The CDF silicon detector: Performance and longevity

被引:0
|
作者
Pronko, Alexandre [1 ]
机构
[1] Fermilab Natl Accelerator Lab, Batavia, IL 60510 USA
关键词
CDF; silicon detectors; radiation hardness;
D O I
10.1016/j.nima.2007.07.140
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The CDF silicon vertex detector is one of the largest operating silicon detectors in particle physics. Its silicon sensors have 722,432 channels readout by 5456 chips and cover an area of 6m(2). The detector is used for precision tracking and in the hardware trigger for events with a displaced vertex. This paper includes a brief review of the detector performance and mainly focuses on issues of longevity and effects of radiation damage. An analysis of the time evolution of depletion voltages and signal-to-noise ratios indicates that the CDF silicon detector should outlast the Tevatron Run II without major degradation of performance. Published by Elsevier B.V.
引用
收藏
页码:339 / 342
页数:4
相关论文
共 50 条
  • [41] Radiation Life of the CDF Run II Silicon Detector
    Redondo, Ignacio
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 503 - 506
  • [42] The CDF RUN II Silicon Detector: Aging Studies
    Redondo Fernandez, Ignacio
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 451 - 455
  • [43] CDF SVX II upgrade silicon detector: Silicon sensors performances
    Purdue Univ, West Lafayette, United States
    Nucl Instrum Methods Phys Res Sect A, 1-3 (112-116):
  • [44] Operational Experience with the CDF Run II Silicon Detector
    Mathis, Mark
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 745 - 746
  • [45] The SVX II silicon vertex detector upgrade at CDF
    Antos, J
    Chao, HY
    Chang, P
    Cheng, MT
    Chu, ML
    Guo, RS
    Ho, CL
    Teng, PK
    Wang, MJ
    Wu, SC
    Yeh, GP
    Yeh, P
    Andressen, J
    Barsotti, E
    Bowden, M
    Cihangir, S
    Gonzalez, H
    Grimm, C
    Haynes, B
    Hrycyk, M
    Howell, J
    Husby, D
    Knopf, W
    Lindenmeyer, M
    Ratzmann, P
    Sarge, J
    Spalding, J
    Spiegel, L
    Tkaczyk, S
    Woodbury, K
    Yarema, R
    Zimmerman, S
    Zimmerman, T
    Gay, C
    Huth, J
    Oliver, J
    Spiropulu, M
    Stroehmer, R
    Iwata, Y
    Ohmoto, T
    Ohsugi, T
    Barnett, B
    Skarha, J
    Snider, R
    Takashima, R
    Ely, R
    GarciaSciveres, M
    Haber, C
    Milgrome, O
    Lu, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 383 (01): : 13 - 20
  • [46] Operational experience with the CDF Run II silicon detector
    Eusebi, Ricardo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (01): : 50 - 53
  • [47] SPY: a monitoring system for the silicon vertex detector of CDF
    Bedeschi, F.
    Galeotti, S.
    Gherarducci, F.
    Mariotti, M.
    Morsani, F.
    Passuello, D.
    Tartarelli
    Grieco, G.M.
    Nelson, C.
    Tkaczyk, S.
    Haber, C.
    Ristori, L.
    Bailey, M.
    Sciacca, G.F.
    Turini, N.
    Cei, M.
    1998, (40):
  • [48] Operational experience with the CDF Run ll Silicon Detector
    Mondragon, Miguel N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3): : 571 - 572
  • [49] SVX II silicon vertex detector upgrade at CDF
    Antos, J.
    Chao, H.-Y.
    Cheng, M.-T.
    Chu, M.-L.
    Guo, R.-S.
    Ho, C.-L.
    Teng, P.-K.
    Wang, M.-J.
    Wu, S.-C.
    Yeh, G.P.
    Yeh, P.
    Blucher, E.
    Frisch, H.
    Sullivan, G.
    Barsotti, E.
    Cihangir, S.
    Nuclear Instruments & Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1995, 360 (1-2):
  • [50] Experience with parallel optical link for the CDF silicon detector
    Hou, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 511 (1-2): : 166 - 170