Non-Linear Optical Measurements Using a Scanned, Bessel Beam

被引:1
|
作者
Collier, Bradley B. [1 ]
Awasthi, Samir [1 ,2 ]
Lieu, Deborah K. [3 ]
Chan, James W. [1 ,4 ]
机构
[1] Univ Calif Davis, Ctr Biophoton, Davis, CA 95616 USA
[2] Univ Calif Davis, Dept Biomed Engn, Davis, CA USA
[3] Univ Calif Davis, Dept Internal Med, Davis, CA USA
[4] Univ Calif Davis, Dept Pathol & Lab Med, Davis, CA USA
基金
美国国家科学基金会;
关键词
non-linear optics; Bessel beam; light-sheet; microfluidic; flow cytometry; MULTIPHOTON FLOW-CYTOMETRY; FLUORESCENCE;
D O I
10.1117/12.2079711
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Oftentimes cells are removed from the body for disease diagnosis or cellular research. This typically requires fluorescent labeling followed by sorting with a flow cytometer; however, possible disruption of cellular function or even cell death due to the presence of the label can occur. This may be acceptable for ex vivo applications, but as cells are more frequently moving from the lab to the body, label-free methods of cell sorting are needed to eliminate these issues. This is especially true of the growing field of stem cell research where specialized cells are needed for treatments. Because differentiation processes are not completely efficient, cells must be sorted to eliminate any unwanted cells (i.e. un-differentiated or differentiated into an unwanted cell type). In order to perform label-free measurements, non-linear optics (NLO) have been increasingly utilized for single cell analysis because of their ability to not disrupt cellular function. An optical system was developed for the measurement of NLO in a microfluidic channel similar to a flow cytometer. In order to improve the excitation efficiency of NLO, a scanned Bessel beam was utilized to create a light-sheet across the channel. The system was tested by monitoring twophoton fluorescence from polystyrene microbeads of different sizes. Fluorescence intensity obtained from light-sheet measurements were significantly greater than measurements made using a static Gaussian beam. In addition, the increase in intensity from larger sized beads was more evident for the light-sheet system.
引用
下载
收藏
页数:6
相关论文
共 50 条
  • [1] Non-Linear Optical Flow Cytometry Using a Scanned, Bessel Beam Light-Sheet
    Collier, Bradley B.
    Awasthi, Samir
    Lieu, Deborah K.
    Chan, James W.
    SCIENTIFIC REPORTS, 2015, 5
  • [2] Non-Linear Optical Flow Cytometry Using a Scanned, Bessel Beam Light-Sheet
    Bradley B. Collier
    Samir Awasthi
    Deborah K. Lieu
    James W. Chan
    Scientific Reports, 5
  • [3] OPTICAL MEASUREMENTS OF NON-LINEAR POLARIZABILITIES
    HAUCHECORNE, G
    KERHERVE, F
    MAYER, G
    JOURNAL DE PHYSIQUE, 1971, 32 (01): : 47 - +
  • [4] ON A NON-LINEAR BESSEL EQUATION
    MILES, JW
    SIAM JOURNAL ON APPLIED MATHEMATICS, 1982, 42 (01) : 109 - 112
  • [5] Calculation of non-linear fundamental frequency of a cantilever beam using non-linear stiffness
    Pany, C
    Rao, GV
    JOURNAL OF SOUND AND VIBRATION, 2002, 256 (04) : 787 - 790
  • [6] NON-LINEAR DISTORTIONS OF SCANNED LIGHT-BEAMS
    SUKHORUKOV, AP
    SHUMILOV, EN
    KVANTOVAYA ELEKTRONIKA, 1979, 6 (05): : 986 - 995
  • [7] MEASUREMENTS OF NON-LINEAR OPTICAL POLARIZABILITIES FOR 12 SMALL MOLECULES
    WARD, JF
    MILLER, CK
    PHYSICAL REVIEW A, 1979, 19 (02): : 826 - 833
  • [8] Microwave measurements - Non-linear measurements
    Camarchia, Vittorio
    Teppati, Valeria
    Corbellini, Simone
    Pirola, Marco
    IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2007, 10 (03) : 34 - 39
  • [9] NON-LINEAR BEAM STATICS
    BUFLER, H
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK, 1980, 60 (6BIS): : T108 - T112
  • [10] Biological video reconstruction using linear or non-linear Fourier measurements
    Le Montagner, Yoann
    Angelini, Elsa
    Olivo-Marin, Jean-Christophe
    WAVELETS AND SPARSITY XV, 2013, 8858