Lumbar total disc replacement from an extreme lateral approach clinical experience with a minimum of 2 years' follow-up Clinical article

被引:66
|
作者
Pimenta, Luiz [1 ,2 ]
Oliveira, Leonardo [1 ]
Schaffa, Thomas [1 ]
Coutinho, Etevaldo [1 ]
Marchi, Luis [1 ]
机构
[1] Inst Patol Coluna, BR-04101000 Sao Paulo, Brazil
[2] Univ Calif San Diego, Dept Neurosurg, San Diego, CA 92103 USA
关键词
arthroplasty; total disc replacement; lateral approach; extreme lateral interbody fusion; minimally invasive surgery; INVESTIGATIONAL DEVICE EXEMPTION; CHARITE(TM) ARTIFICIAL DISC; INTERVERTEBRAL DISC; INTERBODY FUSION; MULTICENTER; COMPLICATIONS; ARTHROPLASTY; OUTCOMES; PRODISC; STRATEGIES;
D O I
10.3171/2010.9.SPINE09865
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object Current lumbar total disc replacement (TDR) devices require an anterior approach for implantation This approach has inherent limitations including risks to abdominal structures and the need for resection of the an tenor longitudinal ligament (ALL) Placement of a TDR device from a true lateral (extreme lateral interbody fusion [XLIF]) approach is thought to offer a less invasive option to access the disc space preserving the stabilizing ligaments and avoiding scarring of anterior vasculature In this study the authors attempted to quantify the clinical and radiographic outcomes of a lateral approach to lumbar TDR from a prospective single-center experience Methods A TDR device designed for implantation through a true lateral retroperitoneal transpsoas approach (XLIF) was implanted in 36 patients with discography-confirmed 1 or 2 level degenerative disc disease Clinical (pain and function) and radiographic (range of motion [ROM]) data were prospectively collected preoperatively, postoperatively and serially for a minimum of 24 months follow-up Results Thirty six surgeries were performed in 16 men and 20 women (mean age 42 6 years) Surgeries included 15 single-level TDR procedures at L3-4 or L4-5, three 2-level TDR procedures spanning L3-4 and L4-5, and 18 hybrid procedures (anterior lumbar interbody fusion [ALIF]) at L5-S1 and TDR at L4-5 [17] or L3-4 [1]) Operative time averaged 130 minutes with an average blood loss of 60 ml and no intraoperative complications Postoperative radiographs showed good device placement All patients were walking within 12 hours of surgery and all but 9 were discharged the next day (7 of 9 had hybrid TDR/ALIF procedures) Five patients (13 8%) had psoas weakness and 3 (8 3%) had anterior thigh numbness postoperatively both resolving within 2 weeks One patient (2 8%) demonstrated weakness of the leg ipsilateral to the approach side which lasted through the 3 month visit but was resolved by the 6 month visit One patient (2 8%) was found to have hypertrophy of the quadriceps contralateral to the approach side at the 12 month visit, which was resolved by the 2-year visit Four patients (11%) had postoperative facet joint pain, all in hybrid cases All patients were 2 years or more postsurgery as of this writing, although 3 were lost to follow-up between the 1 and 2-year visits In 2 cases (5 6%) removal of the TDR device and revision to fusion were required due to unresolved pain At 2 years' follow-up the average visual analog scale and Oswestry Disability Index scores had improved 69 6% and 61 4%, respectively and ROM averaged 8 6 degrees, well within physiological norms Conclusions Long term results of a laterally placed TDR device demonstrate maintenance of pain relief and functional improvement The benefits of this technique-minimal morbidity, avoiding mobilization of the great vessels preserving the ALL biomechanically stable orientation and broader revision options-suggest a promising new direction for TDR procedures (DOI 10 3171/2010 9 SPINE09865)
引用
收藏
页码:38 / 45
页数:8
相关论文
共 50 条
  • [41] Results of disc prosthesis after a minimum follow-up period of 2 years
    Cinotti, G
    David, T
    Postacchini, F
    [J]. SPINE, 1996, 21 (08) : 995 - 1000
  • [42] Clinical Outcomes of Nucleoplasty: Prospective Cohort Study with Minimum of 2 Years Follow-up
    Boey, J.
