Metal artifact reduction using virtual monochromatic images for patients with pedicle screws implants on CT

被引:62
|
作者
Dong, Yue [1 ,2 ]
Shi, Ai Jun [1 ]
Wu, Jian Lin [3 ]
Wang, Ru Xin [1 ]
Sun, Li Fei [1 ]
Liu, Ai Lian [1 ]
Liu, Yi Jun [1 ]
机构
[1] Dalian Med Univ, Affiliated Hosp 1, Dept Radiol, Dalian 116011, Liaoning, Peoples R China
[2] DaLian Med Univ, Clin Oncol Coll, LiaoNing Canc Hosp, Dept Radiol, Shenyang 110042, Liaoning, Peoples R China
[3] Dalian Univ, Affiliated ZhongShan Hosp, Dept Radiol, Dalian 116001, Liaoning, Peoples R China
关键词
Spectral imaging; Virtual monochromatic image; Computed tomography; Metal artifacts; Pedicle screw; DUAL-ENERGY CT; SPINE; PLACEMENT; LUMBAR;
D O I
10.1007/s00586-015-4053-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
To evaluate the effect of spectral CT for metal artifact reduction in patients with pedicle screw. 45 patients with 119 pairs of pedicle screws underwent spectral CT examination. One set of conventional (140 kVp) polychromatic image and nine sets of virtual monochromatic images (60-140 keV) were obtained. The standard deviation (SD) of CT number in 12 locations around the implant and 1 on homogenous fat was measured to generate artifact index (AI). Objective assessment including AI, CT number and SD value was performed with independent t test and paired sample t test. Two radiologists independently reviewed the image quality, and Wilcoxon signed-rank test and kappa analysis were used for the subjective scores of image quality. The artifact index (AI) of all the regions decreased as keV increased. AIs of 100-140 keV were lower than that of 140 kVp images. At 120 keV there was no significant difference in CT numbers of psoas major muscle and vertebral canal between pedicle screw level and pedicle level, but a significant difference in SD value was determined between the two levels. The subjective scores at 100-140 keV were higher than the images at 140 kVp, and the highest subjective score of two observers and excellent interobserver agreement were found at 120 keV (kappa = 0.889). Virtual monochromatic images at high-energy levels have a well-concordant effect of removing metal artifacts, and 120 keV monochromatic images provided an accurate CT number and good subjective score.
引用
收藏
页码:1754 / 1763
页数:10
相关论文
共 50 条
  • [31] DiffMAR: A Generalized Diffusion Model for Metal Artifact Reduction in CT Images
    Cai, Tianxiao
    Li, Xiang
    Zhong, Chenglan
    Tang, Wei
    Guo, Jixiang
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2024, 28 (11) : 6712 - 6724
  • [32] Artifact reduction from dental implants using virtual monoenergetic reconstructions from novel spectral detector CT
    Hokamp, Nils Grosse
    Laukamp, K. R.
    Lennartz, S.
    Zopfs, D.
    Abdullayev, N.
    Neuhaus, V. F.
    Maintz, D.
    Borggrefe, J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 104 : 136 - 142
  • [33] Dosimetry Analysis On Proton Treatment Plan Using CT Images with Automatic Metal Artifact Reduction
    Wu, R.
    Hunter, R.
    Liu, A.
    Amin, M.
    Blanchard, P.
    Zhu, X.
    MEDICAL PHYSICS, 2017, 44 (06) : 2992 - 2992
  • [34] Metal artifacts in patients with large dental implants and bridges: combination of metal artifact reduction algorithms and virtual monoenergetic images provides an approach to handle even strongest artifacts
    Laukamp, Kai Roman
    Zopfs, David
    Lennartz, Simon
    Pennig, Lenhard
    Maintz, David
    Borggrefe, Jan
    Hokamp, Nils Grosse
    EUROPEAN RADIOLOGY, 2019, 29 (08) : 4228 - 4238
  • [35] Metal artifacts in patients with large dental implants and bridges: combination of metal artifact reduction algorithms and virtual monoenergetic images provides an approach to handle even strongest artifacts
    Kai Roman Laukamp
    David Zopfs
    Simon Lennartz
    Lenhard Pennig
    David Maintz
    Jan Borggrefe
    Nils Große Hokamp
    European Radiology, 2019, 29 : 4228 - 4238
  • [36] Metal artifact reduction and image quality evaluation of lumbar spine CT images using metal sinogram segmentation
    Kaewlek, Titipong
    Koolpiruck, Diew
    Thongvigitmanee, Saowapak
    Mongkolsuk, Manus
    Thammakittiphan, Sastrawut
    Tritrakarn, Siri-on
    Chiewvit, Pipat
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (06) : 649 - 666
  • [37] MR DISTORTION ARTIFACT CORRECTION FOR SPINE SABR PATIENTS WITH PEDICLE SCREWS
    Robertson, Andrew K. H.
    Wachowicz, Keith
    Stanescu, Teo
    Dunne, Emma
    Liu, Mitchell
    Martin, Monty
    Carolan, Hannah
    Thomas, Steven
    RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S40 - S40
  • [38] Assessing the Severity of Metal Artifacts and Detectability of Lesions in CT Metal Artifact Reduction Images
    Topbas, C.
    Dong, F.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [39] Reduction of Metal Artifact with Dual-Energy CT: Virtual Monospectral Imaging with Fast Kilovoltage Switching and Metal Artifact Reduction Software
    Pessis, Eric
    Sverzut, Jean-Michel
    Campagna, Raphael
    Guerini, Henri
    Feydy, Antoine
    Drape, Jean-Luc
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2015, 19 (05) : 446 - 455
  • [40] Combination of Iterative Metal Artifact Reduction and Virtual Monoenergetic Reconstruction Using Split-Filter Dual-Energy CT in Patients With Dental Artifact on Head and Neck CT
    Schmidt, Alexander Marcel Alfred
    Grunz, Jan-Peter
    Petritsch, Bernhard
    Gruschwitz, Philipp
    Knarr, Jonas
    Huflage, Henner
    Bley, Thorsten Alexander
    Kosmala, Aleksander
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (04) : 716 - 727