摘要
Objective. The aim of this work is an AI based approach to reduce the volume effect of ionization chambers used to measure high energy photon beams in radiotherapy. In particular for profile measurements, the air-filled volume leads to an inaccurate measurement of the penumbra. Approach. The AI-based approach presented in this study was trained with synthetic data intended to cover a wide range of realistic linear accelerator data. The synthetic data was created by randomly generating profiles and convolving them with the lateral response function of a Semiflex 3D ionization chamber. The neuronal network was implemented using the open source tensorflow.keras machine learning framework and a U-Net architecture. The approach was validated on three accelerator types (Varian TrueBeam, Elekta VersaHD, Siemens Artiste) at FF and FFF energies between 6 MV and 18 MV at three measurement depths. For each validation, a Semiflex 3D measurement was compared against a microDiamond measurement, and the AI processed Semiflex 3D measurement was compared against the microDiamond measurement. Main results. The AI approach was validated with dataset containing 306 profiles measured with Semiflex 3D ionization chamber and microDiamond. In 90% of the cases, the AI processed Semiflex 3D dataset agrees with the microDiamond dataset within 0.5 mm/2% gamma criterion. 77% of the AI processed Semiflex 3D measurements show a penumbra difference to the microDiamond of less than 0.5 mm, 99% of less than 1 mm. Significance. This AI approach is the first in the field of dosimetry which uses synthetic training data. Thus, the approach is able to cover a wide range of accelerators and the whole specified field size range of the ionization chamber. The application of the AI approach offers an quality improvement and time saving for measurements in the water phantom, in particular for large field sizes.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] On beam quality and flatness of radiotherapy megavoltage photon beams
    Hossain, Murshed
    Rhoades, Jeffrey
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (01) : 135 - 145
  • [2] THE PROBLEMS AND PERSPECTIVES OF MEGAVOLTAGE PHOTON BEAM RADIOTHERAPY IN UKRAINE
    Starenkiy, V. P.
    Vasyliev, L. L.
    Samofalov, I. O.
    [J]. PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2016, (05): : 94 - 97
  • [3] On beam quality and flatness of radiotherapy megavoltage photon beams
    Murshed Hossain
    Jeffrey Rhoades
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 135 - 145
  • [4] Monte Carlo source model for megavoltage photon-beam radiotherapy: Photon source characteristics
    Fix, M
    Keall, P
    Libby, B
    Mohan, R
    Siebers, J
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1904 - 1904
  • [5] Artificial Neural Network Model for Spectral Construction of A Linear Accelerator Megavoltage Photon Beam
    Hussain, Sabir
    [J]. UKSIM-AMSS FIRST INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS, MODELLING AND SIMULATION, 2010, : 86 - 91
  • [6] A review of artificial intelligence applications for motion tracking in radiotherapy
    Mylonas, Adam
    Booth, Jeremy
    Nguyen, Doan Trang
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2021, 65 (05) : 596 - 611
  • [7] Overview of artificial intelligence-based applications in radiotherapy: Recommendations for implementation and quality assurance
    Vandewinckele, Liesbeth
    Claessens, Michael
    Dinkla, Anna
    Brouwer, Charlotte
    Crijns, Wouter
    Verellen, Dirk
    van Elmpt, Wouter
    [J]. RADIOTHERAPY AND ONCOLOGY, 2020, 153 : 55 - 66
  • [8] Recent Applications of Artificial Intelligence in Radiotherapy: Where We Are and Beyond
    Santoro, Miriam
    Strolin, Silvia
    Paolani, Giulia
    Della Gala, Giuseppe
    Bartoloni, Alessandro
    Giacometti, Cinzia
    Ammendolia, Ilario
    Morganti, Alessio Giuseppe
    Strigari, Lidia
    [J]. APPLIED SCIENCES-BASEL, 2022, 12 (07):
  • [9] Artificial intelligence uncertainty quantification in radiotherapy applications - A scoping review
    Wahid, Kareem A.
    Kaffey, Zaphanlene Y.
    Farris, David P.
    Humbert-Vidan, Laia
    Moreno, Amy C.
    Rasmussen, Mathis
    Rend, Jintao
    Naser, Mohamed A.
    Netherton, Tucker J.
    Korreman, Stine
    Balakrishnan, Guha
    Fuller, Clifton D.
    Fuentes, David
    Dohopolski, Michael J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2024, 201
  • [10] Applications of artificial intelligence and deep learning in molecular imaging and radiotherapy
    Arabi, Hossein
    Zaidi, Habib
    [J]. EUROPEAN JOURNAL OF HYBRID IMAGING, 2020, 4 (01):