Diagnostic accuracy of computer-assisted sperm motion analysis

被引:36
|
作者
De Geyter, C [1 ]
De Geyter, M [1 ]
Koppers, B [1 ]
Nieschlag, E [1 ]
机构
[1] Univ Munster, Inst Reprod Med, D-48129 Munster, Germany
关键词
computer-assisted sperm motion analysis; hyperactivation; Hamilton Thorne; in-vitro fertilization; male infertility;
D O I
10.1093/humrep/13.9.2512
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
One retrospective and two prospective studies were conducted among 218 couples treated with in-vitro fertilization (IVF) to establish the reproducibility and diagnostic accuracy of computer-assisted sperm analysis (CASA) with swim-up spermatozoa for the prediction of the fertilization rate of oocytes in vitro, Based on the results of a preliminary retrospective analysis in 49 patients, the 'curvilinear velocity' (VCL) was chosen as the most distinctive motion parameter of sperm function and the median was used to represent the entire sperm population, The number of inseminated motile spermatozoa was then adjusted to median VCL during two subsequent prospective studies with clinical IVF, Whereas in the first prospective study (90 couples) the threshold values of VCL with regard to the number of spermatozoa inseminated were based on the results of the preliminary retrospective study (49 couples), in the second prospective study (79 couples) the settings were based on the results of the first prospective study. The reproducibility of CASA was tested by analysing the motion characteristics of spermatozoa at different intervals after termination of swim-up, by repeated analysis of the same video-recording of the incubated spermatozoa by different observers, and by the repeated video-recording of the freshly prepared sperm samples and analysis of both video-recordings by the same observer. Under these conditions the frequency of disagreement between two measurements varied between 2.0 and 8.2%, In both prospective studies the sensitivity of CASA for the prediction of fertilization was high (74.0%), whereas the specificity was low (40.0%), In contrast to successful fertilization, unsuccessful fertilization of oocytes in vitro could not be predicted reliably with CASA, However, the pregnancy rate per cycle among patients,vith predicted low fertilization rates was significantly lower (5.3%) than in couples with high predicted fertilization rates (24.3%, P < 0.001). Therefore, CASA of washed spermatozoa may still help to identify couples who would benefit more from intracytoplasmic sperm injection (ICSI) than from IVF, A definite threshold level could not be identified for any of the motion parameters to distinguish the motion characteristics of fertilizing and non-fertilizing spermatozoa, Using various algorithms for hyperactivated motility, the percentage of hyperactivated spermatozoa was significantly higher among the successfully fertilizing patients than among the nonfertilizing group. However, the absolute number of hyperactivated spermatozoa added to the oocytes was higher in non-fertilizing couples, Therefore, the lack of fertilization in some patients may be caused by a generalized defect in sperm function rather than by insufficient hyperactivation.
引用
收藏
页码:2512 / 2520
页数:9
相关论文
共 50 条
  • [41] Quantification of bull sperm characteristics measured by computer-assisted sperm analysis (CASA) and the relationship to fertility
    Farrell, PB
    Presicce, GA
    Brockett, CC
    Foote, RH
    THERIOGENOLOGY, 1998, 49 (04) : 871 - 879
  • [42] Sperm Collection and Computer-Assisted Sperm Analysis in the Teleost Model Japanese Medaka (Oryzias latipes)
    Closs, Lauren
    Sayyari, Amin
    Fontaine, Romain
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (188):
  • [43] COMPUTER-ASSISTED DIAGNOSIS AND COMPUTER CONSULTATION IN NEUROLOGY - PRELIMINARY TESTING OF DIAGNOSTIC-ACCURACY FOR THE NEUROLOGIST SYSTEM
    CATANZARITE, VA
    GREENBURG, AG
    BREMERMANN, HJ
    INTERNATIONAL JOURNAL OF NEUROSCIENCE, 1981, 13 (01) : 43 - 54
  • [44] Accuracy of computer-assisted semen analysis in prefreeze and post-thaw specimens with high and low sperm counts and motility
    Sidhu, RS
    Sharma, RK
    Lee, JC
    Agarwal, A
    UROLOGY, 1998, 51 (02) : 306 - 312
  • [45] Improvement of the diagnostic accuracy in computer-assisted differential diagnosis for wide QRS premature complexes
    Katoh, T
    Yodogawa, K
    Ohno, T
    Hayakawa, H
    CIRCULATION JOURNAL, 2003, 67 (12) : 1036 - 1040
  • [46] Registration accuracy in computer-assisted pelvic surgery
    Docquier, P. L.
    Paul, L.
    Cartiaux, O.
    Banse, X.
    COMPUTER AIDED SURGERY, 2009, 14 (1-3) : 37 - 44
  • [47] Diagnostic accuracy of commercial system for computer-assisted detection (CADx) as an adjunct to interpretation of mammograms
    Menna, S
    Di Virgilio, MR
    Burke, P
    Frigerio, A
    Boglione, E
    Ciccarelli, G
    Di Filippo, S
    Garretti, L
    RADIOLOGIA MEDICA, 2005, 110 (04): : 334 - 340
  • [48] THE ACCURACY OF COMPUTER-ASSISTED FEEDBACK AND STUDENTS' RESPONSES TO IT
    Lavolette, Elizabeth
    Polio, Charlene
    Kahng, Jimin
    LANGUAGE LEARNING & TECHNOLOGY, 2015, 19 (02): : 50 - 68
  • [49] Computer-assisted sperm head morphometry analysis (ASMA) of cryopreserved ram spermatozoa
    Gravance, CG
    Champion, ZJ
    Casey, PJ
    THERIOGENOLOGY, 1998, 49 (06) : 1219 - 1230
  • [50] Repeatability and variance analysis on multiple computer-assisted (IVOS*) sperm morphology readings
    Coetzee, K
    Kruger, TF
    Lombard, CJ
    ANDROLOGIA, 1999, 31 (03) : 163 - 168