Load distribution of the hand during cylinder grip analyzed by Manugraphy

被引:19
|
作者
Muehldorfer-Fodor, Marion [1 ]
Ziegler, Steffen [1 ]
Harms, Christoph [2 ]
Neumann, Julia [2 ]
Kundt, Guenther [3 ]
Mittlmeier, Thomas [2 ]
Prommersberger, Karl Josef [1 ]
机构
[1] Rhon Klinikum AG, Clin Hand Surg, Salzburger Leite 1, D-97616 Bad Neustadt an der Saale, Germany
[2] Univ Rostock, Med Ctr, Dept Trauma Hand & Reconstruct Surg, Rostock, Germany
[3] Univ Rostock, Inst Biostat & Informat Med & Ageing Res, Rostock, Germany
关键词
Cylinder grip; Hand dominance; Handle size; Load distribution; Manugraphy system; PINCH STRENGTH; FINGER FORCES; CYLINDRICAL HANDLE; WRIST POSITION; SIZE; SENSOR;
D O I
10.1016/j.jht.2016.10.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study Design: Clinical measurement and basic research. Introduction: Manugraphy allows assessing dynamically all forces applied perpendicular to a cylinder surface by the whole contact area of the hand with a high spatial resolution. Purpose of the Study: To identify the physiological load distribution of the whole contact area of the hand during cylinder grip. Methods: A sample of 152 healthy volunteers performed grip force tests with 3 cylinder sizes of the Manugraphy system (novel, Munich, Germany) on 3 different days. The whole contact area of the hand was sectioned into 7 anatomic areas, and the percent contribution of each area in relation to the total load applied was calculated. The load distribution of the dominant and nondominant hands and with different cylinder sizes was compared. Furthermore, the load distribution between the finger phalanges of each finger was analyzed. Results: The results for the dominant and nondominant hands were in all 7 areas of the hand similar with the percent contribution differing within a range of 1%-4% (P > .138). Load distribution changed significantly with different cylinder sizes: all 7 areas differed between 1% and 7% with P < .001, most pronounced for the thumb. The load distribution of the phalanges showed that the contribution of the distal phalanges increased with ascending cylinder size, whereas the contribution of the proximal phalanges decreased. The interindividual variability of the load distribution pattern was noticeable. Discussion: For the clinical practice, Manugraphy might be a useful supplement to traditional grip force measurement for identifying the individual characteristics of a patient's dysfunction and monitoring the progress of hand rehabilitation. Conclusions: There is no universal or typical load distribution pattern of the hand but only an individual pattern. To evaluate a compromised hand, it is permissible to compare it with the healthy opposite hand as a reference. Several cylinder sizes should be used for load distribution testing. Using smaller handles in the daily life can help to compensate impairment of the thumb and fingertips. Level of Evidence: 2. (C) 2016 Hanley & Belfus, an imprint of Elsevier Inc. All rights reserved.
引用
收藏
页码:529 / 537
页数:9
相关论文
共 50 条
  • [1] Influence of Maximal or Submaximal Effort on the Load Distribution of the Hand Analyzed by Manugraphy
    Muehldorfer-Fodor, Marion
    Cenik, Eren
    Hahn, Peter
    Mittlmeier, Thomas
    van Schoonhoven, Joerg
    Prommersberger, Karl Josef
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2018, 43 (10): : 948.e1 - 948.e9
  • [2] Prospective analysis of grip strength and load distribution after surgical treatment of common diseases of the hand with novel’s manugraphy® system
    Jasmin S. Grüner
    Aijia Cai
    Isabel Pingel
    Raymund E. Horch
    Justus P. Beier
    Andreas Arkudas
    [J]. Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 6477 - 6485
  • [3] Prospective analysis of grip strength and load distribution after surgical treatment of common diseases of the hand with novel's manugraphy® system
    Gruener, Jasmin S.
    Cai, Aijia
    Pingel, Isabel
    Horch, Raymund E.
    Beier, Justus P.
    Arkudas, Andreas
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (10) : 6477 - 6485
  • [4] Load distribution and forearm muscle activity during cylinder grip at various grip strength values
    Mukaiyama, K.
    Irie, K.
    Takeda, M.
    Yamashita, R.
    Uemura, S.
    Kanazawa, S.
    Nagai-Tanima, M.
    Aoyama, T.
    [J]. HAND SURGERY & REHABILITATION, 2022, 41 (02): : 176 - 182
  • [5] Parameters influencing hand grip strength measured with the manugraphy system
    Alice Wichelhaus
    Christoph Harms
    Julia Neumann
    Steffen Ziegler
    Günther Kundt
    Karl Josef Prommersberger
    Thomas Mittlmeier
    Marion Mühldorfer-Fodor
    [J]. BMC Musculoskeletal Disorders, 19
  • [6] Parameters influencing hand grip strength measured with the manugraphy system
    Wichelhaus, Alice
    Harms, Christoph
    Neumann, Julia
    Ziegler, Steffen
    Kundt, Guenther
    Prommersberger, Karl Josef
    Mittlmeier, Thomas
    Muehldorfer-Fodor, Marion
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [7] Motion Coordination Patterns During Cylinder Grip Analyzed With a Sensor Glove
    Guelke, Joachim
    Wachter, Nikolaus J.
    Geyer, Thomas
    Schoell, Hendrik
    Md, Goran Apic
    Mentzel, Martin
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (05): : 797 - 806
  • [8] Grip force monitoring on the hand: Manugraphy system versus Jamar dynamometer
    Muehldorfer-Fodor, Marion
    Ziegler, Steffen
    Harms, Christoph
    Neumann, Julia
    Cristalli, Alessandra
    Kalpen, Axel
    Kundt, Guenther
    Mittlmeier, Thomas
    Prommersberger, K. J.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2014, 134 (08) : 1179 - 1188
  • [9] Grip force monitoring on the hand: Manugraphy system versus Jamar dynamometer
    Marion Mühldorfer-Fodor
    Steffen Ziegler
    Christoph Harms
    Julia Neumann
    Alessandra Cristalli
    Axel Kalpen
    Günther Kundt
    Thomas Mittlmeier
    K. J. Prommersberger
    [J]. Archives of Orthopaedic and Trauma Surgery, 2014, 134 : 1179 - 1188
  • [10] Dynamic aspects during the cylinder grip - flexion sequence of the finger joints analyzed using a sensor glove
    Guelke, J.
    Gulkin, D.
    Wachter, N.
    Knoeferl, M.
    Bartl, C.
    Mentzel, M.
    [J]. JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2013, 38E (02) : 178 - 182