Application of tunable diode laser absorption spectroscopy for planetary studies, on lander board for planned missions to Moon, Mars and Venus

被引:0
|
作者
Vinogradov, I. I. [1 ]
Barke, V. V. [1 ]
Kazakov, V. A. [1 ]
Lebedev, Yu. V. [1 ]
Rodin, A. V. [1 ,2 ]
Roste, O. Z. [1 ]
Benderov, O. V. [2 ]
Klimchuk, A. Yu. [2 ]
Semenov, V. M. [2 ]
Zakharova, A. A. [2 ]
Kalyuzhnyi, A. V. [3 ]
Nadezhdinskii, A. I. [4 ]
Ponurovskiy, Ya. Ya. [4 ]
Spiridonov, V. V. [4 ]
Cousin, J. [5 ]
Durry, G. [5 ]
Joly, L. [5 ]
机构
[1] Russian Acad Sci IKI RAS, Space Res Inst, 84-32 Profsoyuznaya Str, Moscow 117997, Russia
[2] MIPT, Inst Sky Dr 9, Dolgoprudnyi, Moscow Region, Russia
[3] Special Design Bur Space Device Engn IKI RAS, Tarusa 249100, Kaluga Region, Russia
[4] Russian Acad Sci GPI RAS, Prokhorov Gen Phys Inst, Vavilov Str 38, Moscow 119991, Russia
[5] Univ Reims, CNRS, GSMA, UMR 7331, BP 1039, F-51687 Reims 2, France
来源
2016 INTERNATIONAL CONFERENCE LASER OPTICS (LO) | 2016年
关键词
tunable diode laser absorption spectroscopy; lander probes; planetary studies;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In a couple of years, researchers of IKI RAS, together with colleagues from MIPT, GPI RAS, and from the French GSMA team are developing TDLAS instruments for carrying out in situ measurements for several future space missions to our neighbor planets. In the report, we discuss TDLAS instrument adaptation for actual lander probes, scheduled for research missions to Moon, Mars and Venus.
引用
收藏
页数:1
相关论文
共 27 条
  • [21] Diagnostic studies of H2-Ar-N2 microwave plasmas containing methane or methanol using tunable infrared diode laser absorption spectroscopy
    Hempel, F
    Davies, PB
    Loffhagen, D
    Mechold, L
    Röpcke, J
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2003, 12 (04): : S98 - S110
  • [22] Simulation studies of multi-line line-of-sight tunable-diode-laser absorption spectroscopy performance in measuring temperature probability distribution function
    张光乐
    刘建国
    阚瑞峰
    许振宇
    Chinese Physics B, 2014, 23 (12) : 213 - 218
  • [23] Studies on gas concentration reconstruction methods for simultaneous temperature and H2O concentration tomographic imaging in a flame based on tunable diode laser absorption spectroscopy
    Zhai, Yunchu
    Wang, Fei
    OPTICAL ENGINEERING, 2021, 60 (02)
  • [24] Single-frequency Sb-based distributed-feedback lasers emitting at 2.3 μm above room temperature for application in tunable diode laser absorption spectroscopy
    Salhi, Abdelmagid
    Barat, David
    Romanini, Daniele
    Rouillard, Yves
    Ouvrard, Aimeric
    Werner, Ralph
    Seufert, Jochen
    Koeth, Johannes
    Vicet, Aurore
    Garnache, Arnaud
    APPLIED OPTICS, 2006, 45 (20) : 4957 - 4965
  • [25] RETRACTED: Comparison and application of wavelet transform and Kalman filtering for denoising in δ13CO2 measurement by tunable diode laser absorption spectroscopy at 2.008 μm (Retracted Article)
    Niu, Ming-sheng
    Han, Pei-gao
    Song, Lian-ke
    Hao, Dian-zhong
    Zhang, Jing-hu
    Ma, Lili
    OPTICS EXPRESS, 2017, 25 (20): : A896 - A905
  • [26] Flash photolysis/tunable diode laser absorption spectroscopy studies of HCl as a product of the reactions: Cl+C2H6 and Cl+CH3CHO
    KegleyOwen, CS
    Tyndall, GS
    Orlando, JJ
    Fried, A
    APPLICATION OF TUNABLE DIODE AND OTHER INFRARED SOURCES FOR ATMOSPHERIC STUDIES AND INDUSTRIAL PROCESS MONITORING, 1996, 2834 : 110 - 119
  • [27] RETRACTION: Comparison and application of wavelet transform and Kalman filtering for denoising in δ13CO2 measurement by tunable diode laser absorption spectroscopy at 2.008 μm (Retraction of Vol 25, Pg A896, 2017)
    Niu, Ming-sheng
    Han, Pei-gao
    Song, Lian-ke
    Hao, Dian-zhong
    Zhang, Jing-hu
    Ma, Lili
    OPTICS EXPRESS, 2019, 27 (12): : A860 - A860