Intracochlear Recordings of Acoustically and Electrically Evoked Potentials in Nucleus Hybrid L24 Cochlear Implant Users and Their Relationship to Speech Perception

被引:24
|
作者
Kim, Jae-Ryong [1 ,2 ]
Tejani, Viral D. [1 ,3 ]
Abbas, Paul J. [1 ,3 ]
Brown, Carolyn J. [1 ,3 ]
机构
[1] Univ Iowa, Dept Commun Sci & Disorders, Iowa City, IA 52242 USA
[2] Inje Univ, Coll Med, Dept Otolaryngol Head & Neck Surg, Busan, South Korea
[3] Univ Iowa Hosp & Clin, Dept Otolaryngol Head & Neck Surg, Iowa City, IA 52242 USA
来源
FRONTIERS IN NEUROSCIENCE | 2017年 / 11卷
关键词
cochlear implant; auditory evoked potentials; electrocochleography; electrically evoked compound action potential; hybrid cochlear implant; neural response telemetry; HEARING PRESERVATION OUTCOMES; MULTICENTER CLINICAL-TRIAL; SPIRAL GANGLION-CELLS; SHORT ELECTRODE ARRAY; BRAIN-STEM RESPONSE; NERVE SURVIVAL; FUNDAMENTAL-FREQUENCY; WORD RECOGNITION; TEMPORAL CUES; RECIPIENTS;
D O I
10.3389/fnins.2017.00216
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The Hybrid cochlear implant (CI) has been developed for individuals with high frequency hearing loss who retain good low frequency hearing. Outcomes have been encouraging but individual variability is high; the health of the cochlea and the auditory nerve may be important factors driving outcomes. Electrically evoked compound action potentials (ECAPs) reflect the response of the auditory nerve to electrical stimulation while electrocochleography (ECochG) reflects the response of the cochlear hair cells and auditory nerve to acoustic stimulation. In this study both ECAPs and ECochG responses were recorded from Nucleus Hybrid L24 CI users. Correlations between these two measures of peripheral auditory function and speech perception are reported. This retrospective study includes data from 25 L24 CI users. ECAPs and ECochG responses were recorded from an intracochlear electrode using stimuli presented at or near maximum acceptable loudness levels. Speech perception was assessed using Consonant-Nucleus-Consonant (CNC) word lists presented in quiet and AzBio sentences presented at a +5 dB signal-to-noise ratio in both the combined acoustic and electric (A+E) and electric (E) alone listening modes. Acoustic gain was calculated by subtracting these two scores. Correlations between these physiologic and speech perception measures were then computed. ECAP amplitudes recorded from the most apical electrode were significantly correlated with CNC scores measured in the E alone (r = 0.56) and A+E conditions (r = 0.64), but not with performance on the AzBio test. ECochG responses recorded using the most apical electrode in the intracochlear array but evoked using a 500 Hz tone burst were not correlated with either the scores on the CNC or AzBio tests. However, ECochG amplitude was correlated with a composite metric relating the additional benefit of acoustic gain in noise relative to quiet conditions (r = 0.67). Both measures can be recorded from Hybrid L24 CI users and both ECAP and ECochG measures may result in more complete characterization of speech perception outcomes than either measure alone.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Speech Perception Performance in Cochlear Implant Recipients Correlates to the Number and Synchrony of Excited Auditory Nerve Fibers Derived From Electrically Evoked Compound Action Potentials
    Dong, Yu
    Briaire, Jeroen J.
    Stronks, H. Christiaan
    Frijns, Johan H. M.
    EAR AND HEARING, 2023, 44 (02): : 276 - 286
  • [42] Assessing the Relationship Between the Electrically Evoked Compound Action Potential and Speech Recognition Abilities in Bilateral Cochlear Implant Recipients
    Schvartz-Leyzac, Kara C.
    Pfingst, Bryan E.
    EAR AND HEARING, 2018, 39 (02): : 344 - 358
  • [43] INTRAOPERATIVE AND POSTOPERATIVE ELECTRICALLY-EVOKED AUDITORY BRAIN-STEM RESPONSES IN NUCLEUS COCHLEAR IMPLANT USERS - IMPLICATIONS FOR THE FITTING PROCESS
    BROWN, CJ
    ABBAS, PJ
    FRYAUFBERTSCHY, H
    KELSAY, D
    GANTZ, BJ
    EAR AND HEARING, 1994, 15 (02): : 168 - 176
  • [44] Conversion from the SPEAK to the ACE strategy in children using the Nucleus 24 cochlear implant system: Speech perception and speech production outcomes
    Psarros, CE
    Plant, KL
    Lee, K
    Decker, JA
    Whitford, LA
    Cowan, RSC
    EAR AND HEARING, 2002, 23 (01): : 18S - 27S
  • [45] Clinically recorded cortical auditory evoked potentials from paediatric cochlear implant users fitted with electrically elicited stapedius reflex thresholds
    Kosaner, Julie
    Van Dun, Bram
    Yigit, Ozgur
    Gultekin, Muammer
    Bayguzina, Svetlana
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2018, 108 : 100 - 112
  • [46] SpeedCAP: An Efficient Method for Estimating Neural Activation Patterns Using Electrically Evoked Compound Action-Potentials in Cochlear Implant Users
    Garcia, Charlotte
    Deeks, John M.
    Goehring, Tobias
    Borsetto, Daniele
    Bance, Manohar
    Carlyon, Robert P.
    EAR AND HEARING, 2023, 44 (03): : 627 - 640
  • [47] The Relationship Between the Electrically Evoked Stapedius Reflex Threshold and Stimulus Burst Duration in Pediatric Cochlear Implant Users: Preliminary Data
    Walkowiak, Adam
    Kontides, Alejandra
    Takanen, Marko
    Obrycka, Anita
    Skarzynski, Piotr
    Skarzynski, Henryk
    Lorens, Artur
    OTOLOGY & NEUROTOLOGY, 2025, 46 (01) : e21 - e27
  • [48] Electrically evoked whole nerve action potentials in ineraid cochlear implant users: Responses to different stimulating electrode configurations and comparison to psychophysical responses
    Brown, CJ
    Abbas, PJ
    Borland, J
    Bertschy, MR
    JOURNAL OF SPEECH AND HEARING RESEARCH, 1996, 39 (03): : 453 - 467
  • [49] Modeling the relationship between psychophysical perception and electrically evoked compound action potential threshold in young cochlear implant recipients: clinical implications for implant fitting
    Thai-Van, H
    Truy, E
    Charasse, B
    Boutitie, F
    Chanal, JM
    Cochard, N
    Piron, JP
    Ribas, S
    Deguine, O
    Fraysse, B
    Mondain, M
    Uziel, A
    Collet, L
    CLINICAL NEUROPHYSIOLOGY, 2004, 115 (12) : 2811 - 2824
  • [50] Comparison of speech recognition with different speech coding strategies (SPEAK, CIS, and ACE) and their relationship to telemetric measures of compound action potentials in the nucleus CI 24M cochlear implant system
    Kiefer, J
    Hohl, S
    Stürzebecher, E
    Pfennigdorff, T
    Gstöettner, W
    AUDIOLOGY, 2001, 40 (01): : 32 - 42