARBON;
D O I
10.1016/j.bios.2011.11.044
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this work, a novel amperometric biosensor for hydrogen peroxide was fabricated through the layer-by-layer (LBL) self-assembling of amine-terminated ionic liquid (IL-NH2), and sulfonic acid (SO3-) functionalized graphene by covalent bonding. The modification of the two functionalities introduced positive and negative charge onto the surface of graphene respectively, thus facilitating the formation of a multilayer film denoted with {IL-RGO/S-RGO}(n) through electrostatic interaction and further immobilization of glucose oxidase (GOx). The resulting {IL-RGO/S-RGO}(n)/GOx/Nafion biosensor displayed an excellent response to glucose at a potential of -200 mV. Combined with on-line microdialysis system, the glucose biosensor in the on-line system showed good linear range from 10 mu M to 500 mu M with the detection limit of 3.33 mu M (S/N =3). Consequently, the basal level of glucose in the striatum of anesthetic rats was calculated to be 0.376 +/- 0.028 mM (mean +/- s.d., n = 3). The {IL-RGO/S-RGO}(n)/GOx/Nafion biosensor was further applied for in vivo sensing of the glucose level in the striatum when rats received intraperitoneal (i.p.) injection of 30 mu L insulin, which resulted in an obvious decrease in the extracellular concentration of glucose within 30 min. The method was proved to be sensitive and reproducible, which enabled its promising application in physiology and pathology. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:118 / 126
页数:9
相关论文
共 50 条
  • [21] Graphene-Based Multilayers Constructed from Layer-by-Layer Self-Assembly Techniques
    Yu, Bing
    Liu, Xiaomian
    Cong, Hailin
    Yuan, Hua
    Wang, Dong
    Li, Zejing
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2014, 14 (02) : 1145 - 1153
  • [22] Layer-by-layer self-assembly of glucose oxidase with a poly(allylamine)ferrocene redox mediator
    Hodak, J
    Etchenique, R
    Calvo, EJ
    Singhal, K
    Bartlett, PN
    LANGMUIR, 1997, 13 (10) : 2708 - 2716
  • [23] Formation of thiol-functionalized silica films by layer-by-layer self-assembly and biomimetic silicification
    Yang, Sung Ho
    Ko, Eun Hyea
    Choi, Insung S.
    MACROMOLECULAR RESEARCH, 2011, 19 (05) : 511 - 514
  • [24] Polyelectrolyte-functionalized multiwalled carbon nanotubes: preparation, characterization and layer-by-layer self-assembly
    Kong, H
    Luo, P
    Gao, C
    Yan, D
    POLYMER, 2005, 46 (08) : 2472 - 2485
  • [25] Formation of thiol-functionalized silica films by layer-by-layer self-assembly and biomimetic silicification
    Sung Ho Yang
    Eun Hyea Ko
    Insung S. Choi
    Macromolecular Research, 2011, 19 : 511 - 514
  • [26] Layer-by-layer stacked graphene nanocoatings by Marangoni self-assembly for corrosion protection of stainless steel
    Chen Ye
    Yangguang Zhu
    Hongyan Sun
    Feiyue Chen
    Huifang Sun
    Wen Dai
    Qiuping Wei
    Li Fu
    Aimin Yu
    Shiyu Du
    Minghui Yang
    Liang-Feng Huang
    Jinhong Yu
    Nan Jiang
    Cheng-Te Lin
    Chinese Chemical Letters, 2021, 32 (01) : 501 - 505
  • [27] Layer-by-layer stacked graphene nanocoatings by Marangoni self-assembly for corrosion protection of stainless steel
    Ye, Chen
    Zhu, Yangguang
    Sun, Hongyan
    Chen, Feiyue
    Sun, Huifang
    Dai, Wen
    Wei, Qiuping
    Fu, Li
    Yu, Aimin
    Du, Shiyu
    Yang, Minghui
    Huang, Liang-Feng
    Yu, Jinhong
    Jiang, Nan
    Lin, Cheng-Te
    CHINESE CHEMICAL LETTERS, 2021, 32 (01) : 501 - 505
  • [28] A novel glucose biosensor based on the immobilization of glucose oxidase on layer-by-layer assembly film of copper phthalocyanine functionalized graphene
    Zhang, Yan-Qin
    Fan, You-Jun
    Cheng, Lei
    Fan, Li-Li
    Wang, Zhuo-Yuan
    Zhong, Jing-Ping
    Wu, Li-Na
    Shen, Xing-Can
    Shi, Zu-Jin
    ELECTROCHIMICA ACTA, 2013, 104 : 178 - 184
  • [29] Molecular sieving through 'layer-by-layer' self-assembly of polyelectrolytes and highly crosslinked graphene oxide
    Subhasish Maiti
    Suryasarathi Bose
    Functional Composite Materials, 3 (1):
  • [30] An ultrasensitive and low-cost graphene sensor based on layer-by-layer nano self-assembly
    Zhang, Bo
    Cui, Tianhong
    APPLIED PHYSICS LETTERS, 2011, 98 (07)