共 22 条
Application of novel Modified Biological Aerated Filter (MBAF) as a promising post-treatment for water reuse: Modification in configuration and backwashing process
被引:8
|作者:
Nikoonahad, Ali
[1
,2
]
Ghaneian, Mohammad Taghi
[1
]
Mahvi, Amir Hossein
[3
,4
]
Ehrampoush, Mohammad Hassan
[1
]
Ebrahimi, Ali Asghar
[1
]
Lotfi, Mohammad Hassan
[5
]
Salamehnejad, Sima
机构:
[1] Shahid Sadoughi Univ Med Sci, Environm Sci & Technol Res Ctr, Dept Environm Hlth Engn, Yazd, Iran
[2] Ilam Univ Med Sci, Sch Hlth, Dept Environm Hlth Engn, Ilam, Iran
[3] Univ Tehran Med Sci, CSWR, IER, Tehran, Iran
[4] Univ Tehran Med Sci, Sch Publ Hlth, Tehran, Iran
[5] Shahid Sadoughi Univ Med Sci, Hlth Fac, Dept Biostat & Epidemiol, Yazd, Iran
关键词:
BAF;
Water reuse;
Advanced wastewater treatment;
Polystyrene coated by sand (PCS) media;
PHOSPHORUS REMOVAL;
BAF;
NITROGEN;
PERFORMANCE;
FILTRATION;
MEDIA;
TECHNOLOGY;
EFFLUENT;
SEWAGE;
D O I:
10.1016/j.jenvman.2017.07.062
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
Biological Aerated Filter (BAF) reactors due to their plentiful biomass, high shockability, high efficiency, good filtration, availability and lack of need for large land areas, are enjoying from great importance in advanced wastewater treatment. Therefore, in this study, Polystyrene Coated by Sand (PCS) was produced as a novel media and its application in a modified down-flow BAF structure for advanced wastewater treatment was assessed in two steps. In step one, the backwash effluent did not return to the system, while in step two backwash effluent returned to increase the water reuse efficiency. The backwash process was also studied through three methods of Top Backwashing (TB), Bottom Backwashing (BB), as well as Top and Bottom Backwashing Simultaneously (TBBS). The results showed that return of backwash effluent had no significant effect on the BAF effluent quality. In the second step similar to the first one with slight differences, the residual average concentrations of TSS, BOD5, and COD at the effluent were about 2.5, 8.2, and 25.5 mg/L, respectively. Additionally, in step two, the mean volume of disposal sludge/volume of treated water (v(ds)/v(tw)) decreased a large extent to about 0.088%. In other words, the water reuse has increased to more than 99.91%. The backwash time in methods of TB and BB were 65 and 35 min, respectively; however, it decreased in TBBS methods to 25 min. The concentrations of most effluent parameters in this system are in concordance with the 2012 EPA Agriculture Standards, even for irrigation of Non-processed agricultural crops and livestock water consumption. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:191 / 199
页数:9
相关论文