    Tow, B.
    Yeo, W.
    Tan, S. B.
    [J]. III WORLD CONGRESS OF MINIMALLY INVASIVE SPINE SURGERY AND TECHNIQUES - 4TH CONGRESS OF THE ASIA PACIFIC INITIATIVE ON REPRODUCTIONS, THE 30TH ANNUAL MEETING OF JAPAN SOCIETY OF FERTILIZATION AND IMPLANTATION - 3RD BIENNAL MEETING OF THE ASIA CORNEA, 2013, : 23 - 25
  • [43] Clinical Outcome of Monosegmental Total Disc Replacement for Lumbar Disc Disease with Ball-and-Socket Prosthesis (Maverick): Prospective Study with Four-Year Follow-up
    Van de Kelft, Erik
    Verguts, Leo
    [J]. WORLD NEUROSURGERY, 2012, 78 (3-4) : 355 - 363
  • [44] Clinical results of alumina medial pivot total knee arthroplasty at a minimum follow-up of 10 years
    Nakamura, Suguru
    Minoda, Yukihide
    Nakagawa, Shigeru
    Kadoya, Yoshinori
    Takemura, Susumu
    Kobayashi, Akio
    Mizokawa, Shigekazu
    Ohta, Yoichi
    Takahashi, Sinji
    Yamamura, Kazumasa
    Nakamura, Hiroaki
    [J]. KNEE, 2017, 24 (02): : 434 - 438
  • [45] An 11-year minimum follow-up of the Charite III lumbar disc replacement for the treatment of symptomatic degenerative disc disease
    Lu, Shi-bao
    Hai, Yong
    Kong, Chao
    Wang, Qing-yi
    Su, Qingjun
    Zang, Lei
    Kang, Nan
    Meng, Xiang-long
    Wang, Yu
    [J]. EUROPEAN SPINE JOURNAL, 2015, 24 (09) : 2056 - 2064
  • [46] Single and Multilevel Lumbar Total Disc Replacement Adjacent to L5-S1 ALIF (Lumbar Hybrid): 6 Years of Follow-up
    Cuellar, Jason M.
    Rasouli, Alexandre
    Lanman, Todd H.
    Kanim, Lea
    Delamarter, Rick
    [J]. INTERNATIONAL JOURNAL OF SPINE SURGERY, 2021, 15 (05): : 971 - 977
  • [47] Results and complications after 2-level axial lumbar interbody fusion with a minimum 2-year follow-up Clinical article
    Marchi, Luis
    Oliveira, Leonardo
    Coutinho, Etevaldo
    Pimenta, Luiz
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2012, 17 (03) : 187 - 192
  • [48] Clinical Results of Lateral Unicompartmental Knee Arthroplasty: Minimum 2-Year Follow-up
    Kim, Kyung Tae
    Lee, Song
    Kim, Jeehyoung
    Kim, Jin Woo
    Kang, Min Su
    [J]. CLINICS IN ORTHOPEDIC SURGERY, 2016, 8 (04) : 386 - 392
  • [49] An 11-year minimum follow-up of the Charite III lumbar disc replacement for the treatment of symptomatic degenerative disc disease
    Shi-bao Lu
    Yong Hai
    Chao Kong
    Qing-yi Wang
    Qingjun Su
    Lei Zang
    Nan Kang
    Xiang-long Meng
    Yu Wang
    [J]. European Spine Journal, 2015, 24 : 2056 - 2064
  • [50] Differences between soft-disc herniation and spondylosis in cervical arthroplasty: CT-documented heterotopic ossification with minimum 2 years of follow-up Clinical article
    Wu, Jau-Ching
    Huang, Wen-Cheng
    Tu, Tsung-Hsi
    Tsai, Hsiao-Wen
    Ko, Chin-Chu
    Wu, Ching-Lan
    Cheng, Henrich
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2012, 16 (02) : 163 - 171