Airborne Asbestos Fibers Detection in Microscope Images using re-initialization free Active Contours

被引:1
|
作者
Theodosiou, Zenonas [1 ]
Tsapatsoulis, Nicolas [1 ]
Bujak-Pietrek, Stella [2 ]
Szadkowska-Stanczyk, Irena [2 ]
机构
[1] Cyprus Univ Technol, Dept Commun & Internet Studies, CY-3603 Limassol, Cyprus
[2] Nofer Inst Occupat Med, Dept Environ Hlth Hazards, Aerosol Lab, PL-91348 Lodz, Poland
关键词
D O I
10.1109/IEMBS.2010.5626630
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Breathing in asbestos fibers can lead to a number of diseases, the fibers become trapped in the lung and cannot be removed by either coughing or the person's immune system. Atmospheric concentrations of carcinogenic asbestos fibers, have traditionally been measured visually using phase contrast microscopy. However, because this measurement method requires great skill, and has poor reproducibility and objectivity, the development of automatic counting methods has been long anticipated. In this paper we proposed an automated fibers detection method based on a variational formulation of geometric active contours that forces the level set function to be close to signed distance function and therefore completely eliminates the need of the costly re-initialization procedure. The method was evaluated using a ground truth of 29 manually annotated images. The results were encouraging for the further development of the proposed method.
引用
收藏
页码:4785 / 4788
页数:4
相关论文
共 33 条
  • [31] Real-time free space detection and navigation using omnidirectional vision and parametric and geometric active contours
    Merveilleux, Pauline
    Labbani-Igbida, Ouiddad
    Mouaddib, El Mustapha
    [J]. 2011 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2011,
  • [32] Automated detection of the carotid artery wall in longitudinal B-mode images using active contours initialized by the Hough transform
    Matsakou, A. I.
    Golemati, S.
    Stoitsis, J. S.
    Nikita, K. S.
    [J]. 2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 571 - 574
  • [33] Automated detection of the carotid artery wall in B-mode ultrasound images using active contours initialized by the Hough transform
    Stoitsis, J.
    Golemati, S.
    Kendros, S.
    Nikita, K. S.
    [J]. 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-8, 2008, : 3146 - 3149