A new EPMA method for fast trace element analysis in simple matrices

被引:92
|
作者
Donovan, John J. [1 ]
Singer, Jared W. [2 ]
Armstrong, John T. [3 ]
机构
[1] Univ Oregon, CAMCOR, Eugene, OR 97403 USA
[2] Rensselaer Polytech Inst, Troy, NY 12180 USA
[3] Carnegie Inst Sci, Geophys Lab, 5251 Broad Branch Rd NW, Washington, DC 20015 USA
关键词
EPMA; quantitative analysis; microanalysis; trace elements; sensitivity; accuracy; X-ray mapping;
D O I
10.2138/am-2016-5628
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
It is well known that trace element sensitivity in electron probe microanalysis (EPMA) is limited by intrinsic random variation in the X-ray continuum background and weak signals at low concentrations. The continuum portion of the background is produced by deceleration of the electron beam by the Coulombic field of the specimen atoms. In addition to the continuum, the background also includes interferences from secondary emission lines, "holes" in the continuum from secondary Bragg diffraction, non-linear curvature of the wavelength-dispersive spectrometer (WDS) continuum and other background artifacts. Typically, the background must be characterized with sufficient precision (along with the peak intensity of the emission line of interest, to obtain the net intensity for subsequent quantification), to attain reasonable accuracy for quantification of the elements of interest. Traditionally we characterize these background intensities by measuring on either side of the emission line and interpolate the intensity underneath the peak to obtain the net intensity. Instead, by applying the mean atomic number (MAN) background calibration curve method proposed in this paper for the background intensity correction, such background measurement artifacts are avoided through identification of outliers within a set of standards. We divide the analytical uncertainty of the MAN background calibration between precision errors and accuracy errors. The precision errors of the MAN background calibration are smaller than direct background measurement, if the mean atomic number of the sample matrix is precisely known. For a simple matrix and a suitable blank standard, a high-precision blank correction can offset the accuracy component of the MAN uncertainty. Use of the blank-corrected-MAN background calibration can further improve our measurement precision for trace elements compared to traditional off-peak measurements because the background determination is not limited by continuum X-ray counting statistics. For trace element mapping of a simple matrix, the background variance due to major element heterogeneity is exceedingly small and high-precision two-dimensional background correction is possible.
引用
收藏
页码:1839 / 1853
页数:15
相关论文
共 50 条
  • [41] Trace element analysis by multiple gamma ray detection method
    Toh, Y
    Oshima, M
    Matsumoto, R
    Gharaie, MHM
    Hatsukawa, Y
    Shinohara, N
    Kimura, A
    Goto, J
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2003, 67 (18) : A483 - A483
  • [42] TRACE-ELEMENT ANALYSIS BY USING THE DIRECT CPAA METHOD
    TAKACS, S
    DITROI, F
    MAHUNKA, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1985, 10-1 (MAY): : 1051 - 1053
  • [43] Trace element mapping of pyrite from Archean gold deposits - A comparison between PIXE and EPMA
    Agangi, A.
    Przybylowicz, W.
    Hofmann, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 348 : 302 - 306
  • [44] Trace element characterization of medieval and post-medieval glass objects by means of INAA and EPMA
    J. Kunicki-Goldfinger
    E. Pańczyk
    P. Dierżanowski
    L. Waliś
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 278 : 307 - 311
  • [45] Trace element characterization of medieval and post-medieval glass objects by means of INAA and EPMA
    Kunicki-Goldfinger, J.
    Panczyk, E.
    Dierzanowski, P.
    Walis, L.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 278 (02) : 307 - 311
  • [46] New formulation of quasi-conforming method: A simple membrane element for analysis of planar problems
    Wang, Changsheng
    Zhang, Xiangkui
    Hu, Ping
    EUROPEAN JOURNAL OF MECHANICS A-SOLIDS, 2016, 60 : 122 - 133
  • [47] TRACE-ELEMENT ANALYSIS OF UREILITES - NEW CONSTRAINTS ON THEIR PETROGENESIS
    SPITZ, AH
    BOYNTON, WV
    GEOCHIMICA ET COSMOCHIMICA ACTA, 1991, 55 (11) : 3417 - 3430
  • [48] PIXE, a new technique for the trace element analysis of high explosives
    Lane, DW
    Wicks, DC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 161 : 792 - 796
  • [49] NEW TRACE ANALYSIS METHOD FOR DETERMINATION OF THIOUREA
    SOHR, H
    WIENHOLD, K
    ANALYTICA CHIMICA ACTA, 1976, 83 (MAY) : 415 - 419
  • [50] Trace element analysis with the electron microprobe:: New data and perspectives
    Fialin, M
    Rémy, H
    Richard, C
    Wagner, C
    AMERICAN MINERALOGIST, 1999, 84 (1-2) : 70 - 77