Application of ionic liquid modified carbon ceramic electrode for the sensitive voltammetric detection of rutin

被引:67
|
作者
Zhan, Tianrong [1 ,2 ]
Sun, Xiaoying [1 ]
Wang, Xiuzhen [1 ]
Sun, Wei [1 ]
Hou, Wanguo [1 ,2 ]
机构
[1] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Minist Educ, Key Lab Ecochem Engn, Qingdao 266042, Peoples R China
[2] Shandong Univ, Coll Chem & Chem Engn, Minist Educ, Key Lab Colloid & Interface Chem, Jinan 250000, Peoples R China
关键词
Rutin; Ionic liquid; Carbon ceramic electrode; Cyclic voltammetry; Differential pulse voltammetry; ELECTROCATALYTIC OXIDATION; ELECTROCHEMICAL-BEHAVIOR; AMPEROMETRIC DETECTION; COMPOSITE ELECTRODES; ASCORBIC-ACID; L-CYSTEINE; FILM; DOPAMINE;
D O I
10.1016/j.talanta.2010.07.083
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ionic liquid (IL) modified carbon ceramic electrode (CCE) was designed and further used for the voltarnmetric detection of rutin in this paper. IL-CCE was prepared by mixing graphite powder with 1-butyl-3-methylimidazolium tetrafluoroborate (EMIMBF4) doped silicate sol-gel matrix together and further characterized by different methods. Then electrochemical behaviors of rutin on the IL-CCE were investigated by different electrochemical methods such as cyclic voltamrnetry and differential pulse voltammetry (DPV). Due to the presence of IL in the CCE, an enhanced electrochemical response of rutin appeared with a pair of well-defined redox peaks in pH 2.5 phosphate buffer solution (PBS). The electrochemical behaviors of rutin on the IL-CCE were carefully investigated. Under the selected conditions the oxidation peak currents exhibited good linear relationship with the rutin concentration in the range from 0.3 to 100.0 mu mol/L with the detection limit as 0.09 mu mol/L (3 sigma). The proposed method was further applied to the rutin tablets sample detection with satisfactory results. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1853 / 1857
页数:5
相关论文
共 50 条
  • [21] A modified nanostructured graphene-gold nanoparticle carbon screen-printed electrode for the sensitive voltammetric detection of rutin
    Apetrei, I. M.
    Apetrei, C.
    [J]. MEASUREMENT, 2018, 114 : 37 - 43
  • [22] Graphene Nanosheets Modified Glassy Carbon Electrode as a Highly Sensitive and Selective Voltammetric Sensor for Rutin
    Du, Haijun
    Ye, Jianshan
    Zhang, Jiaqi
    Huang, Xiaodan
    Yu, Chengzhong
    [J]. ELECTROANALYSIS, 2010, 22 (20) : 2399 - 2406
  • [23] ROOM-TEMPERATURE IONIC LIQUID AND MULTI-WALLED CARBON NANOTUBE COMPOSITE MODIFIED CARBON-CERAMIC ELECTRODE AS A SENSITIVE VOLTAMMETRIC SENSOR FOR INDOMETHACIN
    Sarhangzadeh, Kianoush
    Mmohamma-Rezaei, Rahim
    Jabbri, Mohammad
    [J]. ANALYTICAL LETTERS, 2014, 47 (01) : 134 - 145
  • [24] Application of CdO nanoparticle ionic liquid modified carbon paste electrode as a high sensitive biosensor for square wave voltammetric determination of NADH
    Pahlavan, Ali
    Karimi-Maleh, Hassan
    Karimi, Fatemeh
    Amiri, Mohsen Aboukazempour
    Khoshnama, Zahra
    Shahmiri, Mandana Roodbari
    Keyvanfard, Mohsen
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 45 : 210 - 215
  • [25] DEVELOPMENT OF A MODIFIED CARBON ELECTRODE WITH IONIC LIQUID AND ITS APPLICATION FOR ELECTROCATALYTIC OXIDATION AND VOLTAMMETRIC DETERMINATION OF LEVODOPA
    Moncada, V.
    Alvarez-Lueje, A.
    [J]. JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2014, 59 (02): : 2516 - 2519
  • [26] Sensitive Voltammetric Determination of Cadmium(II) with 8-Hydroxyquinoline and Ionic Liquid Modified Carbon Paste Electrode
    Jia, Shaohui
    Gong, Shixing
    Cheng, Yong
    Wang, Huiyun
    Liu, Hejian
    Zhang, Bo
    Sun, Wei
    [J]. JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2014, 61 (11) : 1217 - 1222
  • [27] Sensitive voltammetric determination of epinephrine in the presence of acetaminophen at a novel ionic liquid modified carbon nanotubes paste electrode
    Tavana, Toktam
    Khalilzadeh, Mohammad A.
    Karimi-Maleh, Hassan
    Ensafi, Ali A.
    Beitollahi, Hadi
    Zareyee, Daryoush
    [J]. JOURNAL OF MOLECULAR LIQUIDS, 2012, 168 : 69 - 74
  • [28] Detection of rutin at DNA modified carbon paste electrode based on a mixture of ionic liquid and paraffin oil as a binder
    Yan Wang
    Huayu Xiong
    Xiuhua Zhang
    Shengfu Wang
    [J]. Microchimica Acta, 2010, 170 : 27 - 32
  • [29] Detection of rutin at DNA modified carbon paste electrode based on a mixture of ionic liquid and paraffin oil as a binder
    Wang, Yan
    Xiong, Huayu
    Zhang, Xiuhua
    Wang, Shengfu
    [J]. MICROCHIMICA ACTA, 2010, 170 (1-2) : 27 - 32
  • [30] Sensitive voltammetric method for the determination of naproxen at the surface of carbon nanofiber/gold/polyaniline nanocomposite modified carbon ionic liquid electrode
    Afzali, Moslem
    Jahromi, Zahra
    Nekooie, Reyhaneh
    [J]. MICROCHEMICAL JOURNAL, 2019, 145 : 373 - 379