Research on the Impact of Pre-tension on the Compliance of Artificial Blood Vessel

被引:0
|
作者
Zhang Wei [1 ]
Wang Lu [1 ]
机构
[1] Donghua Univ, Coll Text, Key Lab Text Sci & Technol, Minist Educ, Shanghai 201620, Peoples R China
关键词
vascular prostheses; compliance; pre-tension;
D O I
10.1109/3CA.2010.5533809
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Vascular compliance is one of the most important characterization indexes of vascular prostheses, which is defined as the ability of prostheses to elastically expand and contract in the circumferential direction in response to a pulsatile pressure. Our novel vascular compliance measure device is able to test the compliance of vascular prostheses in the simulated vivo environment of human body. The dynamic compliance testing method of ISO 7198 indicates that a lined rubber tube should be used to avoid water leakage of vascular prosthesis sample, and certain longitudinal preload should be applied to the test segment. But there are no precise preload indications for different types of vascular prosthesis. Through the test, vascular prostheses showed different compliance under different pre-tension with a lined rubber tube. The circumstance above is bound to affect the test results of dynamic compliance of vascular prostheses. This article aimed to do related research on experimental compliance of vascular prostheses in the simulated vivo environment and explore the mechanism of vascular compliance under pre-tension, then do some verification on related mechanism.
引用
收藏
页码:350 / 353
页数:4
相关论文
共 50 条
  • [31] Friction between single aramid fibres under pre-tension load
    Ismail, Nurhidayah
    de Rooij, Matthijn B.
    de Vries, Erik G.
    Zini, Nurul Hilwa Mohd
    Schipper, Dik J.
    [J]. TRIBOLOGY INTERNATIONAL, 2019, 137 : 236 - 245
  • [32] Effect of pre-tension on energy absorbed by fabric during projectile penetration
    Tapie, E.
    Guo, Y. B.
    Shim, V. P. W.
    [J]. INTERNATIONAL JOURNAL OF IMPACT ENGINEERING, 2018, 121 : 134 - 150
  • [33] Pre-tension generates strongly reversible adhesion of a spatula pad on substrate
    Chen, Bin
    Wu, Peidong
    Gao, Huajian
    [J]. JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2009, 6 (35) : 529 - 537
  • [34] Design and optimization of pre-tension forces in cable-stayed bridges
    Modano, M.
    Mascolo, I
    Fraternali, F.
    [J]. ADVANCES IN ENGINEERING MATERIALS, STRUCTURES AND SYSTEMS: INNOVATIONS, MECHANICS AND APPLICATIONS, 2019, : 1051 - 1055
  • [35] Effects of annealing, pre-tension and mounting on the hysteresis of polymer strain sensors
    Abang, Ada
    Webb, David J.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2014, 25 (01)
  • [36] PLCL-TPU bi-layered artificial blood vessel with compliance matching to host vessel
    Guan, Lihua
    Zhao, Huijing
    Wang, Kai
    Zhang, Ke-qin
    Meng, Kai
    [J]. JOURNAL OF BIOMATERIALS APPLICATIONS, 2023, 38 (02) : 194 - 202
  • [37] A non-contact method for estimating the pre-tension of a rectangular membrane structure
    Li, Dong
    Lai, Zhi-Chao
    Wang, Ying
    Zheng, Zhou-Lian
    [J]. INSIGHT, 2020, 62 (08) : 464 - 470
  • [38] Artificial blood vessel
    Kato, Masaaki
    [J]. JAPANESE JOURNAL OF ARTIFICIAL ORGANS, 2016, 45 (03): : 167 - 171
  • [39] Effects of Filament Pre-tension to the Characteristics of Solo-sirofil Composite yarn
    Yang, Rui-Hua
    Wu, Wei-Mian
    Wan, Yu-Qin
    Gao, Wei-Dong
    Wang, Hong-Bo
    Xie, Chun-Ping
    Wang, Shan-Yuan
    [J]. MATERIALS AND COMPUTATIONAL MECHANICS, PTS 1-3, 2012, 117-119 : 795 - +
  • [40] Temperature effect analysis of pre-tension and deformation characteristics of planar membrane structure
    Li Yanmin
    Qin Shuqi
    [J]. 2019 3RD INTERNATIONAL WORKSHOP ON RENEWABLE ENERGY AND DEVELOPMENT (IWRED 2019), 2019, 267