AUGMENTATION OF THE ATROPHIC MAXILLARY SINUS FLOOR: GRAFT STIFFNESS, IMPLANT SHAPE AND LENGTH

被引:0
|
作者
La Barbera, L. [1 ]
Corbella, S. [2 ,3 ,4 ]
Taschieri, S. [2 ,3 ,4 ]
Galbusera, F. [5 ]
Gianni, A. B. [2 ,6 ]
Francetti, L. [2 ,3 ,7 ]
机构
[1] Politecn Milan, Lab Biol Struct Mech, Dept Chem Mat & Chem Engn Giulio Natta, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
[2] Univ Milan, Dept Biomed Surg & Dent Sci, Milan, Italy
[3] IRCCS Ist Ortoped Galeazzi, Dent Clin, Milan, Italy
[4] IM Sechenov First Moscow State Med Univ, Inst Dent, Moscow, Russia
[5] IRCCS Ist Ortoped Galeazzi, Milan, Italy
[6] Fdn IRCCS Ca Granda Osped Maggiore Policlin Milan, Maxillofacial & Dent Unit, Milan, Italy
[7] Univ Milan, Fac Med, Odontostomatol Clin, Milan, Italy
关键词
sinus atrophy; bone graft; implant design; finite element; FINITE-ELEMENT-ANALYSIS; POSTERIOR MAXILLA; STABILITY; DESIGNS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study investigates the characteristics of load transmission to bone of alternative treatments for posterior maxilla edentulism with relatively limited available bone volume. Implant shape (conical and cylindrical), augmentation technique and the effect of bone-graft stiffness were taken into consideration. The finite element models of the atrophic sinus implanted with short implant were compared to two grafted-sinus models implanted with longer implants, engaged bicortically. Bone-graft stiffness was varied to describe different stages of graft-maturation (from short-term to long-term). Stress and load distributions due to axial and bending loads were compared on the bony structures. In the short-term, axial force is supported almost equally by the cortical layers and the trabecular core, while a bending load is mainly supported by the crestal cortical layer and secondarily by the cortical floor, the bone-graft supported a negligible load. Bicortical engagement produces higher load transfer to the cortical floor under axial load. In the long-term, as the stiffness of the bone-graft increases, the load is transferred progressively towards the grafted region, progressively unloading other structures, particularly the internal cortical layer.
引用
收藏
页码:1295 / 1301
页数:7
相关论文
共 50 条
  • [31] The predictors of implant failure after maxillary sinus floor augmentation and reconstruction: a retrospective study of 1045 consecutive implants
    Zinser, Max J.
    Randelzhofer, Peter
    Kuiper, Luit
    Zoeller, Joachim E.
    De Lange, Gert L.
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 115 (05): : 571 - 582
  • [32] Making bone: implant insertion into tissue-engineered bone for maxillary sinus floor augmentation - a preliminary report
    Schmelzeisen, R
    Schimming, R
    Sittinger, M
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2003, 31 (01) : 34 - 39
  • [33] Histologic Changes in the Sinus Membrane after Maxillary Sinus Augmentation with Simultaneous Implant Placement Using Engineered Bone Graft Material
    陆家瑜
    赵伟
    朱红
    瞿晓辉
    邹德荣
    Journal of Shanghai Jiaotong University(Science), 2011, 16 (03) : 380 - 384
  • [34] Histologic changes in the sinus membrane after maxillary sinus augmentation with simultaneous implant placement using engineered bone graft material
    Lu J.-Y.
    Zhao W.
    Zhu H.
    Qu X.-H.
    Zou D.-R.
    Journal of Shanghai Jiaotong University (Science), 2011, 16 (3) : 380 - 384
  • [35] Maxillary Sinus Floor Augmentation Using an Equine-Derived Graft Material: Preliminary Results in 17 Patients
    Rivara, F.
    Negri, M.
    Lumetti, S.
    Parisi, L.
    Toffoli, A.
    Calciolari, E.
    Manfredi, E.
    Macaluso, G. M.
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [36] Maxillary Sinus Floor Augmentation Using Blood Without Graft Material. Preliminary Results in 10 Patients
    de Oliveira, Greison R.
    Olate, Sergio
    Cavalieri-Pereira, Lucas
    Pozzer, Leandro
    Asprino, Luciana
    de Moraes, Marcio
    de Albergaria-Barbosa, Jose Ricardo
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (10) : 1670 - 1675
  • [37] Osteoinductive calcium phosphate with submicron topography as bone graft substitute for maxillary sinus floor augmentation: A translational study
    van Dijk, Lukas A. A.
    Janssen, Nard G. G.
    Nurmohamed, Silke J. J.
    Muradin, Marvick S. M.
    Longoni, Alessia
    Bakker, Robbert C. C.
    de Groot, Florence G.
    de Bruijn, Joost D. D.
    Gawlitta, Debby
    Rosenberg, Antoine J. W. P.
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (03) : 177 - 195
  • [38] Maxillary Sinus Floor Elevation Combined With a Vertical Onlay Graft
    Shibuya, Yasuyuki
    Takeuchi, Yuka
    Asai, Tomoko
    Takeuchi, Junichiro
    Suzuki, Hiroaki
    Komori, Takahide
    IMPLANT DENTISTRY, 2012, 21 (02) : 91 - 96
  • [39] Intraoral Approach for Sinus Graft Infection Following Lateral Sinus Floor Augmentation With Simultaneous Implant Placement: A Clinical Case Series
    Park, Won-Bae
    Kang, Kyung Lhi
    Han, Ji-Young
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (03) : 253 - 262
  • [40] Evaluation of a Maxillary Sinus Floor Augmentation in the Presence of a Large Antral Pseudocyst
    Gonzalez Cortes, Arthur Rodriguez
    Correa, Luciana
    Arita, Emiko Saito
    JOURNAL OF CRANIOFACIAL SURGERY, 2012, 23 (06) : E535 - E537