Comparison of glomerular filtration rate measurements with two plasma and single plasma sample methods in renal transplant cases with stable renal graft functions

被引:0
|
作者
Oner, Ali Ozan [1 ]
Aydin, Funda [2 ]
Ipekci, Tumay [3 ]
Sipahi, Murat [2 ]
Suleymanlar, Gultekin [4 ]
Gungor, Firat [2 ]
机构
[1] Afyon Kocatepe Univ, Sch Med, Dept Nucl Med, Afyon, Turkey
[2] Akdeniz Univ, Sch Med, Dept Nucl Med, TR-07058 Antalya, Turkey
[3] Baskent Univ, Sch Med, Alanya Practice & Res Ctr, Dept Urol, Alanya, Turkey
[4] Akdeniz Univ, Sch Med, Dept Internal Med, Div Nephrol, TR-07058 Antalya, Turkey
关键词
Glomerular filtration rate; Renal transplantation; Single plasma sample method; Two plasma sample method; PREDICTED CREATININE CLEARANCE; CHRONIC KIDNEY-DISEASE; DIABETIC-NEPHROPATHY; TC-99M-DTPA; CR-51-EDTA; RADIONUCLIDES; GUIDELINES; INJECTION; INULIN; DTPA;
D O I
10.1007/s12149-015-0954-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was planned to determine the efficacies of single plasma sample methods (SPSMs) in indicating glomerular filtration rate (GFR) by taking two plasma sample method (TPSM) as reference in the determination of the GFR in cases with clinically stable renal transplantation. Ninety-six renal transplantation cases (33 female, 63 male; age interval 18-67, mean age 37.46 +/- A 11.81 years) progressing stably clinically and as laboratory, with minimum 6 months after transplantation were included in the study. The GFR values of the cases were measured with SPSM and TPSM. It is observed that all SPSMs have a strong correlation with TPSM. Highest correlation was observed between Groth&Aasted SPSM and TPSM GFR (intraclass correlation coefficient: 0.965). In the analyses performed by using the Bland-Altman analysis, GFR values calculated by all SPSMs were concordant to the TPSM which is the gold standard method in 95 % confidence interval (average +/- A 1.96 standard deviation) and were within the clinically acceptable limits. The narrowest concordance interval was obtained between Groth&Aasted Tc-99 m DTPA SPSM and Tc-99 m DTPA TPSM..Besides, we have obtained the minimum bias and precision value by the Groth&Aasted method. As a result; we can see that all the SPSMs give reliable results in measuring GFR in cases with renal transplantation; besides, we suggest Groth&Aasted method as the first option.
引用
下载
收藏
页码:359 / 365
页数:7
相关论文
共 50 条
  • [21] Arterial stiffness and glomerular filtration rate decline in stable renal transplant recipients
    Canet, S.
    Parisotto, M.
    Vela, C.
    Mourad, G.
    JOURNAL OF HYPERTENSION, 2008, 26 : S217 - S217
  • [22] THE PLASMA CREATININE CONCENTRATION IS NOT AN ACCURATE REFLECTION OF THE GLOMERULAR-FILTRATION RATE IN STABLE RENAL-TRANSPLANT PATIENTS RECEIVING CYCLOSPORINE
    ROSS, EA
    WILKINSON, A
    HAWKINS, RA
    DANOVITCH, GM
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1987, 10 (02) : 113 - 117
  • [23] Comparison of glomerular filtration rate measured by plasma sample technique, Cockroft Gault method and Gates' method in voluntary kidney donors and renal transplant recipients
    Hephzibah, Julie
    Shanthly, Nylla
    Oommen, Regi
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2013, 28 (03): : 144 - 151
  • [24] Assessment of six different single plasma sample methods measuring glomerular filtration rate in children
    Ha, S.
    Lee, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S838 - S838
  • [25] MEASUREMENT OF GLOMERULAR FILTRATION RATE BY PLASMA IOHEXOL CLEARANCE WITH DIFFERENT SINGLE-SAMPLE METHODS
    Delanaye, Pierre
    Pottel, Hans
    Flamant, Martin
    Vidal-Petiot, Emmanuelle
    Lemoine, Sandrine
    Cavalier, Etienne
    Schaeffner, Elke
    Ebert, Natalie
    Dubourg, Laurence
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2018, 33
  • [26] Mosaic single plasma sample method for measuring glomerular filtration rate
    Kim, CK
    Religioso, DG
    NUCLEAR MEDICINE COMMUNICATIONS, 1996, 17 (11) : 952 - 956
  • [27] SINGLE PLASMA SAMPLE TECHNIQUE OF GLOMERULAR-FILTRATION RATE MEASUREMENT
    SUMMERVILLE, DA
    TREVES, ST
    JOURNAL OF NUCLEAR MEDICINE AND ALLIED SCIENCES, 1986, 30 (04): : 177 - 184
  • [28] Urineless estimation of glomerular filtration rate and renal plasma flow in the rat
    Ronnhedh, C
    Jaquenod, M
    Mather, LE
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 1996, 36 (03) : 123 - 129
  • [29] GLOMERULAR FILTRATION RATE AND RENAL PLASMA FLOW IN CHOLERA AND ACUTE GASTROENTERITIS
    BANERJEE, S
    GHOSH, H
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1957, 94 (04): : 668 - 670
  • [30] A COMPARISON OF METHODS IN MEASUREMENT OF EFFECTIVE RENAL PLASMA-FLOW AND GLOMERULAR-FILTRATION RATE IN CLINICAL-PRACTICE
    HIGA, T
    NAKATSU, M
    CLINICAL NUCLEAR MEDICINE, 1993, 18 (10) : 877 - 883