Mathematical Modeling of Fast and Accurate Coupled Electromagnetic-Thermal Analysis

被引:13
|
作者
Ryu, Jun-Yeol [1 ]
Hwang, Sung-Woo [1 ]
Chin, Jun-Woo [1 ]
Hwang, Yong-Suk [2 ]
Yoon, Sang Won [1 ]
Lim, Myung-Seop [1 ]
机构
[1] Hanyang Univ, Dept Automot Engn, Seoul 04763, South Korea
[2] MANDO Corp, Seongnam Si 13486, South Korea
基金
新加坡国家研究基金会;
关键词
Mathematical model; Electric variables; Computational modeling; Temperature distribution; Magnetic cores; Thermal analysis; Integrated circuit modeling; Coupled electromagnetic-thermal analysis; electric brake; lumped parameter magnetic circuit; lumped parameter thermal network; mathematical modeling; permanent magnet synchronous motor (PMSM); EFFICIENCY; MOTOR; PARAMETERS; DESIGN; TORQUE;
D O I
10.1109/TIA.2021.3086823
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This article proposes a fast and accurate coupled electromagnetic-thermal analysis method for a permanent magnet synchronous motor. In conventional design methods, the electric and thermal characteristics are calculated simultaneously using a finite element analysis (FEA). However, FEA requires considerable computational time. Therefore, in order to reduce the computational time, mathematical models of the electric parameters and characteristics were proposed as an alternative. Accordingly, the models of the electric parameter, such as d- and q-axis inductance and flux linkage, were obtained using a modified lumped parameter magnetic circuit containing a reluctance of an iron core. Furthermore, the models were fitted according to the formula type to consider nonlinearity according to variations in current and temperature. The electric parameters calculated by FEA were used for curve fitting. A greater number of FEA points were required to determine the effect of current and temperature on the electric parameters. Curve fitting using an appropriate formula type was performed considering the accuracy and minimum number of analysis points. Mathematical modeling of the electric characteristics, including efficiency and losses, was performed. The models of losses were coupled as heat sources to the lumped parameter thermal network, which is well known for its low computational time. The proposed coupled analysis method was applied to a reference motor; through this analysis, the electric characteristics and temperature distribution were calculated simultaneously, considering changes in losses and temperature distribution. The experimental validation was conducted with an acceptable error of 4.4%.
引用
收藏
页码:4636 / 4645
页数:10
相关论文
共 50 条
  • [31] Electromagnetic-Thermal Timesaving Coupling Analysis of a Water Cooling IPM Machine for Accurate Prediction Performance
    Liu, Chengsi
    Yu, Guodong
    Xu, Yongxiang
    Zoo, Jibin
    Xiao, Lijun
    2019 22ND INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2019), 2019, : 2688 - 2692
  • [32] Node-based smoothed radial point interpolation method for electromagnetic-thermal coupled analysis
    Zhou, Liming
    Ren, Shuhui
    Meng, Guangwei
    Ma, Zhichao
    APPLIED MATHEMATICAL MODELLING, 2020, 78 (78) : 841 - 862
  • [33] Coupled electromagnetic-thermal solution strategy for induction heating of ferromagnetic materials
    Fisk, Martin
    Ristinmaa, Matti
    Hultkrantz, Andreas
    Lindgren, Lars-Erik
    APPLIED MATHEMATICAL MODELLING, 2022, 111 : 818 - 835
  • [34] Development of Efficient Electromagnetic-Thermal Coupled Model of Electric Machines Based on Finite Element Analysis
    Jiang, Wenying
    Jahns, T. M.
    2013 IEEE INTERNATIONAL ELECTRIC MACHINES & DRIVES CONFERENCE (IEMDC), 2013, : 816 - 823
  • [35] An Electromagnetic-Thermal Modeling Method for the Joint Resistance of the CORC Cable
    Li, Chao
    Yang, Wenchao
    Cai, Ying
    Li, Bin
    Xin, Ying
    Yang, Jiabin
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (05) : 1 - 5
  • [36] Coupled Electromagnetic-Thermal Modelling of Dynamic Performance for Modular SPM Machines
    Zhang, Wei
    Li, Guang-Jin
    Zhu, Zi-Qiang
    Ren, Bo
    Chong, Yew Chuan
    ENERGIES, 2023, 16 (06)
  • [37] Coupled electromagnetic-thermal analysis of roadway inductive power transfer pads within a model pavement
    Amirpour, Maedeh
    Kim, Seho
    Battley, Matthew P.
    Kelly, Piaras
    Bickerton, Simon
    Covic, Grant
    APPLIED THERMAL ENGINEERING, 2021, 189
  • [38] Thermal Analysis of Giant Magnetostrictive Transducer Based on Stress-Independent Electromagnetic-Thermal Coupling Modeling
    Zhang, Zhihe
    Yang, Xin
    Chen, Yukai
    Zheng, Haobin
    IEEE SENSORS JOURNAL, 2024, 24 (22) : 37015 - 37030
  • [39] Aspects of Electromagnetic-Thermal Coupled Optimization of Asynchronous Machines for Traction Drives
    Buschbeck, J.
    Vogelsberger, M. A.
    Orellano, A.
    Schmidt, E.
    2014 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2014, : 2152 - 2157
  • [40] Modeling and Verification of Electromagnetic-Thermal Coupling for Electromagnetic Track Launch Considering the Dynamic Conductivity
    Yan, Rongge
    Jiang, Jinbo
    Yang, Qingxin
    An, Kang
    APPLIED SCIENCES-BASEL, 2023, 13 (15):