Numerical Study on the Impact of Platform Screen Doors in a Subway Station with a Train on Fire

被引:3
|
作者
Teodosiu, Catalin Ioan [1 ]
Kubinyecz, Vladimir Francisc [1 ]
机构
[1] Tech Univ Civil Engn Bucharest, CAMBI Res Ctr, Bucharest 021414, Romania
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 16期
关键词
Computational Fluid Dynamics (CFD) modeling; subway fire; emergency ventilation; Platform Screen Doors (PSDs); VENTILATION MODE; CFD SIMULATION; SMOKE CONTROL; TUNNEL; OPTIMIZATION; EMERGENCY; SYSTEMS; PREDICTION; SUICIDES; VELOCITY;
D O I
10.3390/app12168296
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Featured Application Numerical data for validating emergency strategy concerning trains on fire stopped at the platform of subway stations equipped with a Platform Screen Door system. Almost all recently built subway stations are equipped with Platform Screen Doors (PSDs) due to the numerous proven benefits of these systems. In addition, PSDs are now being introduced in existing subway stations, but their operation in conjunction with previously designed ventilation systems in case of emergency should be deeply studied. In this context, the objective of this study is to assess the efficiency of the planned emergency strategy (coupled operation, ventilation systems-PSDs system) in the case of trains on fire stopped at the platform of a subway station retrofitted with PSDs. The approach is based on Computational Fluid Dynamics (CFD) full-scale simulations to predict the airflow, temperature, and pollutant (carbon monoxide-CO and carbon dioxide-CO2) concentrations caused by the fire. The results show the evident contribution of PSDs in stopping the dispersion of hot and polluted air in the subway station during the entire simulation time (20 min from the arrival of the train on fire). Consequently, the investigated emergency strategy (exhausting air both through the "over track system" and the "under platform system", simultaneously with the opening of the PSDs on the side with the train on fire) assures the safe evacuation of passengers as soon as they have left the subway train. The results indicate that access to the platform is not perturbed by high temperatures or dangerous concentrations of CO and CO2.
引用
收藏
页数:29
相关论文
共 50 条
  • [11] CFD simulation of a vehicle fire in a station equipped with platform screen doors
    Miclea, PC
    McKinney, DM
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON AERODYNAMICS AND VENTILATION OF VEHICLE TUNNELS: PRINCIPLES, ANALYSIS AND DESIGN, 2000, (43): : 305 - 322
  • [12] Experimental Investigation of Air Quality in a Subway Station with Fully Enclosed Platform Screen Doors
    Pang, Liping
    Yang, Chenyuan
    Cao, Xiaodong
    Tian, Qing
    Li, Bo
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (14) : 1 - 15
  • [13] Monitoring the Gaps between the Platform Screen Doors and the Doors of Subway Train Based on Optical Time Domain Reflectrometer
    Zhang, Hongtao
    Wei, Zhanxiong
    Wang, Pengfei
    Fan, LingLing
    Guan, Liang
    Zhao, Qiming
    Cui, Hong-Liang
    [J]. FIBER OPTIC SENSORS AND APPLICATIONS VII, 2010, 7677
  • [14] Simulation study on air leakage of platform screen doors in subway stations
    Li, Xiaofeng
    Wang, Ying
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2018, 43 : 350 - 356
  • [15] Unorganized ventilation in subway stations with Platform Screen Doors
    Wang, Ying
    Li, Xiaofeng
    [J]. BUILDING AND ENVIRONMENT, 2017, 125 : 556 - 564
  • [16] Numerical study on the optimization of smoke ventilation mode at the conjunction area between tunnel track and platform in emergency of a train fire at subway station
    Meng, Na
    Hu, Longhua
    Wu, Long
    Yang, Lizhong
    Zhu, Shi
    Chen, Longfei
    Tang, Wei
    [J]. TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2014, 40 : 151 - 159
  • [17] Installation of platform screen doors and their impact on indoor air quality: Seoul subway trains
    Son, Youn-Suk
    Jeon, Jae-Sik
    Lee, Hyung Joo
    Ryu, In-Cheol
    Kim, Jo-Chun
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2014, 64 (09) : 1054 - 1061
  • [18] A Noticeable Change in Indoor Radon Levels After Platform Screen Doors Installation in Seoul Subway Station
    Jeon, Jae-Sik
    Yoon, Jong-Cheol
    Lee, Ho-Chan
    Eom, Seok-Won
    Chae, Young-Zoo
    [J]. JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2012, 28 (01) : 59 - 67
  • [19] Study on disaster prevention in case of fire at subway platform with platform screen door
    Rie, DH
    Yoon, SW
    Ko, JW
    Lee, KO
    [J]. PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL V, PTS A AND B, 2005, 5 : 921 - 927
  • [20] FIELD EXPERIMENT OF TRAIN-INDUCED WIND PRESSURE ON PLATFORM SCREEN DOOR AT SUBWAY STATION
    Kim, Jung-Yup