Lessons learned from inter-laboratory studies of carbon isotope analysis of honey

被引:13
|
作者
Dunn, Philip J. H. [1 ]
Hill, Sarah [1 ]
Cowen, Simon [1 ]
Goenaga-Infante, Heidi [1 ]
Sargent, Mike [1 ]
Goren, Ahmet Ceyhan [2 ,13 ]
Bilsel, Mine [2 ]
Simsek, Adnan [2 ]
Ogrinc, Nives [3 ]
Potocnik, Doris [3 ]
Armishaw, Paul [4 ]
Hai, Lu [5 ]
Konopelko, Leonid [6 ]
Chubchenko, Yan [6 ]
Chesson, Lesley A. [7 ]
van der Peijl, Gerard [8 ]
Blaga, Cornelia [8 ]
Posey, Robert [9 ]
Camin, Federica [10 ]
Chernyshev, Anatoly [11 ]
Chowdhury, Sadia A. [12 ]
机构
[1] LGC Ltd, Queens Rd, Teddington TW11 0LY, Middx, England
[2] TUBITAK UME, Gebze, Turkey
[3] Jozef Stefan Inst, Jamova 39, Ljubljana 1000, Slovenia
[4] Natl Measurement Inst Australia, 105 Delhi Rd, N Ryde, NSW 2113, Australia
[5] Natl Inst Metrol, 18 Bei San Huan Dong Lu, Beijing 100013, Peoples R China
[6] DI Mendeleev Inst Metrol, St Petersburg, Russia
[7] IsoForensics Inc, 421 Wakara Way,Suite 100, Salt Lake City, UT 84108 USA
[8] Netherlands Forens Inst, POB 24044, NL-2490 AA The Hague, Netherlands
[9] Innovat Ctr, Food Forens, Norwich Res Pk, Norwich NR4 7GJ, Norfolk, England
[10] FEM, Dept Food Qual & Nutr, Res & Innovat Ctr, Via E Mach 1, I-38010 San Michele All Adige, TN, Italy
[11] Ruakura Res Ctr, Analyt Labs, 10 Bisley Rd, Hamilton 3240, New Zealand
[12] Queensland Hlth Forens & Sci Serv, POB 594, Archerfield, Qld 4108, Australia
[13] Bezmialem Vakif Univ, Dept Analyt Chem, Fac Pharm, TR-34093 Istanbul, Turkey
基金
欧盟地平线“2020”;
关键词
Isotope ratio; Inter-laboratory comparison; Performance metrics; Metrology; RATIO MASS-SPECTROMETRY; MEASUREMENT UNCERTAINTY; CALIBRATION; GUIDELINES; DELTA-C-13; TOOL;
D O I
10.1016/j.scijus.2018.08.003
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Forensic application of carbon isotope ratio measurements of honey and honey protein to investigate the degree of adulteration with high fructose corn syrup or other C-4 plant sugars is well established. These measurements must use methods that exhibit suitable performance criteria, particularly with regard to measurement uncertainty and traceability - low levels of adulteration can only be detected by methods that result in suitably small measurement uncertainties such that differences of 1960 or less can be reliably detected. Inter-laboratory exercises are invaluable to assess the state-of-the art of measurement capabilities of laboratories necessary to achieve such performance criteria. National and designated metrology institutes from a number of countries recently participated in an inter-laboratory assessment (CCQM-K140) of stable carbon isotope ratio determination of bulk honey. The same sample material was distributed to a number of forensic isotope analysis laboratories that could not participate directly in the metrological comparison. The results from these studies have demonstrated that the majority of participants provided isotope delta values with acceptable performance metrics; that all participants ensured traceability of their results; and that where measurement uncertainties were reported; these were fit-for-purpose. A number of the forensic laboratories only reported precision rather than full estimates of measurement uncertainty and this was the major cause of the few instances of questionable performance metrics. Reporting of standard deviations in place of measurement uncertainties is common practice outside metrology institutes and the implications for interpretations of small differences in isotopic compositions are discussed. The results have also highlighted a number of considerations that are useful for organisers of similar inter-laboratory studies in the future.
引用
收藏
页码:9 / 19
页数:11
相关论文
共 50 条
  • [41] CRYOGLOBULIN EVALUATION: ANALYSIS OF INTRA-LABORATORY AND INTER-LABORATORY VARIABILITY
    Campioli, D.
    Natali, P.
    Debbia, D.
    Spinella, A.
    Sandri, G.
    Cerami, C.
    Scichilone, L.
    Fontana, F.
    Mascia, M. T.
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2018, 77 : 1473 - 1473
  • [42] Inter-laboratory studies: Improved results by application of strict good laboratory practice
    Arrighi, S
    Del Carlo, M
    Maggianetti, S
    Morelli, A
    Campani, M
    [J]. THROMBOSIS AND HAEMOSTASIS, 1999, : 570 - 570
  • [43] Inter-laboratory comparisons of the allergenic potential of proteins: Studies in mice
    Dearman, RJ
    Skinner, R
    Herouet, C
    Debruyne, E
    Kimber, I
    [J]. TOXICOLOGY, 2004, 194 (03) : 253 - 254
  • [44] Higher order inference for the consensus mean in inter-laboratory studies
    Sharma, Gaurav
    Mathew, Thomas
    [J]. BIOMETRICAL JOURNAL, 2011, 53 (01) : 128 - 136
  • [45] INTER-LABORATORY TRANSFER STUDIES WITH A CANDIDATE REFERENCE METHOD FOR UREA
    SAMPSON, EJ
    BAIRD, MA
    FAST, DM
    WITTE, DL
    [J]. CLINICAL CHEMISTRY, 1982, 28 (07) : 1558 - 1558
  • [46] Analysis of carbon nanotube levels in organic matter: an inter-laboratory comparison to determine best practice
    Devoy, Jerome
    Al-Abed, Souhail
    Cerdan, Benjamin
    Cho, Wan-Seob
    Dubuc, David
    Flahaut, Emmanuel
    Grenier, Katia
    Grossmann, Stephane
    Gulumian, Mary
    Jeong, Jiyoung
    Kim, Boo Wook
    Laycock, Adam
    Lee, Jong Seong
    Smith, Rachel
    Yang, Mei
    Yu, Il Je
    Zhang, Minfang
    Cosnier, Frederic
    [J]. NANOTOXICOLOGY, 2024, 18 (02) : 214 - 228
  • [48] WATER ANALYSIS IN SOUTH-AFRICA - INTER-LABORATORY COMPARISON STUDIES .3. NUTRIENT ANALYSIS
    SMITH, R
    [J]. WATER SA, 1978, 4 (04) : 161 - 168
  • [49] What We Have Learned from RENEB Inter-Laboratory Comparisons Since 2012 With Focus on ILC 2021
    Endesfelder, D.
    Oestreicher, U.
    Barquinero, J. F.
    Vral, A.
    Terzoudi, G.
    Moquet, J.
    Trompier, F.
    Wojcik, A.
    Abend, M.
    Port, M.
    [J]. RADIATION RESEARCH, 2023, 199 (06) : 616 - 627
  • [50] An inter-laboratory comparison assessing the quality of seawater carbon dioxide measurements
    Bockmon, Emily E.
    Dickson, Andrew G.
    [J]. MARINE CHEMISTRY, 2015, 171 : 36 - 43