Discrete cosine transform JPEG compression vs. 2D JPEG2000 compression: JNDmetrix visual discrimination model image quality analysis

被引:9
|
作者
Siddiqui, KM [1 ]
Johnson, JP [1 ]
Reiner, BI [1 ]
Siegel, EL [1 ]
机构
[1] VA Maryland Hlth Care Syst, Baltimore, MD 21201 USA
关键词
compression; radiography; PACS; visual discrimination model; discrete cosine transform; JPEG; 2000; image storage and transmission;
D O I
10.1117/12.596146
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The JPEG2000 compression standard is increasingly a preferred industry method for 2D image compression. Some vendors, however, continue to use proprietary discrete cosine transform (DCT) JPEG encoding. This study compares image quality in terms of just-noticeable differences (JNDs) and peak signal-to-noise ratios (PSNR) between DCT JPEG encoding and JPEG2000 encoding. Four computed tomography and 6 computed radiography studies were compressed using a proprietary DCT JPEG encoder and JPEG2000 standard compression. Image quality was measured in JNDs and PSNRs. The JNDmetrix computational visual discrimination model simulates known physiological mechanisms in the human visual system, including the luminance and contrast sensitivity of the eye and spatial frequency and orientation responses of the visual cortex. Higher JND values indicate that a human observer would be more likely to notice a significant difference between compared images. DCT JPEG compression showed consistently lower image distortions at lower compression ratios, whereas JPEG2000 compression showed benefit at higher compression ratios (> 50:1). The crossover occurred at ratios that varied among the images. The magnitude of any advantage of DCT compression at low ratios was often small. Interestingly, this advantage of DCT JPEG compression at lower ratios was generally not observed when image quality was measured in PSNRs. These results suggest that DCT JPEG may outperform JPEG2000 for compression ratios generally used in medical imaging and that the differences between DCT and JPEG2000 could be visible to observers and thus clinically significant.
引用
收藏
页码:202 / 207
页数:6
相关论文
共 50 条
  • [21] Wavelet Analysis and High Quality JPEG2000 Compression Using Daubechies Wavelet
    Khalid, Azra
    Afsheen, Uzma
    Baig, Saad Umer
    [J]. INTERNATIONAL CONFERENCE ON GRAPHIC AND IMAGE PROCESSING (ICGIP 2011), 2011, 8285
  • [22] JPEG2000 compression of thin-section CT images of the lung: Effect of compression ratio on image quality
    Ringl, Helmut
    Schernthaner, Ruediger E.
    Bankier, Alexander A.
    Weber, Michael
    Prokop, Mathias
    Herold, Christian J.
    Schaefer-Prokop, Cornelia
    [J]. RADIOLOGY, 2006, 240 (03) : 869 - 877
  • [23] JPEG2000 vs. full frame wavelet packet compression for smart card medical records
    Leehan, Joaquin Azpiroz
    Lerallut, Jean-Francois
    [J]. 2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 570 - 573
  • [24] EFFECTS OF LOSSY JPEG2000 COMPRESSION METHOD ON WORLDVIEW-2 IMAGE CLASSIFICATION
    Marsetic, Ales
    Kokalj, Ziga
    Ostir, Kristof
    [J]. GEODETSKI VESTNIK, 2012, 56 (02) : 275 - 289
  • [25] Study on medical ultrasonic echo image compression by JPEG2000 - Optimization and the subjective assessment of the quality
    Hamamoto, K
    [J]. PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 833 - 836
  • [26] Compression of high resolution 1D and 2D NMR data sets using JPEG2000
    Cobas, J. Carlos
    Tahoces, Pablo G.
    Fernandez, Isaac Iglesias
    Martin-Pastor, Manuel
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2008, 91 (02) : 141 - 150
  • [27] Compression of multi-slice CT: 2D vs. 3D JPEG 2000 and effects of slice thickness
    Siegel, E
    Siddiqui, K
    Johnson, J
    Crave, O
    Wu, ZY
    Dagher, J
    Bilgin, A
    Marcellin, M
    Nadar, M
    Reiner, B
    [J]. Medical Imaging 2005: PACS and Imaging Informatics, 2005, 5748 : 162 - 170
  • [29] Basic investigation on medical ultrasonic echo image compression by JPEG2000 - Availability of wavelet transform and ROI method
    Hamamoto, K
    Nishimura, T
    [J]. PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 2449 - 2452
  • [30] JPEG2000 3D compression vs 2D compression: An assessment of artifact amount and computing time in compressing thin-section abdomen CT images
    Kim, Bohyoung
    Lee, Kyoung Ho
    Kim, Kil Joong
    Richter, Thomas
    Kang, Heung-Sik
    Kim, So Yeon
    Kim, Young Hoon
    Seo, Jinwook
    [J]. MEDICAL PHYSICS, 2009, 36 (03) : 835 - 844