Non-Linear Optical Measurements Using a Scanned, Bessel Beam

被引:1
|
作者
Collier, Bradley B. [1 ]
Awasthi, Samir [1 ,2 ]
Lieu, Deborah K. [3 ]
Chan, James W. [1 ,4 ]
机构
[1] Univ Calif Davis, Ctr Biophoton, Davis, CA 95616 USA
[2] Univ Calif Davis, Dept Biomed Engn, Davis, CA USA
[3] Univ Calif Davis, Dept Internal Med, Davis, CA USA
[4] Univ Calif Davis, Dept Pathol & Lab Med, Davis, CA USA
基金
美国国家科学基金会;
关键词
non-linear optics; Bessel beam; light-sheet; microfluidic; flow cytometry; MULTIPHOTON FLOW-CYTOMETRY; FLUORESCENCE;
D O I
10.1117/12.2079711
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Oftentimes cells are removed from the body for disease diagnosis or cellular research. This typically requires fluorescent labeling followed by sorting with a flow cytometer; however, possible disruption of cellular function or even cell death due to the presence of the label can occur. This may be acceptable for ex vivo applications, but as cells are more frequently moving from the lab to the body, label-free methods of cell sorting are needed to eliminate these issues. This is especially true of the growing field of stem cell research where specialized cells are needed for treatments. Because differentiation processes are not completely efficient, cells must be sorted to eliminate any unwanted cells (i.e. un-differentiated or differentiated into an unwanted cell type). In order to perform label-free measurements, non-linear optics (NLO) have been increasingly utilized for single cell analysis because of their ability to not disrupt cellular function. An optical system was developed for the measurement of NLO in a microfluidic channel similar to a flow cytometer. In order to improve the excitation efficiency of NLO, a scanned Bessel beam was utilized to create a light-sheet across the channel. The system was tested by monitoring twophoton fluorescence from polystyrene microbeads of different sizes. Fluorescence intensity obtained from light-sheet measurements were significantly greater than measurements made using a static Gaussian beam. In addition, the increase in intensity from larger sized beads was more evident for the light-sheet system.
引用
下载
收藏
页数:6
相关论文
共 50 条
  • [11] Non-linear optical measurements on single molecules in solids at low temperatures
    Jelezko, F
    Lounis, B
    Orrit, M
    OPTICAL MATERIALS, 1998, 9 (1-4) : 381 - 385
  • [12] LASSO with Non-linear Measurements is Equivalent to One With Linear Measurements
    Thrampoulidis, Christos
    Abbasi, Ehsan
    Hassibi, Babak
    ADVANCES IN NEURAL INFORMATION PROCESSING SYSTEMS 28 (NIPS 2015), 2015, 28
  • [13] Non-linear optical microscopy
    Webb, WW
    BIOPHYSICAL JOURNAL, 1996, 70 (02) : WAMS1 - WAMS1
  • [14] NON-LINEAR OPTICAL INTERFACES
    SMITH, PW
    TOMLINSON, WJ
    APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1982, 28 (2-3): : 138 - 139
  • [15] NON-LINEAR OPTICAL INTERFEROMETER
    HOPF, FA
    CERVANTES, M
    APPLIED OPTICS, 1982, 21 (04) : 668 - 677
  • [16] Optical rectification using bessel femtosecond beam
    Liang X.
    Li Y.
    Xu S.
    Cao H.
    Hu M.
    Chai L.
    Wang Q.
    Guangxue Xuebao/Acta Optica Sinica, 2016, 36 (10):
  • [17] Optical micromanipulation using a Bessel light beam
    Arlt, J
    Garces-Chavez, V
    Sibbett, W
    Dholakia, K
    OPTICS COMMUNICATIONS, 2001, 197 (4-6) : 239 - 245
  • [18] Modal identification of non-linear structures using temporal measurements
    Raynaud, JL
    Perriot, A
    Fillod, R
    MECANIQUE INDUSTRIELLE ET MATERIAUX, 1997, 50 (01): : 27 - 29
  • [19] Non-Linear Beam Tracing on a GPU
    Liu, Baoquan
    Wei, Li-Yi
    Yang, Xu
    Ma, Chongyang
    Xu, Ying-Qing
    Guo, Baining
    Wu, Enhua
    COMPUTER GRAPHICS FORUM, 2011, 30 (08) : 2156 - 2169
  • [20] Non-linear modelling of a cracked beam
    Crespo, P
    Ruotolo, R
    Surace, C
    PROCEEDINGS OF THE 14TH INTERNATIONAL MODAL ANALYSIS CONFERENCE, VOLS I & II, 1996, 2768 : 1017 - 1022