Stress/Rest 99mTc-MIBI SPECT and 123I-BMIPP scintigraphy for indication of surgery with coronary artery to pulmonary artery fistula

被引:15
|
作者
Sato, F
Koishizawa, T
机构
[1] Univ Tsukuba, Inst Clin Med, Dept Surg, Tsukuba, Ibaraki 3058577, Japan
[2] Tsukuba Mem Hosp, Dept Cardiovasc Surg, Ibaraki, Japan
关键词
coronary artery to pulmonary artery fistula; aneurysm; Tc-99m-MIBI SPECT; I-123-BMIPP; scintigraphy;
D O I
10.1536/ihj.46.355
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A 45-year old man was admitted to our hospital with chest pain occurring suddenly upon exercise and disappearing with test within several minutes. A continuous murmor was heard at the Upper sternum border. Conventional electrocardiography showed no evidence of myocardial ischemia. Coronary angiography and cardiac catheterization demonstrated a fistula originating from the left coronary artery to the pulmonary artery with an aneurtsm 2 cm in size, and Qp/Qs 1.08. Treadmill exercise testing showed no ST-T chance at the maximum heart rate of 160 beats/min. Stress/Rest (99m)Technetium-MIBI single-photon emission computed tomography (SPECT) and (123)1-15-(p-iodo-pheny1)-3,R,S-methylpentadecanoic acid (BMIPP) scintigraphy were performed to evaluate myocardial ischemia and ischemia was identified at the perfusion area of the left anterior descending artery. From these results, the patient was diagnosed as having a coronary artery to pulmonary artery fistula with myocardial ischemia. Consequently, surgical treatment was chosen Under cardiopulmonary bypass. The determination of a surgical indication Using stress/rest Tc-99m-MIBI SPECT and BMIPP scintigraphy is useful in cases showing normal TMT, such Lis this case.
引用
收藏
页码:355 / 361
页数:7
相关论文
共 50 条
  • [41] 99mTc-tekhnetril (99mTc-MiBi) labeled with technetium-99m from extraction and sorption generators in scintigraphic diagnostics of coronary artery disease
    Lishmanov, YB
    Chernov, VI
    Vesnina, ZV
    Krivonogov, NG
    Skuridin, VS
    Garganeeva, AA
    RADIOCHEMISTRY, 1997, 39 (05) : 404 - 409
  • [42] Ability of 201Tl and 123I-BMIPP mismatch to diagnose myocardial ischemia in patients with suspected coronary artery disease
    Ayako Nakamura
    Mitsuru Momose
    Chisato Kondo
    Takatomo Nakajima
    Kiyoko Kusakabe
    Nobuhisa Hagiwara
    Annals of Nuclear Medicine, 2009, 23 : 793 - 798
  • [43] Evaluation of 99mTc-MIBI myocardial perfusion imaging with intravenous infusion of adenosine triphosphate in diagnosis of coronary artery disease
    He, Q
    Yao, ZM
    Yu, X
    Qu, WY
    Sun, FC
    Ji, F
    Xu, F
    Qian, YJ
    CHINESE MEDICAL JOURNAL, 2002, 115 (11) : 1603 - 1607
  • [44] Ability of 201Tl and 123I-BMIPP mismatch to diagnose myocardial ischemia in patients with suspected coronary artery disease
    Nakamura, Ayako
    Momose, Mitsuru
    Kondo, Chisato
    Nakajima, Takatomo
    Kusakabe, Kiyoko
    Hagiwara, Nobuhisa
    ANNALS OF NUCLEAR MEDICINE, 2009, 23 (09) : 793 - 798
  • [45] Value of quantitative I-123 BMIPP SPECT for therapeutic strategy in unstable coronary artery disease.
    Nishimura, S
    Ohta, Y
    Katoh, K
    Tamaki, T
    Yumoto, K
    Odaka, K
    Yamauchi, Y
    Yoshino, A
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 360 - 360
  • [46] The effect of scatter and cross-talk correction for one-day acquisition of 123I-BMIPP and 99mTc-tetrofosmin myocardial SPECT.
    Kaneta, T
    Kurihara, H
    Maruoka, S
    Takahashi, S
    Yamada, S
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 202P - 203P
  • [47] Comparative study of single-injection, single-acquisition 99mTc-MIBI gated SPET and stress-rest perfusion SPET for the evaluation of myocardial viability after bypass surgery in coronary artery disease
    Seok Nam Yoon
    Dong Soo Lee
    June-Key Chung
    Myung Chul Lee
    European Journal of Nuclear Medicine, 2000, 27 : 1747 - 1753
  • [48] Comparative study of single-injection, single-acquisition 99mTc-MIBI gated SPET and stress-rest perfusion SPET for the evaluation of myocardial viability after bypass surgery in coronary artery disease
    Yoon, SN
    Lee, DS
    Chung, JK
    Lee, MC
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (12) : 1747 - 1753
  • [49] 123I-BMIPP and 99mTc-TF discordance on myocardial scintigraphy and it’s correlation with functional recovery following acute myocardial infarction: role of conventional echocardiography
    Shankar K. Biswas
    Masayoshi Sarai
    Hiroshi Toyama
    Akira Yamada
    Sadako Motoyama
    Hiroto Harigaya
    Tomonori Hara
    Masatsugu Iwase
    Hitoshi Hishida
    Yukio Ozaki
    The International Journal of Cardiovascular Imaging, 2009, 25 : 765 - 775
  • [50] 123I-BMIPP and 99mTc-TF discordance on myocardial scintigraphy and it's correlation with functional recovery following acute myocardial infarction: role of conventional echocardiography
    Biswas, Shankar K.
    Sarai, Masayoshi
    Toyama, Hiroshi
    Yamada, Akira
    Motoyama, Sadako
    Harigaya, Hiroto
    Hara, Tomonori
    Iwase, Masatsugu
    Hishida, Hitoshi
    Ozaki, Yukio
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (08): : 765 - 775