Improvement of the TDR/TDT measurement using deconvolution technique in LabView

被引:0
|
作者
Lesnikowski, Jacek [1 ]
机构
[1] Tech Univ Lodz, Katedra Odziezownictwa & Tekstroniki, PL-90924 Lodz, Poland
来源
PRZEGLAD ELEKTROTECHNICZNY | 2011年 / 87卷 / 03期
关键词
reflektometry; transmission lines; deconvolution;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
TDR/TDT (time domain reflektometry/time domain transmission) technique is one of the most common method for evaluating a transmission lines, connectors etc. The paper is intended for users who want to create or improve a TDR/TDT system based on the user-owned digital oscilloscope, pulse generator and popular LabView program. The paper presents a practical application of deconvolution technique used in TDR/TDT measurements. This technique is used to improve the overall resolution and accuracy of TDR/TDT measurement results. The first part of the paper presents a theoretical introduction to a deconvolution technique. The second part describes practical implementation of the deconvolution procedure using the popular measurement program LabView. Finally, the application of the described deconvolution procedure, in the real system for the measurement of a new type of textile transmission lines applicable in Textronics, is presented.
引用
收藏
页码:274 / 276
页数:3
相关论文
共 50 条
  • [31] Simultaneous measurement of dielectric properties and levels of liquids using a TDR method
    Cataldo, A.
    Tarricone, L.
    Attivissimo, F.
    Trotta, A.
    [J]. MEASUREMENT, 2008, 41 (03) : 307 - 319
  • [32] WATER CONTENT MEASUREMENT OF BUILDING MATERIALS USING SURFACE TDR PROBE
    Suchorab, Zbigniew
    Zelazna, Agnieszka
    Sobczuk, Henryk
    [J]. ECOLOGICAL CHEMISTRY AND ENGINEERING A-CHEMIA I INZYNIERIA EKOLOGICZNA A, 2011, 18 (07): : 877 - 886
  • [33] Separation measurement of parasitic inductance and stray capacitance using the TDR method
    Tokyo Metropolitan University, 1-1, Minamiosawa, Hachioji, Tokyo 192-0397, Japan
    [J]. IEEJ Trans. Ind Appl., 4 (443-449):
  • [34] Reflectivity function reconstruction using the frequency deconvolution technique
    M. G. S. Ali
    N. Z. Elsayed
    [J]. Acoustical Physics, 2013, 59 : 580 - 583
  • [35] Reflectivity function reconstruction using the frequency deconvolution technique
    Ali, M. G. S.
    Elsayed, N. Z.
    [J]. ACOUSTICAL PHYSICS, 2013, 59 (05) : 580 - 583
  • [36] A deconvolution technique using optimal Wiener filtering and regularization
    Sekko, E
    Thomas, G
    Boukrouche, A
    [J]. SIGNAL PROCESSING, 1999, 72 (01) : 23 - 32
  • [37] Deconvolution of lidar signal using matrix operation technique
    Park, YJ
    Kong, HJ
    [J]. 17TH CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: OPTICS FOR SCIENCE AND NEW TECHNOLOGY, PTS 1 AND 2, 1996, 2778 : 1000 - 1001
  • [38] Improvement in hydrogen measurement technique for molten aluminum
    Gansemer, Todd M.
    Reynolds, Brian C.
    Hart, Jim N.
    Chesonis, D. Corleen
    [J]. LIGHT METALS 2007, 2007, : 685 - +
  • [39] IMPROVEMENT OF AUTOMATIZED FLUOROMETRIC TECHNIQUE OF HISTAMINE MEASUREMENT
    RUFF, F
    SANTAIS, MC
    FOUSSARD, C
    PARROT, JL
    [J]. AGENTS AND ACTIONS, 1977, 7 (01): : 122 - 123
  • [40] IMPROVEMENT OF RADIONUCLIDE LEFT TO RIGHT SHUNTQUANTITATION USING DECONVOLUTION ANALYSIS
    HAM, HR
    DOBBELEIR, A
    VIART, P
    PIEPSZ, A
    LENAERS, A
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1980, 5 (03): : A24 - A24